Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Korean Journal of Blood Transfusion ; : 21-29, 1998.
Artigo em Coreano | WPRIM | ID: wpr-154100

RESUMO

BACKGROUND: Current blood and blood components are prepared from 320ml or 400ml blood collection. The analytic values and standard values of blood and blood components were evaluated at Seo-Bu Blood Center, The Republic of Korea National Red Cross, Seoul, Korea. METHODS: Blood and blood components were analyzed with weight, specific gravity, content volume, RBC counts, WBC counts, platelets counts, hemoglobin, hematocrit, pH, total protein, albumin, factor VII and bacterial culture. RESLUTS: The volume, hemoglobin, hematocrit and pH of 320ml and 400ml standard unit of whole blood was 328 +/- 31ml and 405 +/- 22ml, 12.7 +/- 1.7g/dl and 14.8 +/- 2.0g/dl, 38.0 +/- 4.0% and 40.8 +/- 4.6%, mean of 7.16 and 7.13, respectively. The volume and hematocrit of packed red cells prepared from 320ml and 400ml standard unit of whole blood was 188 +/- 23ml and 248 +/- 23ml, 73.2 +/- 4.7% and 72.6 +/- 5.4%, respectively. Leukocytes poor red cells from 400ml standard unit of whloe blood showed 225 +/- 12ml of volume, 71 +/- 2.4% of hematocrit, and WBC removal was 87 +/- 5%. The volume, hematocrit and total protein in washed red cells was 224 +/- 11ml, 59 +/- 6.0% and 0.10 +/- 0.05g/unit, respectively. Leukocytes concentrates revealed 50 +/- 4.6ml of volume, 2.0 +/- 0.5x109/unit of WBC count and WBC recovery was 78 +/- 6.0%. Platelet concentrates prepared from 320ml and 400ml standard unit of fresh whole blood showed 38 +/- 3ml and 48 +/- 3ml of volume, 4.68 +/- 1.60x1010 and 5.55 +/- 1.80x1010 of platelet per unit, and 7.05 +/- 0.25 and 6.95 +/- 0.34 of pH, respectively. The fresh frozen plasma from 320ml standard unit of whole blood contained 143 +/- 25ml of volume, and that from 400ml whole blood showed 161 +/- 27ml of volume and 112 +/- 33 IU/unit of factor VII. The cryoprecipitate from 320ml whole blood showed 42 +/- 3ml of volume and 81 +/- 9 IU/unit of factor VII. There were no bacterial growth for all the components inoculated. CONCLUSION: At Seo-Bu Blood Center, we evaluated the characteristics of current blood and blood components, and established the standard values for whole blood (320ml, 400ml) as well as packed red cells, leukocytes poor red cells, washed red cells, leukocyte concentrates, platelet concentrates, fresh fozen plasma and cryoprecipates from 320ml and 400ml whole blood based on the present studies. Compared to the Standards for Blood Banks and Transfusion Services, American Association of Blood Banks, values of evluated items of current blood and blood components showed comparable results, but platelet counts from 320ml collection did not meet to those standards.


Assuntos
Bancos de Sangue , Plaquetas , Fator VII , Hematócrito , Concentração de Íons de Hidrogênio , Coreia (Geográfico) , Leucócitos , Plasma , Contagem de Plaquetas , Cruz Vermelha , República da Coreia , Seul , Gravidade Específica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA