Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Rev. bras. anestesiol ; 70(2): 82-89, Mar.-Apr. 2020. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1137154

RESUMO

Abstract Background and objectives: The perioperative cardiac arrest (CA) and mortality rates in Brazil, a developing country, are higher than in developed countries. The hypothesis of this review was that knowledge of the epidemiology of perioperative CA and mortality in Brazil enables the comparison with developed countries. The systematic review aimed to verify, in studies conducted in Brazil, the epidemiology of perioperative CA and mortality. Method and results: A search strategy was carried out on different databases (PubMed, EMBASE, SciELO and LILACS) to identify observational studies that reported perioperative CA and/or mortality up to 48 hours postoperatively in Brazil. The primary outcomes were data on epidemiology of perioperative CA and mortality. In 8 Brazilian studies, there was a higher occurrence of perioperative CA and mortality in males; in extremes of age; in patients in worse physical status according to the American Society of Anesthesiologists (ASA); in emergency surgeries; in general anesthesia; and in cardiac, thoracic, vascular, abdominal and neurological surgeries. The patient's disease/condition was the main triggering factor, with sepsis and trauma as the main causes. Conclusions: The epidemiology of both perioperative CA and mortality events reported in Brazilian studies does not show important differences and, in general, is similar to studies in developed countries. However, sepsis represents one of the major causes of perioperative CA and mortality in Brazilian studies, contrasting with studies in developed countries in which sepsis is a secondary cause.


Resumo Justificativa e objetivos: As incidências de parada cardíaca (PC) e de mortalidade perioperatória no Brasil, um país em desenvolvimento, são mais elevadas em relação às dos países desenvolvidos. A hipótese desta revisão é que o conhecimento da epidemiologia de PC e de mortalidade perioperatória no Brasil possibilita sua comparação com a dos países desenvolvidos. A revisão sistemática teve como objetivo verificar, em estudos realizados no Brasil, a epidemiologia de PC e de mortalidade perioperatória. Conteúdo: Realizou-se estratégia de busca em diferentes bases de dados (PubMed, EMBASE, SciELO e LILACS) para a identificação de estudos observacionais que reportaram PC e/ou mortalidade perioperatória até 48 horas pós-operatório no Brasil. Os desfechos primários foram dados de epidemiologia de PC e de mortalidade perioperatória. Em 8 estudos nacionais, identificou- se maior ocorrência de PC e de mortalidade perioperatória no sexo masculino, em extremos de idade, em pacientes em pior estado físico segundo a American Society of Anesthesiologists (ASA), em cirurgias de emergência, em anestesia geral, e em cirurgias cardíaca, torácica, vascular, abdominal e neurológica. A doença/condição do paciente foi o principal fator desencadeante, tendo como causas principais a sepse e o trauma. Conclusões: Nos estudos nacionais, a epidemiologia dos eventos tanto de PC como de mortalidade perioperatória não apresenta diferenças importantes, e de maneira geral, é semelhante à de estudos de países desenvolvidos. Entretanto, a sepse, nos estudos nacionais, representa uma das principais causas de PC e de mortalidade perioperatória, diferenciando-se dos estudos de países desenvolvidos nos quais a sepse é causa secundária.


Assuntos
Humanos , Complicações Pós-Operatórias/epidemiologia , Parada Cardíaca/epidemiologia , Complicações Pós-Operatórias/mortalidade , Brasil/epidemiologia , Parada Cardíaca/mortalidade
2.
Rev. bras. anestesiol ; 67(5): 516-520, Sept-Oct. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-897762

RESUMO

Abstract Background and objectives Occupational exposure to waste anesthetic gases in operating room without active scavenging system has been associated with adverse health effects. Thus, this study aimed to compare the trace concentrations of the inhalational anesthetics isoflurane and sevoflurane in operating room with and without central scavenging system. Method Waste concentrations of isoflurane and sevoflurane were measured by infrared analyzer at different locations (near the respiratory area of the assistant nurse and anesthesiologist and near the anesthesia station) and at two times (30 and 120 min after the start of surgery) in both operating room types. Results All isoflurane and sevoflurane concentrations in unscavenged operating room were higher than the US recommended limit (2 parts per million), regardless of the location and time evaluated. In scavenged operating room, the average concentrations of isoflurane were within the limit of exposure, except for the measurements near the anesthesia station, regardless of the measurement times. For sevoflurane, concentrations exceeded the limit value at all measurement locations and at both times. Conclusions The exposure to both anesthetics exceeded the international limit in unscavenged operating room. In scavenged operating room, the concentrations of sevoflurane, and to a lesser extent those of isoflurane, exceeded the recommended limit value. Thus, the operating room scavenging system analyzed in the present study decreased the anesthetic concentrations, although not to the internationally recommended values.


Resumo Justificativa e objetivos A exposição ocupacional aos resíduos de gases anestésicos em salas de operação (SO) sem sistema ativo de exaustão tem sido associada a efeitos adversos à saúde. Assim, o objetivo do estudo foi comparar os resíduos dos anestésicos inalatórios isoflurano e sevoflurano em SO com e sem sistema de exaustão. Método Concentrações residuais de isoflurano e sevoflurano foram mensuradas por analisador infravermelho em diferentes locais (próximo à área respiratória do auxiliar de enfermagem e do anestesiologista e próximo à estação de anestesia) e em dois momentos (30 e 120 min após o início da cirurgia) em ambos os tipos de SO. Resultados Todas as concentrações de isoflurano e sevoflurano nas SO sem sistema de exaustão foram mais elevadas em relação ao valor limite recomendado pelos EUA (2 partes por milhão), independentemente do local e momento avaliados. Nas SO com sistema de exaustão, as concentrações médias de isoflurano ficaram dentro do limite de exposição, exceto para as mensurações próximas à estação de anestesia, independentemente dos momentos avaliados. Para o sevoflurano, as concentrações excederam o valor limite em todos locais de medição e nos dois momentos. Conclusões A exposição a ambos os anestésicos excedeu o limite internacional nas SO sem sistema de exaustão. Nas SO com sistema de exaustão, as concentrações de sevoflurano, e em menor extensão, as de isoflurano excederam o valor limite recomendado. Dessa forma, o sistema de exaustão das SO analisado no presente estudo diminuiu as concentrações dos anestésicos, embora não tenha reduzido a valores internacionalmente recomendados.


Assuntos
Depuradores de Gases , Poluição do Ar em Ambientes Fechados/análise , Anestésicos Inalatórios/análise , Sevoflurano/análise , Isoflurano/análise , Salas Cirúrgicas , Brasil , Hospitais Universitários
3.
In. Vieira, Joaquim Edson; Rios, Isabel Cristina; Takaoka, Flávio. Anestesia e bioética / Anesthesia and bioethics. São Paulo, Atheneu, 8; 2017. p.51-61.
Monografia em Português | LILACS | ID: biblio-847825
4.
Acta cir. bras ; 29(4): 280-286, abr. 2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-706959

RESUMO

To investigate the effects of occupational exposure to waste anesthetic gases on genetic material and antioxidant status in professionals during their medical residency. The study group consisted of 15 medical residents from Anesthesiology and Surgery areas, of both genders, mainly exposed to isoflurane and to a lesser degree to sevoflurane and nitrous oxide; the control group consisted of 15 young adults not exposed to anesthetics. Blood samples were drawn from professionals during medical residency (eight, 16 and 22 months of exposure to waste anesthetic gases). DNA damage was evaluated by comet assay, and antioxidant defense was assessed by total thiols and the enzymes glutathione peroxidase (GPX), superoxide dismutase (SOD) and catalase (CAT). When comparing the two groups, DNA damage was significantly increased at all time points evaluated in the exposed group; plasma thiols increased at 22 months of exposure and GPX was higher at 16 and 22 months of exposure. Young professionals exposed to waste anesthetic gases in operating rooms without adequate scavenging system have increased DNA damage and changes in redox status during medical residency. There is a need to minimize exposure to inhalation anesthetics and to provide better work conditions.


Assuntos
Animais , Ratos , Anestesiologia/métodos , Antioxidantes/farmacologia , Avaliação de Danos , DNA , Gases/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA