Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Colomb. med ; 54(1)mar. 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1534276

RESUMO

Background: Older adults admitted to a hospital for acute illness are at higher risk of hospital-associated functional decline during stays and after discharge. Objective: This study aimed to assess the calibration and discriminative abilities of the Hospital Admission Risk Profile (HARP) and the Identification of Seniors at Risk (ISAR) scales as predictors of hospital-associated functional decline at discharge in a cohort of patients older than age 65 receiving management in an acute geriatric care unit in Colombia. Methods: This study is an external validation of ISAR and HARP prediction models in a cohort of patients over 65 years managed in an acute geriatric care unit. The study included patients with Barthel index measured at admission and discharge. The evaluation discriminate ability and calibration, two fundamental aspects of the scales. Results: Of 833 patients evaluated, 363 (43.6%) presented hospital-associated functional decline at discharge. The HARP underestimated the risk of hospital-associated functional decline for patients in low- and intermediate-risk categories (relation between observed/expected events (ROE) 1.82 and 1.51, respectively). The HARP overestimated the risk of hospital-associated functional decline for patients in the high-risk category (ROE 0.91). The ISAR underestimated the risk of hospital-associated functional decline for patients in low- and high-risk categories (ROE 1.59 and 1.11). Both scales showed poor discriminative ability, with an area under the curve (AUC) between 0.55 and 0.60. Conclusions: This study found that HARP and ISAR scales have limited discriminative ability to predict HAFD at discharge. The HARP and ISAR scales should be used cautiously in the Colombian population since they underestimate the risk of hospital-associated functional decline and have low discriminative ability.


Antecedentes: los adultos mayores ingresados en un hospital por una enfermedad aguda tienen un mayor riesgo de deterioro functional hospitalario durante su estancia y después del alta. Objetivo: este estudio tuvo como objetivo evaluar las capacidades de calibración y discriminación de las escalas Hospital Admission Risk Profile (HARP) e Identification of Seniors at Risk (ISAR) como predictores de deterioro funcional hospitalario al alta en una cohorte de pacientes mayores de 65 años que recibieron manejo en una unidad geriátrica de agudos en Colombia. Métodos: este estudio es una validación externa de los modelos de predicción ISAR y HARP en una cohorte de pacientes mayores de 65 años atendidos en una unidad geriátrica de agudos. El estudio incluyó pacientes con índice de Barthel medido al ingreso y al alta y la evaluación de la capacidad de discriminación y calibración, dos aspectos fundamentales para esta medición. Resultados: de 833 pacientes evaluados, 363 (43.6%) presentaron deterioro funcional hospitalario al momento del alta. La escala HARP subestimó el riesgo de deterioro funcional hospitalario para los pacientes en las categorías de riesgo bajo e intermedio (relación entre eventos observados /esperados (ROE) 1.82 y 1.51, respectivamente). El HARP sobrestimó el riesgo de deterioro funcional hospitalario para pacientes en la categoría de alto riesgo (ROE 0.91). El ISAR subestimó el riesgo de deterioro hospitalario para pacientes en categorías de bajo y alto riesgo (ROE 1.59 y 1.11). Ambas escalas mostraron una pobre capacidad de discriminación, con un área bajo la curva (AUC) entre 0.55 y 0.60. Conclusiones: este estudio encontró que las escalas HARP e ISAR tienen una capacidad de discriminación limitada para predecir deterioro funcional hospitalario al alta. Las escalas HARP e ISAR deben usarse con cautela en la población colombiana ya que subestiman el riesgo de deterioro funcional hospitalario y tienen baja capacidad de discriminación.

2.
Braz. j. vet. res. anim. sci ; 47(1): 5-12, 2010. ilus
Artigo em Português | LILACS | ID: lil-557556

RESUMO

Devido à necessidade de compreender melhor as interações entre leptina e reprodução, um ria específico para a leptina bovina foi validado. Primeiro, um protocolo para produção de anticorpos foi desenvolvido por meio da inoculação de leptina recombinante equina em um coelho, que resultou em 28,05% de ligação máxima (MB) 105 dias após o inicio do protocolo. Os testes de validação verificaram paralelismo entre a curva padrão e as diluições dos controles alto e baixo (p<0,01). O anticorpo contra leptina equina mostrou especificidade para a leptina bovina (p<0,01). A taxa de recuperação da leptina bovina pelo anticorpo contra leptina recombinante equina foi de 98,4 a 101,6% (p < 0, 01). Quando as amostras foram armazenadas em temperatura ambiente ou refrigeradas à 4°c, foi verificado estabilidade de ligação (p > 0,2), no entanto temperaturas acima de 37°C interferiram negativamente na recuperação da leptina bovina. O uso do tampão de ensaio com ou sem a adição de plasma não apresentou diferenças (p > 0,3). Esses resultados demonstraram que o anticorpo produzido em coelho contra leptina equina foi capaz de detectar a leptina plasmática bovina, e que o ria para a quantificação da leptina bovina apresentou características adequadas para o desenvolvimento de um ensaio válido.


Due necessity of better understanding leptin and reproduction relations, a specific radioimmunoassay (RIA) to bovine leptin was validated. First, an antibody production protocol was developed using recombinant equine leptin inoculated in a rabbit, that results in 28,05% of maximum binding (MB) 105 days after the protocol beginning. The tests of validations verified parallelism between standard curve and dilutions of high and low controls (P < 0,01). Antibody against equine leptin showed specificity to bovine leptin (P < 0,01). The recuperation tax of bovine leptin by antibody against recombinant equine leptin was from 98,4 to 101,6% (P < 0, 01). When the samples were stored in ambient temperature or refrigerated to 4°C, ligation stability was verified (P > 0,2), howether, temperatures above 37°C impaired the bovine leptin recuperation. The use of assay buffer with or without bovine plasma did not show difference (P > 0,3). These results showed that the antibody produced in rabbit against equine leptin were able to detect plasmatic bovine leptin, and that the RIA to bovine leptin quantification had adequate characteristics to the development of a valid assay.


Assuntos
Animais , Bovinos , Inoculações Seriadas/métodos , Inoculações Seriadas/veterinária , Leptina/biossíntese , Leptina/imunologia , Radioimunoensaio/veterinária , Anticorpos , Bovinos
3.
Braz. j. vet. res. anim. sci ; 45(1): 11-16, 2008. graf
Artigo em Português | LILACS | ID: lil-488559

RESUMO

O presente estudo teve como objetivo traçar o perfil de gonadotrofinas em 12 novilhas Nelore, a fim de testar a hipótese de que há declínio nas concentrações de FSH e elevação transitória nos níveis de LH durante a seleção folicular. A partir da ovulação (D0) foram colhidas amostras de sangue da veia jugular a cada 12 horas até o D5, para a dosagem de FSH e LH plasmáticos. Empregou-se o método de radioimunoensaio de duplo anticorpo. A sensibilidade do ensaio de LH foi de 0,02ng/ml e a de FSH de 0,005ng/ml. Os coeficientes de variação intra-ensaio foram 13,6% e 18,8%, respectivamente. Os dados (média±EPM) foram normalizados para o momento da divergência folicular e, posteriormente, analisados por ANOVA e por regressão inear, cúbica e quadrática. Também foi empregado o Teste t para comparação entre o ponto mais alto e o mais baixo da curva. Não se verificou efeito de tempo sobre as concentrações plasmáticas de FSH e de LH quando se utilizou análise de variância e de regressão. Entretanto, através do Teste t pontual, o FSH atingiu as menores concentrações plasmáticas 36 (0,40±0,05ng/ml) e 60 horas (0,42±0,04ng/ml) após a divergência, comparativamente às 36 horas anteriores ao desvio, quando as concentrações foram máximas (0,63±0,08ng/ml). Conclui-se, portanto, que há declínio nas concentrações plasmáticas de FSH, contudo, não foi comprovada elevação transitória nas concentrações de LH próximo ao momento do desvio folicular em fêmeas Nelore.


Present study aimed to evaluate gonadotropins profiles in 12 Nelore heifers, in order to test the hypothesis that FSH concentrations decrease and LH presents a transient increase during follicle selection. Blood samples from jugular vein were harvested twice daily starting at the time of ovulation (D0) until D5. Plasma samples were assayed for FSH and LH by double antibody radioimmunoassay method. LH and FSH assay sensitivity was 0,02ng/ml and 0,005ng/ml, respectively. The intraassay coefficient of variation was 13,6% and 18,8%, respectively. Data (mean±SEM) were normalized to follicle deviation and analyzed by ANOVA and by linear, cubic, and quadratic regressions. Comparisons between higher and lower FSH values were also performed by T-test. There was no effect of time in plasmatic FSH and LH circulating levels when variance analysis or regression analysis were performed. However, by T-test, FSH concentrations reached the lowest plasmatic levels 36 (0,40±0,05ng/ml) and 60 hours (0,42±0,04ng/ml) after follicular deviation, comparatively to 36 hours before deviation, when the concentrations were maximal (0,63±0,08ng/ml). In conclusion, there is a FSH decrease, although a transient LH elevation has not been confirmed encompassing follicle deviation in Nelore females.


Assuntos
Animais , Bovinos , Hormônio Foliculoestimulante , Gonadotropinas/efeitos adversos , Hormônio Luteinizante/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA