Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. bras. cir. cardiovasc ; 36(6): 752-759, Nov.-Dec. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1351675

RESUMO

Abstract Introduction: Reoperations in cardiac surgery represent a clinical challenge, particularly because of the higher rate of perioperative morbidity and mortality. Mitral valve reoperation owing to bioprosthesis dysfunction, transcatheter treatment with a prosthesis implantation over the prosthesis has emerged as an alternative, especially for patients with a previous approach. In this study, we analyzed the hydrodynamic behavior of transcatheter prosthesis implantation in conventional mitral bioprostheses through hydrodynamic tests and produced a recommendation for the size of transcatheter valve most adequate for valve-in-valve procedure. Methods: Mitral bioprostheses were attached to a flow duplicator and different combinations of transcatheter prostheses were implanted inside. The equipment simulates the hydrodynamic behavior of the valves submitted in vitro and determines transvalvular pressures and flow parameters. Results: All tests could be performed. Better hydrodynamic performance occurred for transcatheter prostheses 1 mm smaller than bioprostheses, except for the 27-mm bioprostheses. Effective valve areas (cm²) and transvalvular gradients (mmHg) were, respectively: Bioprosthesis × Inovare: 27 × 28 mm: 1.65 and 5.95/29 × 28 mm and 31 × 30 mm: 2.15 and 3.6. Conclusion: The mitral valve-in-valve implantation proved to be feasible in vitro. The use of 27-mm bioprostheses should be judicious, with preference for a 26-mm transcatheter valve. In the 29 and 31-mm bioprostheses, the implantation was very satisfactory, with good effective valve areas and transvalvular gradients, with preference for smaller transcatheter valves.


Assuntos
Humanos , Bioprótese , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Desenho de Prótese , Brasil , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Hidrodinâmica , Valva Mitral/cirurgia
2.
Rev. bras. cir. cardiovasc ; 30(5): 562-570, Sept.-Oct. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-769899

RESUMO

ABSTRACT OBJECTIVE: Engage the UNIFESP Cardiovascular Surgery residents in coronary anastomosis, assess their skills and certify results, using the Arroyo Anastomosis Simulator and UNIFESP surgical models. METHODS: First to 6th year residents attended a weekly program of technical training in coronary anastomosis, using 4 simulation models: 1. Arroyo simulator; 2. Dummy with a plastic heart; 3. Dummy with a bovine heart; and 4. Dummy with a beating pig heart. The assessment test was comprised of 10 items, using a scale from 1 to 5 points in each of them, creating a global score of 50 points maximum. RESULTS: The technical performance of the candidate showed improvement in all items, especially manual skill and technical progress, critical sense of the work performed, confidence in the procedure and reduction of the time needed to perform the anastomosis after 12 weeks practice. In response to the multiplicity of factors that currently influence the cardiovascular surgeon training, there have been combined efforts to reform the practices of surgical medical training. CONCLUSION: 1 - The four models of simulators offer a considerable contribution to the field of cardiovascular surgery, improving the skill and dexterity of the surgeon in training. 2 - Residents have shown interest in training and cooperate in the development of innovative procedures for surgical medical training in the art.


Assuntos
Humanos , Inovação Organizacional , Medicina Estatal , Mídias Sociais , Objetivos Organizacionais , Reino Unido
3.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 23(3): 134-137, jul.-set. 2010. ilus
Artigo em Português | LILACS | ID: lil-567759

RESUMO

O marcapasso transvenoso temporário é uma terapêutica de ampla aplicabilidade, raramente levando a complicação tanto fatais quanto não-fatais, sendo que essas últimas podem resultar em situações inesperadas, criando dificuldades para o implante do dispositivo definitivo a ser empregado; dentre elas, destaca-se a formação de looping e nós no eletrodo, complicações essas pouco relatadas na literatura. Os casos a seguir mostram dois pacientes que apresentaram bloqueio atrioventricular total (BAVT), sendo observada a formação de loopings e nós no eletrodo temporário. Mesmo assim, optou-se por implantar os dispositivos, seguindo as orientações Diretrizes Brasileiras de Dispositivos Cardíacos Eletrônicos Implantáveis (DCEI), mudando a estratégia cirúrgica.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estimulação Cardíaca Artificial/métodos , Estimulação Cardíaca Artificial , Marca-Passo Artificial/efeitos adversos , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA