Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J. pediatr. (Rio J.) ; 97(6): 610-616, Nov.-Dec. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1350970

RESUMO

Abstract Objectives: The objective was to calculate weight/length (W/L) ratio values and percentiles by sex and gestational age (GA) to estimate fat mass (FM), fat-free mass (FFM) and body fat percentage (BF%) as well as to compare these indices in preterm, small (SGA), and large (LGA) for GA, stunted and wasted infants from a Brazilian cohort of newborns, comparing with the INTERGROWTH-21st. Methods: Secondary, cross-sectional analysis of data obtained of 7427 live-born infants from the BRISA Cohort Study in the city of Ribeirão Preto, SP, Brazil in 2010. For body composition estimation, W/L ratio was used in multiple regression models. The 3rd, 50th, and 97th percentiles for W/L ratio and body composition measures (FM, FFM, and BF%) were calculated using fractional polynomial regression models. Results: Average W/L ratio was 6.50 kg/m (SD 0.87), while for FM, BF%, and FFM the corresponding values were 359.64 g (145.76), 10.90% (3.05) and 2798.84 g (414.84), respectively. SGA (< 3rd percentile), and wasted infants showed the lowest W/L ratios and measures of body composition. The 3rd, 50th, and 97th percentiles charts of W/L, FM, BF%, and FFM by GA and sex are presented. Conclusions: W/L ratio values of the RP-BRISA Cohort are higher than IG-21st. SGA (< 3rd) and wasted infants showed the lowest W/L ratio and measures of body composition. The body composition references presented here could be used to refine the nutritional assessment of Brazilian newborns and to facilitate comparisons across populations.


Assuntos
Humanos , Recém-Nascido , Lactente , Composição Corporal , Brasil , Estudos Transversais , Estudos de Coortes , Idade Gestacional
2.
J. pediatr. (Rio J.) ; 96(4): 511-519, July-Aug. 2020. tab, graf
Artigo em Inglês | LILACS, ColecionaSUS, SES-SP | ID: biblio-1135049

RESUMO

Abstract Objectives: (a) To determine the 3rd, 50th, and 97th percentiles of weight, length, and head circumference of newborns from the Ribeirão Preto BRISA cohort, according to gender and gestational age, and compare them with the Intergrowth-21st standard; (b) To estimate the small for gestational age ( < 3rd percentile), large for gestational age ( > 97th percentile), stunting (length < 3rd percentile), and wasting (body mass index < 3rd percentile). Methods: Observational study of a cohort of 7702 newborns between 01/01/2010 and 12/31/2010 in the city of Ribeirão Preto, SP, Brazil. The 3rd, 50th, and 97th percentiles were determined for the anthropometric measurements using fractional polynomial regression. Results: The weight difference between Ribeirão Preto and Intergrowth-21st was small, being more pronounced in preterm infants (mean difference between the two populations of +266 g); for full-term newborns, there was a mean difference of +66 g, and for post-term infants, of -113 g. For length, the mean variation was always <1 cm; whereas for head circumference, preterm newborns showed a variation >1 cm, and full-term and post-term newborns showed a variation of <1 cm. The small and large for gestational age detection rates were 2.9% and 4.3%, respectively. Stunting affected 6.5% of all newborns and wasting, 1.5%, with a predominance in girls and in full-term pregnancies; both conditions were present in 0.4% of the sample. Conclusions: Newborns from Ribeirão Preto, when compared to the Intergrowth-21 standard, are heavier, longer, and have a larger head circumference until they reach full-term.


Resumo Objetivos: Determinar os percentis 3, 50 e 97 de peso, comprimento e perímetro cefálico de recém-nascidos da Coorte BRISA Ribeirão Preto, segundo sexo e idade gestacional, e comparar com o padrão Intergrowth-21st; b) Estimar os fenótipos pequeno para idade gestacional (< percentil 3), grande para idade gestacional (> percentil 97), stunting (comprimento < percentil 3) e waisting (índice de massa corporal < percentil 3). Método: Estudo observacional de uma coorte de 7.702 recém-nascidos entre 01/01 e 31/12/2010 na cidade de Ribeirão Preto, SP, Brasil. Os percentis 3, 50 e 97 para as medidas antropométricas foram determinados com regressão polinomial fracionária. Resultados: A diferença de peso entre Ribeirão Preto e Intergrowth-21st foi pequena, mais acentuada nos recém-nascidos pré-termo (diferença média entre as duas populações foi de + 266 gramas); para os recém-nascidos a termo a diferença média foi de + 66 gramas e para os pós-termo de -113 gramas. Para comprimento, a variação média foi sempre < 1 cm; enquanto que para perímetro cefálico os recém-nascidos pré-termo apresentaram variação > 1 cm e os recém-nascidos a termo e pós-termo tiveram variação < 1 cm. As taxas de detecção de pequeno e grande para idade gestacional foram 2,9% e 4,3%, respectivamente. Stunting afetou 6,5% de todos os recém-nascidos e waisting 1,5%, com predomínio em meninas e em gestações a termo; ambas as condições estavam presentes em 0,4% da amostra. Conclusões: Os recém-nascidos de Ribeirão Preto, quando comparados com o padrão Intergrowth-21st, apresentam-se mais pesados, mais longos e com maior circunferência craniana até chegarem a termo.


Assuntos
Humanos , Feminino , Gravidez , Recém-Nascido , Recém-Nascido Prematuro , Peso ao Nascer , Estatura , Brasil/epidemiologia , Cefalometria , Idade Gestacional , Cabeça
3.
Medicina (Ribeiräo Preto) ; 50(1): 66-75, jan.-fev. 2017. ilus
Artigo em Português | LILACS | ID: biblio-833852

RESUMO

Health institutions, particularly hospitals, are characterized as complex structures that need managers with a global view of the institution and its relations with the external environment. The hospital pharmacy is a strategic unit, which cooperates with the institutional management and integrates the multiprofessional team in the process related to the acquisition, provision and control of essential inputs for the inpatient care process. The objective in this study is to demonstrate the applicability, in the context of hospital-based health, of a performance measuring system at the pharmacy. Method: A descriptive and longitudinal study was undertaken on the evolution of the key indicator Absence Rate of Standardized Drugs in inpatient care between March 2004 and December 2013. This indicator was employed to monitor the impact of changes the Pharmacy Division has been implementing, as the first step of the pharmaceutical care cycle in the model of the process-based managed approach at a public university hospital. Qualitative data collection methods were used, including observation and documentary analysis, as well as quantitative data collection. Results: After the application of the model, one point of change in the key performance indicator was detected in the tenth month, when the process-based management model was implemented at the pharmacy. Conclusions: The process-based management approach was effective for the hospital pharmacy. The premise adopted is that the administrative changes (interferences), focused on the improvement of the processes and the selection and monitoring of indicators, influence the processes, reducing the variability and improving the quality (AU)


As instituições de saúde, especialmente hospitais, são caracterizadas como estruturas complexas que precisam de administradores com uma visão global da instituição e de suas relações com o ambiente externo. A farmácia hospitalar é uma unidade estratégica, que colabora com a administração institucional e integra a equipe multiprofissional no processo que tange a aquisição, provisão e controle de insumos essenciais para o processo do atendimento do paciente internado. Este estudo tem como objetivo demonstrar a aplicabilidade, no contexto da saúde hospitalar, de um sistema de medição de desempenho da farmácia. Método: Trata-se de um estudo descritivo, longitudinal, sobre a evolução do indicador chave Taxa de Falta de Medicamentos Padronizados na assistência do paciente internado, no período de março de 2004 a dezembro de 2013. Esse indicador foi empregado para monitoramento do impacto de mudanças que a Divisão de Farmácia vem implementando, como primeira etapa do ciclo de assistência farmacêutica dentro do modelo da abordagem de gestão por processos, em um hospital público universitário. Foram usados métodos de coleta de dados qualitativos, incluindo a observação e análise documental, bem como coleta de dados quantitativos. Resultados: Após a aplicação do modelo, um ponto de mudança no indicador chave de desempenho, foi detectado no 10º mês, quando o modelo de gestão baseado em processo foi implementado na farmácia. Conclusões: A abordagem de gestão baseada em processos foi eficaz para a farmácia hospitalar. A premissa adotada é que as mudanças administrativas (interferências), com foco na melhoria dos processos e seleção e acompanhamento de indicadores, têm influencia sobre os processos, reduzindo a variabilidade e melhoria da qualidade (AU)


Assuntos
Serviço de Farmácia Hospitalar , Gestão da Qualidade Total , Indicadores de Gestão , Acessibilidade aos Serviços de Saúde
4.
Clinics ; 66(4): 641-648, 2011. ilus, tab
Artigo em Inglês | LILACS | ID: lil-588917

RESUMO

PURPOSE: To compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. INTRODUCTION: Many embolized aneurysms are subject to a recurrence of intra-aneurismal filling. Traditionally, imaging surveillance of coiled aneurysms has consisted of repeated digital subtraction angiography. However, this method has a small but significant risk of neurological complications, and many authors have advocated the use of noninvasive imaging methods for the surveillance of embolized aneurysms. METHODS: Forty-three aneurysms in 30 patients were studied consecutively between November 2009 and May 2010. Two interventional neuroradiologists rated the time-of-flight-magnetic resonance angiography, the contrast-enhanced-magnetic resonance angiography, and finally the digital subtraction angiography, first independently and then in consensus. The status of aneurysm occlusion was assessed according to the Raymond scale, which indicates the level of recanalization according to degrees: Class 1: excluded aneurysm; Class 2: persistence of a residual neck; Class 3: persistence of a residual aneurysm. The agreement among the analyses was assessed by applying the Kappa statistic. RESULTS: Inter-observer agreement was excellent for both methods (K = 0.93; 95 percent CI: 0.84-1). Inter-technical agreement was almost perfect between time-of-flight-magnetic resonance angiography and digital subtraction angiography (K = 0.98; 95 percent CI: 0.93-1) and between time-of-flight-magnetic resonance angiography and contrast-enhanced-magnetic resonance angiography (K = 0.98; 95 percent CI: 0.93-1). Disagreement occurred in only one case (2.3 percent), which was classified as Class I by time-of-flight-magnetic resonance angiography and Class II by digital subtraction angiography. The agreement between contrast-enhanced-magnetic resonance angiography and digital subtraction angiography was perfect (K = 1; 95 percent CI: 1-1). In three patients, in-stent stenosis was identified by magnetic resonance angiography but not confirmed by digital subtraction angiography. CONCLUSION: Digital subtraction angiography and both 3T magnetic resonance angiography techniques have excellent reproducibility for the assessment of aneurysms embolized exclusively with coils. In those cases also treated with stent remodeling, digital subtraction angiography may still be necessary to confirm eventual parent artery stenosis, as identified by magnetic resonance angiography.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angiografia Digital/métodos , Meios de Contraste , Embolização Terapêutica , Imageamento Tridimensional/métodos , Aneurisma Intracraniano/diagnóstico , Angiografia por Ressonância Magnética/métodos , Métodos Epidemiológicos , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Variações Dependentes do Observador , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA