Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. argent. cardiol ; 80(5): 341-346, oct. 2012. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-662170

RESUMO

Introducción El tracto de salida del ventrículo izquierdo (TSVI) suele estar implicado con relativa frecuencia en alteraciones anatómicas y anatomofuncionales, que son objeto de estudios. Sin embargo, su dinámica normal también es importante, en particular en procedimientos que involucran su área, y los nuevos métodos de imágenes tridimensionales permiten evaluarla. Objetivo Evaluar la dinámica del TSVI durante el ciclo cardíaco por ecocardiografía tridimensional transesofágica (eco 3D TE). Material y métodos Se incluyeron en forma prospectiva 42 pacientes derivados para ecocardiografía transesofágica. Los estudios se realizaron con sonda transesofágica tridimensional, con adquisiciones de volumen completo integradas por 4 latidos gatillados para análisis off-line. El ciclo cardíaco se dividió en protosístole (S1), mesosístole (S2) y telesístole (S3) y en protodiástole (D1), mesodiástole (D2) y telediástole (D3). El área del TSVI se estimó por planimetría del eje corto por cortes ortogonales al eje mayor del TSVI en cada fase. Resultados La edad media fue de 67 ± 10 años; el 63% eran hombres. El área del TSVI (cm2) en las diferentes fases del ciclo cardíaco fue: S1: 4,44 ± 1,02; S2: 4,15 ± 0,91; S3: 3,9 ± 0,89; D1: 3,76 ± 0,98; D2: 3,89 ± 1,04; D3: 4,34 ± 1,11. El área máxima se observó en S1, correspondiendo a la aposición de cierre de la valva anterior mitral (VaM) y escasa excursión del septum interventricular (SIV) hacia el TSVI; el área mínima se observó en D1 coincidiendo con cierta persistencia del SIV en el TSVI y la apertura máxima de la VaM ocupando parte del TSVI. La modificación total del área fue del 15% ± 11% (p < 0,0001), cambiando además de forma parcialmente elíptica o circular (sístole) a marcadamente elíptica o semilunar (diástole). Conclusión El TSVI presenta una variación en su área y su forma durante el ciclo cardíaco, con dependencia fundamentalmente del movimiento del SIV (en sístole) y de la apertura mitral (en diástole).


Assessment of Left Ventricular Outflow Tract Dynamics During the Cardiac cycle by Three-Dimensional Echocardiography Background Anatomical and anatomo-functional disorders of the left ventricular outflow tract (LVOT) are subject of numerous studies. However, LVOT normal dynamic behavior, especially in procedures involving this area is also relevant, and may be evaluated with new three-dimensional imaging methods. Objective The aim of this study was to assess LVOT dynamics during the cardiac cycle with three-dimensional transesophageal echocardiography (TEE). Methods Forty two patients referred for transesophageal echocardiography (TEE) were prospectively included. All TEE studies were performed with a three-dimensional transesophageal probe. For complete volume images, 4 gated beats were acquired for off-line analysis. The cardiac cycle was divided in proto-systole (S1), mid-systole (S2) and tele-systole (S3) and proto-diastole (D1), mid-diastole (D2) and tele-diastole (D3). The LVOT area was measured by planimetry of the short axis, through orthogonal sections to the long axis of the LVOT in each phase. Results Mean age was 67 ± 10 years, and 63% of the patients were male. The LVOT area (cm2) in the different phases of the cardiac cycle was: S1: 4.44 ± 1.02; S2: 4.15 ± 0.91; S3: 3.9 ± 0.89; D1: 3.76 ± 0.98; D2: 3.89 ± 1.04; D3: 4.34 ± 1.11. Maximum area was observed in S1, corresponding to the closed position of the anterior leaflet of the mitral valve (AL) and reduced motion of the interventricular septum (IVS) towards LVOT; minimum area was obtained in D1 consistent with a certain persistence of IVS in the LVOT and maximal AL opening occupying part of the LVOT. Total area reduction was 15 ± 11% (p<0.0001), changing the LVOT from a partially elliptical or circular shape (systole) to a markedly elliptical or semilunar one (diastole). Conclusion The LVOT changes its area and shape during the cardiac cycle, depending basically on the movement of the IVS (during systole) and mitral valve opening (during diastole).

2.
Rev. argent. cardiol ; 80(5): 387-389, oct. 2012. ilus
Artigo em Espanhol | LILACS | ID: lil-662178

RESUMO

El foramen oval permeable (FOP) es un defecto del septum interauricular que puede coexistir con aneurisma de éste y se asocia con pasaje de flujo de izquierda a derecha. Su presencia se ha vinculado con accidente cerebrovascular (ACV) embólico y con el síndrome de platipneaortodesoxia. En esta presentación se describe el caso de una paciente con síndrome de platipnea-ortodesoxia que representó un verdadero desafío diagnóstico, ya que ingresó a nuestra institución por neumonía y luego incidentalmente se diagnosticó una tromboembolia de pulmón (TEP). Dada la tórpida evolución y al evidenciarse disnea con desaturación que se acentuaba al sentarse, se realizó un ecocardiograma transesofágico (ETE) que mostró un FOP con aneurisma del septum interauricular y pasaje marcado de burbujas de derecha a izquierda en forma espontánea (en decúbito dorsal). Luego de completar tratamiento antibiótico, se procedió al cierre percutáneo del FOP con la colocación de un Amplatzer.


A patent foramen ovale (PFO) is an atrial septal defect with or without atrial septal aneurysm, associated with left-to-right shunt.It is also related with embolic stroke and platypnea-orthodeoxia syndrome.This report describes the case of a patient with platypnea-orthodeoxia syndrome, which represented a diagnostic challenge because she was admitted due to pneumonia but then was incidentally diagnosed with pulmonary thromboembolism (PTE). Given the unfavorable progression of her condition, and worsening of dyspnea with hypoxemia upon sitting, a transesophageal echocardiography (TEE) was performed, revealing a PFO with atrial septal aneurysm and marked right-to-left bubble passage occurring spontaneously (in dorsal recumbent position). After completion of antibiotic treatment, percutaneous closure of patent foramen ovale was performed with an Amplatzer device.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA