Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Acta cir. bras ; 25(4): 337-341, July-Aug. 2010. ilus
Artigo em Inglês | LILACS | ID: lil-553240

RESUMO

PURPOSE: To verify if the composit poli (2-hydroxyethyl methacrylate)-PolyHEMA/polypropylene mesh implanted in the female rat's abdominal wall could be suitable for the prevention of peritoneal adhesions, and for the evaluation of the tecidual response produced by this biomaterial. METHODS: Polypropylene meshes (Group PP, n=20) and polypropylene meshes coated with a layer of poli (2-hydroxyethyl methacrylate)-PolyHEMA (Group PH, n=20) were implanted on the abdominal wall of Wistar female rats. Ten animals from each group were submitted to euthanasia at 15 and 30 days of the postoperative period. RESULTS: The animals from the group PP presented visceral adhesions on the mesh surface, which was not observed in the ones from group PH. At the histopathological examination foreign body response was observed in both groups, whilst there was a greater intensity of inflammatory response in group PH on both moments. CONCLUSION: The poli (2-hydroxyethyl methacrylate) polyHEMA hydrogel associated to polypropylene mesh reduces visceral adhesion formation in rats, although it may be associated to greater inflammatory reaction.


OBJETIVO: Verificar se compósito poli 2-hidroxietil dimetacrilato (PoliHEMA) / tela de polipropileno implantado na parede abdominal de ratas seria adequado para prevenção de aderências peritoneais e avaliar a resposta tecidual desencadeada por este biomaterial. MÉTODOS: Foram implantadas telas de polipropileno - Grupo PP (n=20) e telas de polipropileno revestidas por uma camada de poli 2 (hidroxietil dimetacrilato)-PolyHEMA - Grupo PH (n=20) na parede abdominal de ratas da linhagem Wistar. Dez animais de cada grupo foram submetidos à eutanásia aos 15 e 30 dias de pós-operatório. RESULTADOS: Os animais do grupo PP apresentaram aderências viscerais na superfície da tela, o que não foi observado nos do grupo PH. Observou-se no exame histopatológico resposta tipo corpo estranho nos dois grupos sendo que no grupo PH houve maior intensidade de resposta inflamatória nos dois momentos. CONCLUSÃO: O hidrogel de poliHEMA quando associado à tela de polipropileno reduz a formação de aderências viscerais em ratos, embora possa estar associado à reação inflamatória mais intensa.


Assuntos
Animais , Feminino , Ratos , Parede Abdominal/cirurgia , Implantes Experimentais , Doenças Peritoneais/prevenção & controle , Peritônio/efeitos dos fármacos , Polipropilenos/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Parede Abdominal/patologia , Materiais Biocompatíveis , Reação a Corpo Estranho/etiologia , Reação a Corpo Estranho/patologia , Inflamação/patologia , Doenças Peritoneais/etiologia , Peritônio/patologia , Poli-Hidroxietil Metacrilato/efeitos adversos , Ratos Wistar , Técnicas de Sutura , Aderências Teciduais/patologia , Aderências Teciduais/prevenção & controle
2.
Acta cir. bras ; 24(2): 144-149, Mar.-Apr. 2009. ilus, tab
Artigo em Inglês | LILACS | ID: lil-511329

RESUMO

PURPOSE: To evaluate and describe immediate effects of the infusion of saline solution heated by SAF® in bitches submitted to halothane anesthesia. METHODS: Thirteen bitches were employed and submitted to elective ovariohysterectomy in acclimatized operating room at 22ºC, allocated in two groups: GI, which received non-heated fluid and GII, which received fluid heated at 37ºC by SAF®. The following parameters were evaluated in 30-minutes intervals (M0, M30, M60 and M90): rectal and cutaneous temperatures (TR and TC), cardiac and respiratory frequencies (HR and ƒ), mean arterial blood pressure (MAP), serum concentration of urea, creatinin, serum activities of alanin aminotranspherasis (ALT), alkaline phosphatasis (ALP) and also hypnosis parameters. RESULTS: There were no significant alterations on clinical and biochemical, but there was group effect on mean arterial blood pressure, urea, ALT, ALP and hypnosis parameters. CONCLUSION: The isolated use of Fluid Heating System (SAF®) was not enough to avoid hypothermia or lead to significant clinical and biochemical alterations in bitches submitted to halothane anesthesia.


OBJETIVO: Avaliar e descrever os efeitos imediatos da infusão de solução salina 0,9 por cento aquecida pelo SAF® sobre cadelas sob anestesia inalatória. MÉTODOS: Foram utilizadas 13 cadelas submetidas a ovariohisterectomia eletiva em centro cirúrgico climatizado a 22ºC, divididas em dois grupos: GI, que recebeu fluido em temperatura ambiente e GII, que recebeu fluido aquecido a 37ºC pelo SAF®. Os parâmetros clínicos avaliados em intervalos de 30 minutos (M0, M30, M60 e M90) foram: temperatura retal (TR) e cutânea (TC), freqüências cardíaca (FR) e respiratória (ƒ), pressão arterial média (PAM), tempo de hipnose, concentrações séricas de uréia e creatinina e atividades das enzimas séricas alanina aminotransferase (ALT) e fosfatase alcalina (ALP). RESULTADOS: Não foram evidenciadas alterações clínicas e bioquímicas significativas, mas houve efeito de grupo sobre as variáveis PAM, uréia, ALT, ALP e tempo de hipnose. CONCLUSÃO: O uso isolado do Sistema de Aquecimento de Fluidos (SAF®) não foi suficiente para evitar o estabelecimento da hipotermia em cadelas submetidas a anestesia geral inalatória, ou promover alterações clínicas e bioquímicas significativas.


Assuntos
Animais , Cães , Feminino , Anestésicos Inalatórios/administração & dosagem , Temperatura Corporal , Hidratação/métodos , Calefação/métodos , Hipotermia/prevenção & controle , Análise de Variância , Hipotermia/fisiopatologia , Estatísticas não Paramétricas
3.
Acta cir. bras ; 22(1): 8-11, Jan.-Feb. 2007. ilus
Artigo em Inglês | LILACS | ID: lil-440725

RESUMO

PURPOSE: To verify whether pediculated diaphragmatic flaps were suitable to correct iatrogenic wounds in dog's esophagus injuries. METHODS: Seven dogs were submitted to resection of a segment of the esophagical wall, which was then corrected by suturing a pediculated diaphragm flap. Endoscopic evaluation of the esophagical wall was done forty days after the surgical procedure. RESULTS: Three animals died, one due to implant ischemia, caused by strangulation of the phrenic artery; other due to wound infection; and the last, due to mediastinitis. Scar retraction was observed, however, there was no stenosis, allowing the passage of a 9,8 mm probe with no difficulty. The limits between the implants and the native esophagus were indistinguishable, and the implant was covered by esophageal mucosa. CONCLUSION: The diaphragmatic flaps are suitable on the restoring of continuity in dog's thoracic esophagus.


OBJETIVO: Verificar se retalhos diafragmáticos pediculados seriam adequados para correção de defeitos iatrogênicos do esôfago do cão. MÉTODOS: Sete cães foram submetidos à ressecção de um segmento da parede esofágica, o qual foi corrigido por meio da sutura de um pedículo diafragmático pediculado. Um animal morreu devido à isquemia do implante causada pelo estrangulamento da artéria frênica, outro devido à infecção da ferida cutânea e outro devido a mediastinite. Aos 40 dias após o procedimento fez-se um exame endoscópico dos animais nos cães sobreviventes. RESULTADOS: Observou-se retração cicatricial sem repercutir em estenose, permitindo a passagem de sonda de 9,8 mm, sem dificuldade. Os limites entre os implantes e o esôfago nativo se apresentaram indistinguíveis e o implante estava recoberto por mucosa esofágica. CONCLUSÃO: Os retalhos diafragmáticos são adequados na restauração da continuidade do esôfago torácico do cão.


Assuntos
Animais , Cães , Diafragma/transplante , Esofagoplastia/veterinária , Retalhos Cirúrgicos/veterinária , Endoscopia , Estenose Esofágica/diagnóstico , Estenose Esofágica/veterinária , Esofagoplastia/efeitos adversos , Cicatrização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA