Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
J. bras. pneumol ; 47(2): e20200134, 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1154699

RESUMO

ABSTRACT Objective: To investigate the validity of field walking tests to identify exercise-induced hypoxemia and to compare cardiorespiratory responses and perceived effort between laboratory-based and field-based exercise tests in subjects with bronchiectasis. Methods: This was a cross-sectional study involving 72 non-oxygen-dependent participants (28 men; mean age = 48.3 ± 14.5 years; and mean FEV1 = 54.1 ± 23.4% of the predicted value). The participants underwent cardiopulmonary exercise testing (CPET) on a treadmill and constant work-rate exercise testing (CWRET) on the same day (1 h apart). In another visit, they underwent incremental shuttle walk testing (ISWT) and endurance shuttle walk testing (ESWT; 1 h apart). Desaturation was defined as a reduction in SpO2 ≥ 4% from rest to peak exercise. Results: CPET results were compared with ISWT results, as were CWRET results with ESWT results. There was no difference in the magnitude of desaturation between CPET and ISWT (−7.7 ± 6.3% vs. −6.6 ± 5.6%; p = 0.10) and between CWRET and ESWT (−6.8 ± 5.8% vs. −7.2 ± 6.3%; p = 0.50). The incremental tests showed an agreement in the magnitude of desaturation in the desaturation and no desaturation groups (42 and 14 participants, respectively; p < 0.01), as did the endurance tests (39 and 16 participants; p < 0.01). The magnitude of desaturation was similar among the participants who did or did not reach at least 85% of the maximum predicted HR. Conclusions: Field exercise tests showed good precision to detect desaturation. Field tests might be an alternative to laboratory tests when the clinical question is to investigate exercise-induced desaturation in subjects with bronchiectasis.


RESUMO Objetivo: Investigar a validade dos testes de caminhada de campo para identificar dessaturação durante o exercício, comparando os testes de exercício laboratoriais e clínicos de campo quanto às respostas cardiorrespiratórias e percepção de esforço em indivíduos com bronquiectasia não fibrocística. Métodos: Estudo transversal com 72 participantes não dependentes de oxigênio (28 homens; média de idade: 48,3 ± 14,5 anos; média do VEF1: 54,1 ± 23,4% do previsto). Os participantes foram submetidos ao teste de exercício cardiopulmonar (TECP) incremental em esteira e ao constant work-rate exercise testing (CWRET, teste de exercício com carga constante) em esteira, com intervalo de 1 h. Em outra visita, foram submetidos ao incremental shuttle walk test (ISWT, teste de caminhada incremental) e ao endurance shuttle walk test (ESWT, teste de caminhada de resistência), com intervalo de 1 h. A definição de dessaturação foi uma redução da SpO2 ≥ 4% do repouso ao pico do exercício. Resultados: O TECP e o ISWT resultaram em dessaturação de magnitude comparável (−7,7 ± 6,3% vs. −6,6 ± 5,6%; p = 0,10), assim como o fizeram o CWRET e o ESWT (−6,8 ± 5,8% vs. −7,2 ± 6,3%; p = 0,50). Houve concordância entre o TECP e o ISWT quanto ao número de participantes que apresentaram e não apresentaram dessaturação, respectivamente (42 e 14; p < 0,01), bem como entre o CWRET e o ESWT (39 e 16; p < 0,01). A magnitude da dessaturação foi semelhante nos participantes que atingiram ≥ 85% da FC máxima prevista ou não. Conclusões: Os testes de exercício de campo apresentaram boa precisão para detectar dessaturação. Os testes de campo podem ser uma alternativa aos testes de laboratório quando o objetivo é investigar a dessaturação durante o exercício em indivíduos com bronquiectasia.


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Bronquiectasia , Teste de Esforço , Consumo de Oxigênio , Volume Expiratório Forçado , Estudos Transversais , Caminhada , Tolerância ao Exercício , Laboratórios
2.
Fisioter. Pesqui. (Online) ; 25(4): 395-403, out.-dez. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-975350

RESUMO

ABSTRACT The performances of healthy individuals in an incremental shuttle walking test performed in a hallway (ISWT-H) and on a treadmill (ISWT-T) were compared to assess their physiological responses during aerobic training sessions with the speeds estimated from both tests. This was a cross-sectional study with 55 healthy subjects, who were randomized to perform the ISWT tests with 24 hours between them. Training sessions were held using a treadmill at 75% of the speeds obtained from the ISWT-H and ISWT-T. Measurements included walking distance, oxygen uptake (VO2), carbon dioxide (VCO2) production, heart rate (HR), and ventilation (VE). There was a significant difference between walking distances (ISWT-T: 823.9±165.2 m and ISWT-H:685.4±141.4 m), but similar physiological responses for VO2 (28.6±6.6 vs. 29.0±7.3 ml-1.kg-1.min-1), VCO2 (1.9±0.7 vs. 1.9±0.5 1), HR (158.3±17.8 vs. 158.6±17.7 bpm), and VE (41.5±10.4 vs. 43.7±12.9 1). The estimated speeds were different for the training sessions (5.5±0.5 km/h and 4.9±0.3 km/h), as well as the VO2, VCO2, VE, and HR. It was concluded that in healthy young adults, ISWTs carried out in a hallway and on a treadmill are not interchangeable. Since the ISWT-H was determined to have lower speed, the training intensity based on this test may underestimate a patient's responses to aerobic training.


RESUMO Comparou-se o desempenho no shuttle walk teste incremental realizado no corredor (SWTI-C) e na esteira (SWTI-E) em indivíduos saudáveis e comparar as respostas fisiológicas durante as sessões de treinamento aeróbio com as velocidades estimadas em ambos os testes. Trata-se de um estudo transversal com cinquenta e cinco participantes saudáveis. Os participantes foram randomizados para realizar os testes com 24 horas de intervalo. As sessões de treinamento foram realizadas na esteira com 75% da velocidade obtida no SWTI-C e no SWTI-E. As avaliações incluíram a distância da caminhada, consumo de oxigênio (VO2), produção de dióxido de carbono (VCO2), frequência cardíaca (FC) e ventilação (VE). Houve uma diferença significante entre as distâncias caminhadas (SWTI-E: 823,9 ± 165,2 m e SWTI-C: 685,4 ± 141,4 m), mas respostas fisiológicas semelhantes para o VO2 (28,6 ± 6,6 vs. 29,0 ± 7,3 ml-1.kg-1.min-1), VCO2 (1,9 ± 0,7 vs. 1,9 ± 0,5 1), HR (158,3 ± 17,8 vs. 158,6 ± 17,7 bpm) e VE (41,5 ± 10,4 vs. 43,7 ± 12,9 1). As velocidades estimadas foram diferentes para as sessões de treinamento (5,5 ± 0,5xkm/h e 4,9 ± 0,3 km/h), assim como o VO2, VCO2, VE e FC. Concluiu-se que em adultos jovens saudáveis, SWTI realizados no corredor e na esteira não são intercambiáveis. Uma vez que o SWTI-E determinou uma menor velocidade, a intensidade do treinamento baseada neste teste pode subestimar as respostas de um paciente ao treinamento aeróbio.


RESUMEN Se trata de una comparación del rendimiento en la prueba incremental shuttle walk llevado a cabo en el pasillo (SWPI-P) y en la cinta caminadora (SWPC) entre individuos sanos, para evaluar las respuestas fisiológicas durante las sesiones de entrenamiento aeróbico con velocidades estimadas en ambas pruebas. Estudio transversal con 55 individuos sanos. A los participantes se les eligieron al azar para realizar las pruebas con intervalo de 24 horas. Se llevaron a cabo sesiones de entrenamiento en la cinta caminadora con el 75 % de la velocidad obtenida en SWPI-P y en SWPC. Se incluyen entre las evaluaciones la distancia de la caminata, el consumo de oxígeno (VO2), la producción de dióxido de carbono (VCO2), la frecuencia cardiaca (FC) y la ventilación (VE). Hubo una diferencia significativa entre las distancias recorridas (SWPC: 823,9 ± 165,2 m y SWPI-P: 685,4 ± 141,4 m), pero similares a las respuestas fisiológicas del VO2 (28,6 ± 6,6 vs. 29,0 ± 7,3 ml-1.kg-1. min-1), VCO2 (1,9 ± 0,7 vs. ± 1,9 0,5 1), HR (158,3 ± 17,8 vs. 158,6 ± 17,7 bpm) y VE (41,5 ± 10,4 vs. 43,7 ± 12,9 1). Las velocidades estimadas fueron diferentes en las sesiones de entrenamiento (5,5 ± 0,5 km/h y 4,9 ± 0,3 km/h), así como VO2, VCO2, VE y FC. Se concluyó que, en los adultos jóvenes sanos, la SWPI llevada a cabo en el pasillo y en la cinta caminadora no pueden ser intercambiables. Dado que la SWPC determinó una menor velocidad, la intensidad de entrenamiento de esta prueba puede subestimar las respuestas de un paciente en el entrenamiento aeróbico.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA