Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
Korean Journal of Hepato-Biliary-Pancreatic Surgery ; : 184-188, 2009.
Artigo em Coreano | WPRIM | ID: wpr-193886

RESUMO

Adrenocortical oncocytoma is a very rare disease which has been reported in 40 cases. A 27-years-old female patient was admitted for a suspicious hepatocellular mass on ultrasonogram. On CT scan, sono-guided needle biopsy and 18F-FDG PET scan, all results were unsatisfactory. During laparotomy, the mass was originated from Rt. adrenal gland and liver was pushed sideward by the mass. On pathology report, an adrenocortical oncocytoma was diagnosed. Adrenocortical oncocytoma has pathological characteristics comprised of oncocytes with granular, eosinophilic cytoplasm, and sufficient mitochondria in their cytoplasm. There were no established criteria for differential diagnose between benign and malignant adrenocortical oncocytoma. There are no sufficient data for the long-term outcome of adrenocortical oncocytoma in the medical literature. Thus we report a case of adrenocortical oncocytoma with review of the related literature.


Assuntos
Feminino , Humanos , Adenoma Oxífilo , Glândulas Suprarrenais , Biópsia por Agulha , Carcinoma Hepatocelular , Citoplasma , Eosinófilos , Fluordesoxiglucose F18 , Laparotomia , Fígado , Mitocôndrias , Células Oxífilas , Tomografia por Emissão de Pósitrons , Doenças Raras
2.
Journal of Korean Academy of Conservative Dentistry ; : 130-136, 2009.
Artigo em Coreano | WPRIM | ID: wpr-40936

RESUMO

The aim of this study was to develop a method for measuring the slumping resistance of flowable resin composites and to evaluate the efficacy using rheological methodology. Five commercial flowable composites (Aelitefil flow:AF, Filtek flow:FF, DenFil flow:DF, Tetric flow:TF and Revolution:RV) were used. Same volume of composites in a syringe was extruded on a glass slide using a custom-made loading device. The resin composites were allowed to slump for 10 seconds at 25degrees C and light cured. The aspect ratio (height/diameter) of cone or dome shaped specimen was measured for estimating the slumping tendency of composites. The complex viscosity of each composite was measured by a dynamic oscillatory shear test as a function of angular frequency using a rheometer. To compare the slumping tendency of composites, one way-ANOVA and Turkey's post hoc test was performed for the aspect ratio at 95% confidence level. Regression analysis was performed to investigate the relationship between the complex viscosity and the aspect ratio. The results were as follows. 1. Slumping tendency based on the aspect ratio varied among the five materials (AF < FF < DF < TF < RV). 2. Flowable composites exhibited pseudoplasticity in which the complex viscosity decreased with increasing frequency (shear rate). AF was the most significant, RV the least. 3. The slumping tendency was strongly related with the complex viscosity. Slumping resistance increased with increasing the complex viscosity. The slumping tendency could be quantified by measuring the aspect ratio of slumped flowable composites. This method may be applicable to evaluate the clinical handling characteristics of flowable composites.


Assuntos
Resinas Compostas , Vidro , Manobra Psicológica , Luz , Seringas , Viscosidade
3.
Journal of Korean Academy of Conservative Dentistry ; : 141-147, 2008.
Artigo em Coreano | WPRIM | ID: wpr-105057

RESUMO

This study was aimed to develop an instrument for real-time measurement of fluid conductance and to investigate the hydrodynamics of dentinal fluid. The instrument consisted of three parts; (1) a glass capillary and a photo sensor for detection of fluid movement, (2) a servo-motor, a lead screw and a ball nut for tracking of fluid movement, (3) a rotary encoder and software for data processing. To observe the blocking effect of dentinal fluid movement, oxalate gel and self-etch adhesive agent were used. BisBlock (Bisco) and Clearfil SE Bond (Kuraray) were applied to the occlusal dentin surface of extracted human teeth. Using this new device, the fluid movement was measured and compared between before and after each agent was applied. The instrument was able to measure dentinal fluid movement with a high resolution (0.196 nL) and the flow occurred with a rate of 0.84 to 15.2 nL/s before treatment. After BisBlock or Clearfil SE Bond was used, the fluid movement was decreased by 39.8 to 89.6%.


Assuntos
Humanos , Adesivos , Capilares , Dentina , Sensibilidade da Dentina , Líquido Dentinal , Vidro , Hidrodinâmica , Nozes , Ácido Oxálico , Cimentos de Resina , Dente , Atletismo
4.
Journal of Korean Academy of Conservative Dentistry ; : 489-497, 2004.
Artigo em Coreano | WPRIM | ID: wpr-194029

RESUMO

OBJECTIVE: The purpose of this study was to investigate the viscoelastic properties related to handling characteristics of composite resins. METHODS: A custom designed vertical oscillation rheometer (VOR) was used for rheological measurements of composites. The VOR consists of three parts: (1) a measuring unit, (2) a deformation induction unit and (3) a force detecting unit. Two medium viscous composites, Z100 and Z250 and two packable composites, P60 and SureFil were tested. The viscoelastic material function, including complex modulus E* and phase angle delta, were measured. A dynamic oscillatory test was used to evaluate the storage modulus (E'), loss modulus (E") and loss tangent (tandelta) of the composites as a function of frequency (omega) from 0.1 to 20 Hz at 23degrees C. RESULTS: The E' and E" increased with increasing frequency and showed differences in magnitude between brands. The E*s of composites at omega = 2 Hz, normalized to that of Z100, were 2.16 (Z250), 4.80 (P60) and 25.21 (SureFil). The magnitudes and patterns of the change of tandelta of composites with increasing frequency were significantly different between brands. The relationships between the complex modulus E*, the phase angle delta and the frequency omega were represented by frequency domain phasor form, E* (omega) = E*e(idelta) = E* 45 degree angle delta. CONCLUSIONS: The viscoelasticity of composites that influences handling characteristics is significant different between brands. The VOR is a relatively simple device for dynamic, mechanical analysis of high viscous dental composites. The locus of frequency domain phasor plots in a complex plane is a valuable method of representing the viscoelastic properties of composites.


Assuntos
Resinas Compostas
5.
Journal of Korean Academy of Conservative Dentistry ; : 520-531, 2004.
Artigo em Coreano | WPRIM | ID: wpr-194025

RESUMO

OBJECTIVES: The aim of this study was to investigate the effect of monomer and filler compositions on the rheological properties related to the handling characteristics of resin composites. METHODS: Resin matrices that Bis-GMA as base monomer was blended with TEGDMA as diluent at various ratio were mixed with the Barium glass (0.7 um and 1.0 um), 0.04 um fumed silica and 0.5 um round silica. All used fillers were silane treated. In order to vary the viscosity of experimental composites, the type and content of incorporated fillers were changed. Using a rheometer, a steady shear test and a dynamic oscillatory shear test were used to evaluate the viscosity (eta) of resin matrix, and the storage shear modulus (G'), the loss shear modulus (G"), the loss tangent (tandelta) and the complex viscosity (eta*) of the composites as a function of frequency omega = 0.1-100 rad/s. To investigate the effect of temperature on the viscosity of composites, a temperature sweep test was also undertaken. RESULTS: Resin matrices were Newtonian fluid regardless of diluent concentration and all experimental composites exhibited pseudoplastic behavior with increasing shear rate. The viscosity of composites was exponentially increased with increasing filler volume%. In the same filler volume, the smaller the fillers were used, the higher the viscosities were. The effect of filler size on the viscosity was increased with increasing filler content. Increasing filler content reduced tandelta by increasing the G' further than the G". The viscosity of composites was decreased exponentially with increasing temperature.


Assuntos
Bário , Bis-Fenol A-Glicidil Metacrilato , Vidro , Reologia , Dióxido de Silício , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA