Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Fisioter. mov ; 27(4): 565-572, Oct-Dec/2014. tab
Artigo em Inglês | LILACS | ID: lil-732492

RESUMO

Introduction Knees osteoarthritis (OA) is a complex degenerative disease with intra-articular changes affecting the amplitude of the quadriceps angle (Q). To measure this variable, it is necessary to use reliable protocols aiming at methodological reproducibility. The objective was to evaluate the intra-examiner and inter-examiner reliability of clinical and radiographic measures of the Q angle and to investigate the relationship between the degree of OA and the magnitude of this angle in the elderly. Materials and methods 23 volunteers had the Q angle measured by two evaluators at 48-h interval. Clinical measurements were collected by using the universal goniometer in the same position adopted in the radiographic examination. Results The intra-examiner reliability was good (0.722 to 0.763) for radiographic measurements and low (0.518 to 0.574) for clinical assessment, while inter-examiner reliability was moderate (0.634) for radiographic measurements and low (0.499) to the clinics. The correlation analysis between the radiographic values with the OA classification showed no correlation between them (p = 0.824 and r = -0.024). Conclusion Clinically, it is suggested that the radiographic examination is preferable to evaluate the Q angle of elderly women with knee osteoarthritis. Moreover, the magnitude of this angle did not correlate with the degree of impairment of OA in this population.


Introdução A osteoartrite (OA) de joelhos é uma doença degenerativa complexa com alterações intra-articulares que comprometem a amplitude do ângulo do quadríceps (Q). Para mensuração dessa variável, é necessária a utilização de protocolos que apresentem confiabilidade, visando reprodutibilidade metodológica. Objetivo Avaliar a confiabilidade intra e interexaminadores das medidas clínicas e radiográficas do ângulo Q e verificar se existe relação entre o grau de OA e a magnitude deste ângulo em idosas. Materiais e métodos 23 voluntárias, tiveram o ângulo Q mensurado por 2 avaliadores, com intervalo de 48 horas. As medidas clínicas foram coletadas por meio do goniômetro universal na mesma posição adotada no exame radiográfico. Resultados A confiabilidade intraexaminador foi boa (0,722–0,763) nas medidas radiográficas e baixa (0,518–0,574) nas medidas clínicas, enquanto a confiabilidade interexaminadores foi moderada (0,634) nas medidas radiográficas e baixa (0,499) nas clínicas. A análise da correlação entre os valores radiográficos com a classificação da OA não demonstrou correlação entre os mesmos (p = 0,824 e r = -0,024). Conclusão Clinicamente, sugere-se que o exame radiográfico seja preferível para avaliação do ângulo Q de idosas com OA de joelhos. Além disto, a magnitude deste ângulo não se relacionou com o grau de acometimento da OA nesta população.

2.
Arq. ciências saúde UNIPAR ; 16(2): 93-98, maio-ago. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-737271

RESUMO

A silicose representa um importante problema de saúde pública em todo o mundo, sobretudo nos países em desenvolvimento, sendo a principal causa de invalidez entre as doenças respiratórias ocupacionais. É uma pneumoconiose fibrótica, irreversível e potencialmente fatal, causada pela inalação de poeira contendo sílica cristalina. O diagnóstico é estabelecido através da história clínica e ocupacional de exposição à sílica, na presença de alterações radiológicas. Estudos experimentais e clínicos sugerem que a inalação da poeira da sílica está associada a um processo inflamatório pulmonar e sistêmico, mesmo em indivíduos que não desenvolveram silicose. Até o momento não existem exames laboratoriais específicos para o diagnóstico da doença, de modo que o conhecimento de marcadores biológicos associados à imunopatologia da silicose pode ser importante na detecção precoce da instalação e desenvolvimento da doença. O presente artigo traz uma revisão de estudos que investigaram os possíveis biomarcadores inflamatórios da doença no sangue e no lavado bronco-alveolar de humanos e de modelos experimentais.


Silicosis is an important public health problem worldwide, especially in developing countries and is the leading cause of disability among occupational respiratory diseases. It is a fibrotic disease irreversible and potentially fatal caused by inhaling dust containing crystalline silica, the most frequent type of pneumoconiosis. Diagnosis is established by clinical and occupational history of exposure to silica, in the presence of radiological changes. Experimental and clinical studies suggest that inhalation of silica dust is associated with pulmonary and systemic inflammation even in patients who did not develop silicosis. There are no specific tests for the routine laboratory diagnosis of the disease and the study of biological markers associated with the immunopathology of silicosis is important to understanding the establishment and development of silicosis. This article presents a review of studies investigating the possible inflammatory biomarkers of disease in blood and bronchoalveolar lavage from humans and experimental models.


Assuntos
Humanos , Silicose , Saúde Pública , Citocinas , Quimiocinas , Sistema Imunitário
3.
Acta fisiátrica ; 18(1): 16-20, mar. 2011.
Artigo em Português | LILACS | ID: lil-663371

RESUMO

O limiar de lactato (LL) é utilizado como um marcador da acidose metabólica e representa o momento durante o exercício em que o lactato sanguíneo começa aumentar de forma exponencial. Este LL tem sido utilizado como medidor de condicionamento físico, indicador sensível do estado do treinamento aeróbico em sujeitos saudáveis e doentes, além disso, auxilia na identificação do estímulo de treinamento ideal e na prescrição da intensidade de treinamento. O objetivo do presente estudo foi avaliar a confiabilidade intra e interexaminadores das medidas do LL obtidas através do método de detecção visual. Para isso, 31 voluntárias do sexo feminino (67,50 ± 4,41 anos; 1,52 ± 0,07 m; 64,55 ± 11,46 kg), aparentemente saudáveis e no período pós-menopausa, participaram do estudo. O LL foi determinado a partir de um teste realizado na esteira ergométrica até a fadiga, que consistiu de estágios com carga progressiva (variação da velocidade e/ou inclinação). Amostras de sangue foram coletadas por meio de uma punção na polpa digital do dedo médio a cada 3 minutos durante o teste. Em seguida, foram construídos os gráficos do método de detecção visual (software Prisma5) a partir da concentração de lactato sanguíneo coletado a cada estágio do exercício (intervalo de 3 minutos) em função da taxa de trabalho correspondente ao consumo de oxigênio (VO2) estimado durante o teste na esteira. A análise estatística foi realizada através do Coeficiente de Correlação Intraclasse (CCI). A confiabilidade intraexaminador foi excelente (0,950 - 0,952) e a confiabilidade interexaminadores foi boa (0,789 - 0,770). Dessa forma,sugere-se que o método de detecção visual é uma forma segura e confiável para detectar o LL na prática clínica e em pesquisas.


The lactate threshold (LT) is used as a marker for metabolic acidosis and represents the time during the exercise in which blood lactate begins to increase exponentially. LT has been used as a measurer of physical capacity,a sensitive indicator of the state of aerobic training in healthy and sickpatients, in addition, assists in identifying the optimal training stimulus and the prescription of training intensity. The aim of this study was to evaluate the reliability, intra and interrater, of the LT obtained by a visual detection method. For this, 31 female volunteers (67.50 ± 4.41 years, 1.52± 0.07 m, 64.55 ± 11.46 kg), apparently healthy and postmenopausal, participated in the study. The LT was determined from a test performed on a treadmill, which consisted of stages with progressive workload(variation of speed and/or incline), until the patient experienced fatigue. Blood samples were collected from a finger prick of the middle finger every 3 minutes during the test. Next, the visual detection method graphics were constructed (software Prisma5) from the blood lactate concentration collected at each stage of exercise (3 minute intervals) depending on the work rate corresponding to oxygen consumption (VO2) estimated during the treadmill test. Statistical analysis was performed by the intraclass correlation coefficient (ICC). Intrarater reliability was excellent (0.950- 0.952) and interrater reliability was good (0.789 - 0.770). Thus, it has been determined that the visual detection method is a safe and reliable way to detect the LT in clinical practice and research.


Assuntos
Humanos , Feminino , Exercício Físico/fisiologia , Limiar Anaeróbio/fisiologia , Reprodutibilidade dos Testes , Teste de Esforço , Visão Ocular , Ácido Láctico/sangue , Interpretação Estatística de Dados
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA