Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Braz. oral res. (Online) ; 36: e081, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1394172

RESUMO

Abstract This longitudinal study aimed to assess the performance of the Facility-Equator system as mandibular overdenture (MO) retainers from a prosthetic perspective during 2 years of loading and to investigate the oral health-related quality of life (OHRQoL) and whether prosthetic events can affect the OHRQoL. Twenty-four patients (68.1 ± 7.51 years) reported their OHRQoL through the Geriatric Oral Health Assessment Index (GOHAI) and Oral Health Impact Profile (OHIP-EDENT) questionnaires before MO loading and after 1 and 2 years of usage. Prosthetic occurrences were recorded during this period. Data were analyzed using the Wilcoxon test, Mann-Whitney test, and Spearman correlation coefficients. Of the 127 prosthetic events that occurred in the first year, the most frequent events were prosthesis adjustments (16.5%), dislodgement of the Equator attachment (14.17%), and O-ring replacement (11.8%). Eighty-seven prosthetic events were recorded in the second year, the most frequent events being prosthesis adjustments (27.6%), O-ring replacement (20.7%), and recapturing the female matrix (11.5%). All domains of the GOHAI and OHIP-EDENT questionnaires exhibited a significant difference (p < 0.05) between the baseline and 1- and 2-year evaluations, except in the Social Disability and Psychological Discomfort domains (p > 0.05) of OHIP-EDENT after 1 year. Complications related to prosthetic maintenance, such as fracturing of the prosthesis, Equator dislodgement, prosthesis rebasing, and new overdenture confection, affect the OHRQoL (p < 0.05), primarily the Physical Pain and Discomfort domains, especially in the first year of MO loading.

2.
Braz. dent. j ; 31(4): 399-403, July-Aug. 2020. tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1132316

RESUMO

Abstract: This cross-sectional observational study with 24 patients evaluated differences in bite force (BF) and masticatory performance (MP) between conventional complete denture (CCD) and implant mandibular overdenture (IMO) users and the correlation between these variables. The BF test was performed bilaterally with an occlusal force device. During the MP test, patients were asked to chew Optocal particles for 40 cycles. The Shapiro Wilk test was employed to verify the normality of the data, the student t test to identify differences between groups, and Pearson's correlation to investigate interrelationships between variables. A multiple linear regression was subsequently performed via the stepwise method. P values ≤0.05 were considered statistically significant. Unlike IMO users, CCD users presented a significant difference (25.6%) in BF between the dominant and non-dominant chewing side (p=0.04). IMO users presented significantly higher BF (p=0.01) without presenting a dominant side (p=0.38), and also performed significantly better for the following MP parameters: MPX50 values decreased by 27.25% in IMO users (p=0.01), MPB decreased by 48.38% (p=0.01), and ME 5.6 decreased by 53.25% (p=0.02), while ME2.8 increased by 151.57% (p=0.01). The BF and MPX50 in the IMO wearers group were negatively correlated (-0.57; p=0.05); this correlation coefficient was the only parameter included in the multivariate regression model. IMO users have higher BF and better masticatory performance than CCD users, especially in terms of chewed particles size reduction. MP is correlated with a higher BF in IMO users through better particle trituration.


Resumo Este estudo observacional transversal com 24 participantes teve como objetivo avaliar as diferenças na força de mordida (FM) e na PM (performance mastigatória) entre usuários de prótese total convencional (PTC) e de overdenture mandibular (OM) e a correlação entre essas variáveis. O teste de FM foi realizado bilateralmente com um dispositivo de força oclusal. Durante o teste de PM, os pacientes foram solicitados a mastigar uma porção padronizada de Optocal por 40 ciclos mastigatórios. O teste de Shapiro Wilk foi empregado para verificar a normalidade dos dados, o teste T de Student para identificar diferenças entre os grupos e os coeficientes de correlação de Pearson para investigar inter-relações entre variáveis. Uma regressão linear múltipla foi realizada pelo método stepwise. Valores de p≤0,05 foram considerados estatisticamente significantes. Diferentemente dos usuários de OM, os usuários de PTC apresentaram uma diferença significativa (34%) na FM entre o lado dominante e o não dominante (p=0,04). Os usuários de OM apresentaram FM significativamente maior (p=0,01) sem apresentar um lado dominante (p=0,38) e obtiveram PM significativamente melhor nos seguintes parâmetros: os valores de PMX50 diminuíram 27,25% (p=0,01), PMB diminuiu em 48,38% (p=0,01), e EM 5.6 diminuiu 53,25% (p=0,02), enquanto EM2.8 aumentou 151,57% (p=0,01). A FM e PMX50 no grupo de usuários da IMO foram negativamente correlacionados (-0,57;p=0,05); esse coeficiente de correlação foi o único parâmetro incluído no modelo de regressão multivariada. Os usuários da OM possuem maior FM e melhor performance mastigatória do que os usuários de PTC, observados principalmente na redução do tamanho das partículas mastigadas. A PM está correlacionada com um maior FM nos usuários da OM através de uma melhor trituração de partículas.


Assuntos
Humanos , Força de Mordida , Revestimento de Dentadura , Estudos Transversais , Prótese Total , Mandíbula
3.
Braz. j. oral sci ; 17: e18371, 2018. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-963971

RESUMO

Aim: This study characterized the implant surfaces available on the Brazilian market in terms of topography, chemical composition, and roughness. Methods: The following brands were selected according to their surfaces: Kopp (Ko), Signo Vinces (Sv), Neodent (Ne), Osseotite (Os) NanoTite (Nt), SIN (Si), Titanium Fix (Tf), conventional Straumann (Str), Active SLA (SLA). The morphological analysis and the alloy impurities and implant surface contaminants were analyzed by SEM-EDS. Surface roughness parameters and 3-D reconstructions were obtained by laser microscopy (20x). Two distinct areas were evaluated: i) the cervical portion (no surface treatment), and ii) the middle third (treated surface). Results: The characterization of the implant surfaces by SEM showed morphological differences between the thread geometries and surface morphology at 800x and 2000x magnification. The EDS elemental analysis showed a predominance of titanium (Ti) for all implants. The SLA surface showed only peaks of Ti while other implants brands showed traces of impurities and contaminants including Al, C, PR, F, Mg, Na, Ni, O, P, and SR. The implant surface roughness in the cervical portion did not exceed Ra 0.5­1.0 µm, constituting a minimally rough surface and obtaining acceptable standards for this region. Only Nt, Str, and SLA presented Ra above 2 µm in the middle third area showing a rough surface favorable for osseointegration. Conclusion: This study concluded that there is no established standard for morphology, chemical composition and implant surface roughness that allows a safe comparison between the available dental implant surfaces. National implant brands generally contain more impurities and surface contaminants than their international counterparts and were consequently more sensitive to the surface treatment techniques


Assuntos
Espectrometria por Raios X , Propriedades de Superfície , Implantes Dentários
4.
Braz. oral res. (Online) ; 31: e5, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839513

RESUMO

Abstract The aim of this longitudinal observational study was to evaluate the oral health-related quality of life (OHRQoL) following patient rehabilitation with implant-retained mandibular overdentures (IMO) and to identify the contribution of the different domains to OHRQoL. The Oral Health Impact Profile (OHIP-EDENT), Dental Impact on Daily Living (DIDL), and Geriatric Oral Health Assessment Index (GOHAI) questionnaires were completed twice by 25 patients: after 3 months of rehabilitation with complete dentures (CD) and after 3 months of IMO loading using stud abutments. The evaluation after IMO rehabilitation showed significant improvement in three DIDL domains: appearance (p = 0.011), eating and chewing (p = 0.003), and general performance (p = 0.003). The GOHAI results showed significant differences in two domains: psychosocial (p = 0.005) and pain and discomfort (p = 0.0004). The OHIP-EDENT outcomes showed significant improvements in five domains: functional limitation (p = 0.0001), physical pain (p = 0.0002), physical disability (p = 0.0010), and psychological disability and handicap (p = 0.032). The largest observed effect sizes were close to one standard deviation and were observed in the eating and chewing domain (0.93) of the DIDL; the pain and discomfort domain (0.83) of the GOHAI, and the functional limitation (0.89), physical pain (1.02), physical disability (0.84) domains of the OHIP-EDENT. The percentage of satisfied patients increased in all domains. Self-reported OHRQoL of CD wearers was significantly improved after 3 months of treatment with IMO, especially concerning the functional and pain-related aspects.


Assuntos
Humanos , Masculino , Feminino , Idoso , Qualidade de Vida , Implantes Dentários , Saúde Bucal , Prótese Mandibular , Autoimagem , Dor Facial/fisiopatologia , Atividades Cotidianas , Estudos Longitudinais , Satisfação do Paciente , Estatísticas não Paramétricas , Revestimento de Dentadura , Revestimento de Dentadura/psicologia , Avaliação da Deficiência , Autorrelato , Prótese Mandibular/psicologia
5.
Braz. dent. j ; 26(4): 390-392, July-Aug. 2015. tab
Artigo em Inglês | LILACS | ID: lil-756379

RESUMO

This study evaluated the tension force of cast frameworks made by the technique of framework cemented on prepared abutments using two different resin cements. Forty multi-unit abutment analogs were individually fixed with chemically cured acrylic resin inside PVC cylinders using a parallelometer. Brass cylindrical abutments were tightened to the multi-unit abutments to be used as spacers and then castable UCLA abutments were positioned above. These abutments were cast with Ni-Cr and then divided into 4 groups (n=10): cemented with RelyX U100(r); cemented with RelyX U100(r) and simulation of acrylic resin polymerization process; cemented with Multilink(r); and cemented with Multilink(r) and simulation of acrylic resin polymerization process. Abutments were cemented according to manufacturers' instructions. In a universal testing machine, tensile strength was applied in the direction of the long axis of the abutments at 1 mm/min crosshead speed until displacement of the luted abutments was obtained. The values of maximum tensile force (N) required for the displacement of the luted abutments were tabulated and analyzed statistically by one-way ANOVA with a 95% confidence level. No statistically significant difference was found among the groups (p>0.05). There was an increase in mean tension force when the specimens were subjected to the simulation of acrylic resin polymerization process, but the results did not differ statistically. Both resin cements presented positive results as regards the retention of luted abutments on their respective multi-unit abutments. Both materials may be indicated for the technique of framework cemented on prepared abutments when professionals pursuit better adaptation of implant-supported frameworks.

.

Este estudo avaliou a força de tração de infraestruturas fundidas confeccionadas pela técnica da infraestrutura cimentada sobre pilares preparados utilizando dois diferentes cimentos resinosos. Quarenta análogos de pilares multi-unit foram individualmente fixados com resina acrílica quimicamente ativada em cilindros de PVC utilizando um delineador. Pilares cilíndricos foram torqueados aos pilares multi-unit para serem usados como espaçadores e, então, pilares calcináveis UCLA foram posicionados sobre eles. Estes pilares foram fundidos em liga de Ni-Cr e divididos em 4 grupos (n=10): cimentados com RelyX U100(r); cimentados com RelyX U100(r) e simulação do processo de polimerização da resina acrílica; cimentados com Multilink(r); e cimentados com Multilink(r) e simulação do processo de polimerização da resina acrílica. Os pilares foram cimentados de acordo com as recomendações dos fabricantes. Em máquina universal de ensaio, a resistência à tração foi aplicada na direção do longo eixo dos pilares a uma velocidade de 1 mm/min até o deslocamento do pilar cimentado ser obtido. Os valores da tração máxima (N) necessária para o deslocamento dos pilares cimentados foram tabulados e analisados estatisticamente pela ANOVA de 1 fator com 95% de nível de confiança. Diferença estatisticamente significativa não foi encontrada entre os grupos (p>0,05). Houve um aumento na força média de tração quando os espécimes foram submetidos à simulação de processo de polimerização da resina acrílica, mas os resultados não diferiram estatisticamente. Ambos os cimentos resinosos apresentaram resultados positivos no que diz respeito à retenção dos pilares cimentados em seus respectivos pilares multi-unit. Ambos os materiais podem ser indicados para a técnica da infraestrutura cimentada sobre pilares preparados quando os profissionais buscam melhor adaptação de infraestruturas de próteses implanto-suportadas.

.


Assuntos
Dente Suporte , Cimentos de Resina , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA