Medical Principles and Practice. 2008; 17 (2): 149-153
em Inglês | IMEMR | ID: emr-88978

RESUMO

This study aimed at determining the effects of cigarette smoking based on gender, on several hematological parameters and von Willebrand factor protein in the asymptomatic Arab population of Kuwait. Ninety-two subjects participated in this study: 55 males [31 smokers and 24 nonsmokers] and 37 females [18 smokers and 19 nonsmokers]. Complete blood count results were obtained using Beckman Coulter Hematology Analyzer. Von Willebrand factor functional activity was determined using an enzyme-linked immunoassay-based test in which anti-von Willebrand factor IgG monoclonal antibody was used that recognizes a functional epitope of the protein. The coagulation profile was obtained using ACL[R] 9000 coagulation analyzer. Male smokers had significantly higher levels of white blood cell count [p = 0.03] and von Willebrand factor protein levels [p = 0.029], and a significantly shorter thrombin time [p = 0.019] than nonsmokers. Smoking did not appear to affect any of the parameters analyzed in females as no significant difference was found between smokers and nonsmokers [p > 0.05]. Our results showed that smoking affected white blood cell count and von Willebrand factor levels in males and not in females, and as such could be potential markers for smoking-induced endothelial damage in asymptomatic Arab male smokers


Assuntos
Humanos , Masculino , Feminino , Hematologia , Fator de von Willebrand , Árabes , Identidade de Gênero , Contagem de Leucócitos , Contagem de Plaquetas , Tempo de Protrombina , Tempo de Tromboplastina Parcial , Tempo de Trombina
2.
Medical Principles and Practice. 2005; 14 (4): 241-244
em Inglês | IMEMR | ID: emr-73539

RESUMO

To compare the performance of SEDIsystem[TM], a fully automated analyzer for the measurement of the erythrocyte sedimentation rate [ESR], with the manual Westergren method. Materials and Both methods were applied to 150 randomly selected subjects. The linear regression and Bl and and Altman data analysis methods were used to measure the agreement between the automated and manual methods. The regression analysis showed a good correlation between the two methods [r = 0.91]. The Bl and and Altman data analysis showed no systematic bias [95% confidence interval for mean difference]; however, limits of agreement were between 11.52 and -37.88. This indicates that ESR values measured by the SEDIsystem may be 11.52 mm/h above or 37.88 mm/h below the reference method. A greater scatter of data was also observed with abnormally high [>25mm/h] ESR results [mean of difference = -21.4 and limits of agreement = -45.2 and 2.26] compared with normal [<25 mm/h] readings [mean of difference =-3.9 and limits of agreement =-13.5 and 5.7]. The Bl and and Altman statistical analysis showed a wide degree of scatter between results obtained by the two ESR techniques that was not clearly demonstrated using the linear regression analysis. The automated system was found to underestimate ESR with the Bl and and Altman statistical analysis, and therefore a correction factor is recommended


Assuntos
Humanos , Hematologia/métodos , Hematologia/instrumentação , Eritrócitos , Métodos