Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Acta ortop. bras ; 30(5): e254358, 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403050

RESUMO

ABSTRACT Joint stiffness is the most common complication in elbow injuries, presenting several etiologies and pathophysiological mechanisms that hinder treatment and prognosis. Prevention and treatment of joint contracture depend on the cause of stiffness, and early intervention should modify its outcomes. The methods used may be conservative or surgical, alone or in combination, according to each individual situation. Objective: Review articles on articulated elbow orthosis for joint stiffness rehabilitation. Methods: A literature review was conducted in journals available at the PubMed, Medline and LILACS databases, using the following Health Science Descriptors (DeCS): orthotic devices; braces; elbow; elbow joint; contracture; joint disorders. It sought to retrieve and analyze studies with the highest level of evidence that have already been conducted on articulated elbow orthosis for joint stiffness rehabilitation. Results: After applying the inclusion and exclusion criteria, four articles were included from PubMed and none from Medline or LILACS. Of the four PubMed articles, two were systematic reviews and two were randomized clinical trials. Conclusion: Articulated elbow orthoses can benefit joint stiffness treatment, improving range of motion and pain, showing superior effect compared to non-articulated plaster orthotics. Level of Evidence III, Systematic Review of Level III Studies.


RESUMO A rigidez articular é a principal complicação do cotovelo, afetando o tratamento e o prognóstico. O manejo da contratura articular se baseia na sua etiologia, e a intervenção precoce deve modificar o desfecho dessa complicação. Objetivo: Revisar artigos sobre órtese articulada de cotovelo para reabilitação de rigidez articular. Métodos: Foi realizada uma revisão bibliográfica em periódicos disponíveis do PubMed, Medline e LILACS, utilizando os Descritores em Ciências da Saúde (DeCS): aparelhos ortopédicos; braquetes; cotovelo; articulação do cotovelo; contratura; e transtornos da articulação. A intenção foi estabelecer e conhecer estudos de alto poder de evidência já realizados, que tenham tido como referência a temática de órteses articuladas de cotovelo para reabilitação de rigidez articular. Resultados: Após a aplicação dos critérios de inclusão e exclusão, revisaram-se artigos indexados no PubMed, Medline e LILACS, encontrando-se quatro artigos pelo PubMed e nenhum pelo Medline ou LILACS. Dos quatro artigos, dois eram revisões sistemáticas e dois eram ensaios clínicos randomizados. Conclusão: Órteses articuladas de cotovelo podem ser benéficas no tratamento de rigidez articular, sendo sugerido que melhoram amplitude de movimentos (ADM) e dor, inclusive com efeito superior em relação às órteses não articuladas gessadas. Nível de Evidência III, Revisão Sistemática de Estudos de Nível III.

2.
Rev. bras. ortop ; 51(3): 261-267, tab, graf
Artigo em Inglês | LILACS | ID: lil-787727

RESUMO

OBJECTIVE: To correlate the functional outcomes and radiographic indices of proximal humerus fractures treated using an anatomical locking plate for the proximal humerus. METHODS: Thirty-nine patients with fractures of the proximal humerus who had been treated using an anatomical locking plate were assessed after a mean follow-up of 27 months. These patients were assessed using the University of California Los Angeles (UCLA) score and their range of motion was evaluated using the method of the American Academy of Orthopedic Surgeons on the operated shoulder and comparative radiographs on both shoulders. The correlation between radiographic measurements and functional outcomes was established. RESULTS: We found that 64% of the results were good or excellent, according to the UCLA score, with the following means: elevation of 124°; lateral rotation of 44°; and medial rotation of thumb to T9. The type of fracture according to Neer's classification and the patient's age had significant correlations with the range of motion, such that the greater the number of parts in the fracture and the greater the patient's age were, the worse the results also were. Elevation and UCLA score were found to present associations with the anatomical neck-shaft angle in anteroposterior view; fractures fixed with varus deviations greater than 15° showed the worst results (p < 0.001). CONCLUSION: The variation in the neck-shaft angle measurements in anteroposterior view showed a significant correlation with the range of motion; varus deviations greater than 15° were not well tolerated. This parameter may be one of the predictors of functional results from proximal humerus fractures treated using a locking plate.


OBJETIVO: Correlacionar os resultados funcionais e os índices radiográficos das fraturas do úmero proximal tratadas com placa anatômica bloqueada para úmero proximal. MÉTODOS: Examinaram-se 39 pacientes com fraturas do úmero proximal tratados com placa anatômica bloqueada, com seguimento médio de 27 meses. Esses pacientes foram submetidos à análise do escore da Universidade da Califórnia de Los Angeles (UCLA) e à avaliação do arco de movimento pelo método da Academia Americana de Cirurgiões Ortopédicos no ombro operado e a exames radiográficos comparativos de ambos os ombros. Estabeleceu-se a correlação entre as medidas radiográficas e os resultados funcionais. RESULTADOS: Obtivemos 64% de bons e excelentes resultados conforme o escore da UCLA, com médias de 124° de elevação; 44° de rotação lateral; e polegar-T9 de rotação medial. O tipo de fratura, de acordo com a classificação de Neer, e a idade do paciente tiveram significativa correlação com o arco de movimentos; quanto maiores o número de partes das fraturas e a idade dos pacientes, piores os resultados. Encontrou-se associação entre a elevação e o escore da UCLA com o ângulo cervicodiafisário na incidência anteroposterior; as fraturas fixadas com desvios em varo maiores do que 15° apresentaram os piores resultados (p < 0,001). CONCLUSÃO: A variação da medida do ângulo cervicodiafisário na incidência anteroposterior mostrou significativa correlação com o arco de movimento; desvios em varo maiores do que 15° não foram bem tolerados. Esse parâmetro pode ser um dos preditores dos resultados funcionais nas fraturas do úmero proximal tratadas com placa anatômica bloqueada.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Fixação Interna de Fraturas , Fraturas do Ombro/cirurgia , Avaliação de Resultados em Cuidados de Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA