Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Medical Instrumentation ; (6): 84-87, 2014.
Artigo em Chinês | WPRIM | ID: wpr-259926

RESUMO

In order to meet the requirements of the multi-physiological signal measurement of the 3D-TV health assessment, try to find the suitable biological acquisition chips and design the hardware system which can detect different physiological signals in real time. The systems mainly uses ARM11/S3C6410 microcontroller to control the EEG/EOG acquisition chip RHA2116 and the ECG acquisition chip ADS1298, and then the microcontroller transfer the data collected by the chips to the PC software by the USB port which can display and save the experimental data in real time, then use the Matlab software for further processing of the data, finally make a final health assessment. In the meantime, for the different varieties in the different brain regions of watching 3D-TV, developed the special brain electrode placement and the experimental data processing methods, then effectively disposed the multi-signal data in the multilevel.


Assuntos
Simulação por Computador , Desenho de Equipamento , Microcomputadores , Fenômenos Fisiológicos , Processamento de Sinais Assistido por Computador , Software
2.
Journal of Biomedical Engineering ; (6): 402-407, 2002.
Artigo em Chinês | WPRIM | ID: wpr-357016

RESUMO

The parallel-plate flow chamber (PPFC) with rectangular shape, of which the height is far smaller than its own length and width, is one of the main apparatus for in vitro studies of the mechanical behavior of the cells. Considering that the Reynolds numbers of flows in the usually used PPFCs are small, a perturbation solution of laminar pulsatile Casson fluid in the PPFC is presented using Reynolds number as perturbation parameter. Furthermore, the velocities and shear stresses in the PPFC are given. The numerical results demonstrate that under the same pressure gradient the shear stresses are almost identical between Casson fluid and Newtonian fluid, whereas under the same flux the shear stresses are obviously different between Casson fluid and Newtonian fluid. The results in this paper provide a theoretical way to determine the shear stresses in the parallel-plate flow chamber under pulsatile Casson fluid.


Assuntos
Algoritmos , Técnicas In Vitro , Modelos Cardiovasculares , Fluxo Pulsátil , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS