Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Journal of the Korean Radiological Society ; : 149-161, 2022.
Artigo em Inglês | WPRIM | ID: wpr-916899

RESUMO

Purpose@#To investigate the correlation between computer-aided diagnosis (CAD) parameters in 3-tesla (T) MRI and pathologic immunohistochemical (IHC) markers in invasive carcinoma of no special type (NST). @*Materials and Methods@#A total of 94 female who were diagnosed with NST carcinoma and underwent 3T MRI using CAD, from January 2018 to April 2019, were included. The relationship between angiovolume, curve peak, and early and late profiles of dynamic enhancement from CAD with pathologic IHC markers and molecular subtypes were retrospectively investigated using Dwass, Steel, Critchlow-Fligner multiple comparison analysis, and univariate binary logistic regression analysis. @*Results@#In NST carcinoma, a higher angiovolume was observed in tumors of higher nuclear and histologic grades and in lymph node (LN) (+), estrogen receptor (ER) (-), progesterone receptor (PR) (-), human epidermal growth factor 2 (HER2) (+), and Ki-67 (+) tumors. A high rate of delayed washout and a low rate of delayed persistence were observed in Ki-67 (+) tumors. In the binary logistic regression analysis of NST carcinoma, a high angiovolume was significantly associated with a high nuclear and histologic grade, LN (+), ER (-), PR (-), HER2 (+) status, and non-luminal subtypes. A high rate of washout and a low rate of persistence were also significantly correlated with the Ki-67 (+) status. @*Conclusion@#Angiovolume and delayed washout/persistent rate from CAD parameters in contrast enhanced breast MRI correlated with predictive IHC markers. These results suggest that CAD parameters could be used as clinical prognostic, predictive factors.

2.
Journal of the Korean Radiological Society ; : 717-727, 2019.
Artigo em Inglês | WPRIM | ID: wpr-916752

RESUMO

PURPOSE@#To investigate the correlation of the strain elasticity of breast cancer with histologic features, immunohistochemical markers and molecular subtypes that are known to be factors related to prognosis.@*MATERIALS AND METHODS@#B-mode ultrasound and strain elastography were performed in 123 patients (mean age, 53.4; range, 28–82) with invasive ductal carcinoma (IDC) (mean size, 1.54 cm; range, 0.4–7.0 cm). Histologic grade, lymph node (LN) status, lymphovascular invasion, immunohistochemical biomarkers [estrogen receptor, progesterone receptor, human epidermal growth factor receptor 2 (HER2), CK5/6, epidermal growth factor receptor, and Ki-67] and molecular subtypes were determined from surgical pathology reports. The relationships between these factors and elasticity scores were evaluated.@*RESULTS@#LN involvement was associated with a higher elasticity score which was statistically significant (p = 0.042). The tumor size, lymphovascular invasion, histologic grades, immunohistochemical markers and molecular subtypes had no significant correlation with the elasticity score (p > 0.05 for all). However, the IDCs with larger size and a positive lymphovascular invasion tended to have higher elasticity scores. Furthermore, higher histologic grade cancers and the HER2 overexpression-type tended to have lower elasticity scores.@*CONCLUSION@#The elasticity score of IDC had a significant correlation with LN involvement but no statistically significant correlation with the histologic features, immunohistochemical markers or molecular subtypes.

3.
Chonnam Medical Journal ; : 133-139, 2017.
Artigo em Inglês | WPRIM | ID: wpr-788373

RESUMO

Invasive lobular carcinoma (ILC) is the second most common kind of breast cancer. Diffusion weighted imaging (DWI) and positron emission tomography/computed tomography (PET/CT) are functional modalities for presenting the biological characteristics of breast cancer. The purpose of this article is to study the relationship between DWI or PET/CT and ILC's prognostic factors. The relationship between the apparent diffusion coefficient (ADC) values, standard uptake value (SUV)max and prognostic factors of ILC were statistically evaluated. The ADC values were lower in mass types of ILC. SUVmax was statistically higher in grade 3 and 4 background parenchymal enhancement and positive lymph node metastasis. ADC values of DWI and SUVmax of PET/CT can be helpful in the prediction of the prognosis of ILC.


Assuntos
Mama , Neoplasias da Mama , Carcinoma Lobular , Difusão , Imagem de Difusão por Ressonância Magnética , Elétrons , Linfonodos , Imageamento por Ressonância Magnética , Metástase Neoplásica , Características da População , Tomografia por Emissão de Pósitrons , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Prognóstico
4.
Chonnam Medical Journal ; : 133-139, 2017.
Artigo em Inglês | WPRIM | ID: wpr-151393

RESUMO

Invasive lobular carcinoma (ILC) is the second most common kind of breast cancer. Diffusion weighted imaging (DWI) and positron emission tomography/computed tomography (PET/CT) are functional modalities for presenting the biological characteristics of breast cancer. The purpose of this article is to study the relationship between DWI or PET/CT and ILC's prognostic factors. The relationship between the apparent diffusion coefficient (ADC) values, standard uptake value (SUV)max and prognostic factors of ILC were statistically evaluated. The ADC values were lower in mass types of ILC. SUVmax was statistically higher in grade 3 and 4 background parenchymal enhancement and positive lymph node metastasis. ADC values of DWI and SUVmax of PET/CT can be helpful in the prediction of the prognosis of ILC.


Assuntos
Mama , Neoplasias da Mama , Carcinoma Lobular , Difusão , Imagem de Difusão por Ressonância Magnética , Elétrons , Linfonodos , Imageamento por Ressonância Magnética , Metástase Neoplásica , Características da População , Tomografia por Emissão de Pósitrons , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Prognóstico
5.
Korean Journal of Radiology ; : 1006-1011, 2015.
Artigo em Inglês | WPRIM | ID: wpr-163303

RESUMO

OBJECTIVE: To evaluate the sonographic features of invasive apocrine carcinoma (IAC) of the breast. MATERIALS AND METHODS: This study included five pathologically proven cases of IAC, and their sonographic features were retrospectively analyzed according to the Breast Imaging Reporting and Data System (BI-RADS) lexicon. RESULTS: All five lesions involved the left breast and were seen as irregularly shaped masses. All lesions, except one, had a parallel orientation to the chest wall. All five lesions showed noncircumscribed margins and heterogeneous echotexture; however, they showed various posterior features. One lesion had edema as an associated feature. Sonographic assessments were classified as BI-RADS category 4 in all five cases. CONCLUSION: Invasive apocrine carcinoma sonographic findings are difficult to differentiate from those of invasive ductal carcinoma of no special type.


Assuntos
Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Glândulas Apócrinas/patologia , Neoplasias da Mama/diagnóstico , Carcinoma/diagnóstico , Invasividade Neoplásica , Tomografia por Emissão de Pósitrons , Receptor ErbB-2/metabolismo , Receptores de Estrogênio/metabolismo , Receptores de Progesterona/metabolismo , Tomografia Computadorizada por Raios X , Proteína Supressora de Tumor p53/metabolismo
6.
Korean Journal of Radiology ; : 403-410, 2014.
Artigo em Inglês | WPRIM | ID: wpr-109973

RESUMO

OBJECTIVE: The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. MATERIALS AND METHODS: Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. RESULTS: The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. CONCLUSION: Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Artefatos , Mama/patologia , Neoplasias da Mama/patologia , Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Variações Dependentes do Observador , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
7.
Journal of Breast Cancer ; : 322-328, 2013.
Artigo em Inglês | WPRIM | ID: wpr-52976

RESUMO

PURPOSE: We aimed to determine the sensitivity of computer-aided detection (CAD) applied to digital mammography in asymptomatic and symptomatic breast cancer patients. METHODS: We retrospectively analyzed digital mammography and CAD images from 210 patients diagnosed with breast cancer. The patients were divided into symptomatic and asymptomatic groups. The sensitivity of CAD in both groups was assessed in relation to breast tissue density, histopathological type of breast cancer, and tumor size. RESULTS: The detection rate of the CAD system was 87.8% in the asymptomatic group. The sensitivity in different tissue densities was 100% in fatty breasts (P1), 88.9% with scattered fibroglandular densities (P2), 94.4% in heterogeneously dense breasts (P3), and 66.7% in extremely dense breasts (P4). The detection rate of the CAD system in the symptomatic group was 87.2%, and the sensitivity was 90.5%, 90%, 86.6%, and 75% in P1-P4 breasts, respectively. In the asymptomatic group, the CAD system detected 90.3% of invasive ductal carcinomas, not otherwise specified (IDC-NOS) and 88.9% of ductal carcinomas in situ (DCIS), but did not detect other types of malignancy. In the symptomatic group, the CAD system detected 88.2% of IDC-NOS, 88.9% of DCIS and 75% of other types of malignancy. When analyzed according to tumor size, the sensitivity of CAD in the asymptomatic and symptomatic groups was 82.6% and 83.3% for tumors 2 cm. CONCLUSION: The sensitivity of CAD was low in P4 breasts and high for tumors larger than 2 cm, with no statistically significant differences between the asymptomatic and symptomatic groups for IDC-NOS and DCIS. CAD showed greater sensitivity for other neoplasms in symptomatic patients.


Assuntos
Humanos , Mama , Neoplasias da Mama , Carcinoma Ductal , Carcinoma Intraductal não Infiltrante , Diagnóstico por Computador , Mamografia , Estudos Retrospectivos
8.
Korean Journal of Radiology ; : 711-717, 2013.
Artigo em Inglês | WPRIM | ID: wpr-209706

RESUMO

OBJECTIVE: The aim of this study is to evaluate the clinical characteristics and ultrasonographic findings of band-like interposing fat as well as to identify additional approaches for its diagnosis. MATERIALS AND METHODS: This study included 26 confirmed cases of band-like interposing fat from June 2008 to June 2010. A retrospective analysis was performed to evaluate the clinical characteristics and ultrasonographic findings in these cases. Five radiologists analyzed the ultrasonographic findings, which correlated with the mammographic and MRI findings when available, according to Breast Imaging Reporting and Data System classification. RESULTS: None of the 26 patients had any symptoms. In 92.3% of the patients, the lesion was located in the upper outer quadrant of the breast. The mean distance of the lesion from the nipple was 2.4 +/- 0.7 cm (1.1-4.5). The mean depth of the lesion from the skin was 1.3 +/- 0.3 cm (0.8-2.1). The mean maximal length of the lesion was 0.8 +/- 0.4 cm (0.3-1.8). The following were the most frequent ultrasonographic findings of lesions: irregular shape, not parallel orientation, indistinct margins, abrupt interface, hypoechogenicity, no posterior feature, no calcification, and presence of vascularity. The most frequent BI-RADS category was 4a. There were no suspicious findings on the mammography or MRI. CONCLUSION: Ultrasonographic findings may lead to misclassification of band-like interposing fat as a malignancy. A better understanding of the clinical and ultrasonographic characteristics of band-like interposing fat would facilitate its differentiation from a true mass.


Assuntos
Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Gravidez , Adulto Jovem , Tecido Adiposo/diagnóstico por imagem , Biópsia por Agulha Fina , Doenças Mamárias/patologia , Diagnóstico Diferencial , Erros de Diagnóstico , Artéria Torácica Interna/diagnóstico por imagem , Estudos Retrospectivos , Ultrassonografia Mamária/métodos
9.
Korean Journal of Radiology ; : 113-121, 2011.
Artigo em Inglês | WPRIM | ID: wpr-36586

RESUMO

The purpose of this paper is to show the clinical and radiologic features of a variety of diffuse, infiltrative breast lesions, as well to review the relevant literature. Radiologists must be familiar with the various conditions that can diffusely involve the breast, including normal physiologic changes, benign disease and malignant neoplasm.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Doenças Mamárias/diagnóstico , Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética , Mamografia , Tomografia Computadorizada por Raios X , Ultrassonografia Mamária
10.
Korean Journal of Radiology ; : 149-155, 2010.
Artigo em Inglês | WPRIM | ID: wpr-127083

RESUMO

OBJECTIVE: To evaluate the interobserver variability and performance in the interpretation of ultrasonographic (US) findings of thyroid nodules. MATERIALS AND METHODS: 72 malignant nodules and 61 benign nodules were enrolled as part of this study. Five faculty radiologists and four residents independently performed a retrospective analysis of the US images. The observers received one training session after the first interpretation and then performed a secondary interpretation. Agreement was analyzed by Cohen's kappa statistic. Degree of performance was analyzed using receiver operating characteristic (ROC) curves. RESULTS: Agreement between the faculties was fair-to-good for all criteria; however, between residents, agreement was poor-to-fair. The area under the ROC curves was 0.72, 0.62, and 0.60 for the faculties, senior residents, and junior residents, respectively. There was a significant difference in performance between the faculties and the residents (p < 0.05). There was a significant increase in the agreement for some criteria in the faculties and the senior residents after the training session, but no significant increase in the junior residents. CONCLUSION: Independent reporting of thyroid US performed by residents is undesirable. A continuous and specialized resident training is essential to enhance the degree of agreement and performance.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Competência Clínica/estatística & dados numéricos , Diagnóstico Diferencial , Docentes de Medicina/estatística & dados numéricos , Internato e Residência/estatística & dados numéricos , Variações Dependentes do Observador , Curva ROC , Radiologia/educação , Estudos Retrospectivos , Sensibilidade e Especificidade , Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem
11.
Journal of the Korean Society of Medical Ultrasound ; : 1-5, 2010.
Artigo em Coreano | WPRIM | ID: wpr-725610

RESUMO

PURPOSE: We wanted to evaluate the sensitivity and specificity of screening mammography and ultrasonography for breast examinations and we assessed the clinical usefulness of breast ultrasound for cancer screening. MATERIALS AND METHODS: Of all the women who visited the health promotion center of seven medical institutions from Mar 2004 to Feb 2005, we compared the sensitivity and specificity between a single use of mammography and mammography with ultrasonography for the patients who underwent both mammography and ultrasonography. Here, the reference criteria were the follow-up and the histopathology, which were performed after one year. RESULTS: A total of 1123 patients underwent both mammography and ultrasonography and they could be followed up for a year. For the 1123 patients who underwent both mammography and ultrasonography, the sensitivity and specificity of a single use of mammography were 14.3% and 86.9%, respectively. The sensitivity and specificity of mammography with ultrasonography were 85.7% and 85.9%, respectively. These results showed that the sensitivity was significantly increased when mammography was combined with ultrasonography (< 0.05). CONCLUSION: The sensitivity was improved for the cases that underwent both mammography and ultrasonography.


Assuntos
Feminino , Humanos , Mama , Detecção Precoce de Câncer , Seguimentos , Promoção da Saúde , Mamografia , Programas de Rastreamento , Sensibilidade e Especificidade
12.
Nuclear Medicine and Molecular Imaging ; : 40-47, 2009.
Artigo em Coreano | WPRIM | ID: wpr-59151

RESUMO

PURPOSE: Differentiated thyroid cancer (DTC) has variable degree of F-18 FDG avidity. The purpose of this study was to evaluate the relationship between F-18 FDG uptake and pathological or immunohistochemical features of DTC. MATERIALS AND METHODS: DTC patients who underwent both pre-operative F-18 FDG PET/CT scan and surgery were included in the study. Maximum standardized uptake values (SUVmax) of primary tumor were calculated. If the primary tumor showed no perceptibly increased F-18 FDG uptake, region of interest was drawn based on finding of CT portion of the PET/CT images. Pathological and immunohistochemical markers such as presence of lymph node (LN) metastasis and underlying thyroiditis, tumor size, Ki-67 labeling index, expressions of EGFR, COX-2, and Galectin-3 were evaluated. RESULTS: Total of 106 patients was included (102 papillary carcinomas, 4 follicular carcinomas). The mean SUVmax of the large tumors (above 1 cm) was significantly higher than the mean SUVmax of small (equal to or less than 1 cm) ones (7.8+/-8.5 vs. 3.6+/-3.1, p=0.004). No significant difference in F-18 FDG uptake was found according to the presence or absence of LN metastasis and underlying thyroiditis, or the degree of Ki-67 labeling index, expression of EGFR, COX-2 and Galectin-3. CONCLUSION: In conclusion, the degree of F-18 FDG uptake in DTC was associated with the size of primary tumor. But there seem to be no relationship between F-18 FDG uptake of DTC and expression of Ki-67, EGFR, COX-2 and Galectin-3.


Assuntos
Humanos , Carcinoma Papilar , Galectina 3 , Linfonodos , Metástase Neoplásica , Glândula Tireoide , Neoplasias da Glândula Tireoide , Tireoidite
13.
Journal of the Korean Society of Medical Ultrasound ; : 103-107, 2008.
Artigo em Coreano | WPRIM | ID: wpr-725652

RESUMO

A Killian-Jamieson diverticulum is a type of pharyngoesophageal diverticuli and can be visualized on thyroid ultrasonography (US). Although most of the lesions are located in the deep layer of the left thyroid lobe, we encountered a case of a right-sided Killian-Jamieson diverticulum in a 64-year-old man that was mistaken for a thyroid nodule on US. We describe the US, computed tomographic, and esophagraphic findings of this case. In addition, we describe the US findings of a left Killian-Jamieson diverticulum in a 55-year-old woman that was seen as a hyperechoic mass in the thyroid on US.. The shape and echogenecity of the diverticulum changed with swallowing as depicted on real-time US and the need for a needle aspiration biopsy was avoided.


Assuntos
Feminino , Humanos , Pessoa de Meia-Idade , Biópsia por Agulha , Deglutição , Divertículo , Agulhas , Glândula Tireoide , Nódulo da Glândula Tireoide
14.
Korean Journal of Radiology ; : 397-402, 2007.
Artigo em Inglês | WPRIM | ID: wpr-174909

RESUMO

OBJECTIVE: This study aims to evaluate the degree of inter- and intraobserver agreement when characterizing breast abnormalities using the Breast Imaging Reporting and Data System (BI-RADS)-ultrasound (US) lexicon, as defined by the American College of Radiology (ACR). MATERIALS AND METHODS: Two hundred ninety three female patients with 314 lesions underwent US-guided biopsies at one facility during a two-year period. Static sonographic images of each breast lesion were acquired and reviewed by four radiologists with expertise in breast imaging. Each radiologist independently evaluated all cases and described the mass according to BI-RADS-US. To assess intraobserver variability, one of the four radiologists reassessed all of the cases one month after the initial evaluation. Inter- and intraobserver variabilities were determined using Cohen's kappa (k) statistics. RESULTS: The greatest degree of reliability for a descriptor was found for mass orientation (k = 0.61) and the least concordance of fair was found for the mass margin (k = 0.32) and echo pattern (k = 0.36). Others descriptive terms: shape, lesion boundary and posterior features (k = 0.42, k = 0.55 and k = 0.53, respectively) and the final assessment (k = 0.51) demonstrated only moderate levels of agreement. A substantial degree of intraobserver agreement was found when classifying all morphologic features: shape, orientation, margin, lesion boundary, echo pattern and posterior feature (k = 0.73, k = 0.68, k = 0.64, 0.68, k = 0.65 and k = 0.64, respectively) and rendering final assessments (k = 0.65). CONCLUSION: Although BI-RADS-US was created to achieve a consensus among radiologists when describing breast abnormalities, our study shows substantial intraobserver agreement but only moderate interobserver agreement in the mass description and final assessment of breast abnormalities according to its use. A better agreement will ultimately require specialized education, as well as self-auditing practice tests.


Assuntos
Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Adenocarcinoma/classificação , Adenocarcinoma Mucinoso/classificação , Biópsia , Neoplasias da Mama/classificação , Carcinoma Ductal de Mama/classificação , Carcinoma Intraductal não Infiltrante/classificação , Seguimentos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Radiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sociedades Médicas , Terminologia como Assunto , Ultrassonografia Doppler em Cores/estatística & dados numéricos , Ultrassonografia Mamária/estatística & dados numéricos
15.
Cancer Research and Treatment ; : 314-322, 2003.
Artigo em Inglês | WPRIM | ID: wpr-226928

RESUMO

PURPOSE: The biallelic expression of insulin-like growth factor-II (IGF2) and H19 has been reported to be associated with the progression of several tumors. Here, the promoter usage and expression levels of IGF2 and H19 are reported to be altered in cervical and endometrial cancers showing loss of imprinting (LOI). MATERIALS AND METHODS: The imprinting status of IGF2 and H19 was examined in 32 cervical carcinomas, their matched normal tissues, 13 endometrial cancer and 33 normal endometrial tissues. RESULTS: The LOI of IGF2 was observed in 7 of 18 (39%) and 1 of 13 (8.3%) informative cervical carcinomas and informative endometrial cancers, respectively. The LOI of the H19 gene was detected in 5 of 14 (36%) and in all 11 (100%) informative cervical carcinoma cases and informative endometrial cancer cases, respectively. The use of promoter P1 was observed in the LOI tumors of IGF2, but not in the tumors showing maintenance of IGF2 imprinting (MOI), or in cervical and endometrial cancers. Unlike MOI tumors, some LOI tumors revealed a lack of IGF2 transcription from the promoter P3. The LOI tumors of IGF2 showed increased expression of the IGF2 level, but a down-regulation of the H19, relative to normal tissues, whereas the MOI tumors revealed no significant alterations. CONCLUSION: These results suggest that the promoter P1 could be involved in the biallelic expression of IGF2, and that the altered expression of the IGF2 and H19 levels might be associated with the progression of cervical and endometrial cancers that exhibit biallelic IGF2 expression.


Assuntos
Feminino , Regulação para Baixo , Neoplasias do Endométrio , Neoplasias do Colo do Útero
16.
Journal of the Korean Society of Magnetic Resonance in Medicine ; : 21-27, 2002.
Artigo em Coreano | WPRIM | ID: wpr-169385

RESUMO

PURPOSE: To evaluate diffusion-weighted imaging findings of intracerebral hematoma according to the time sequence. MATERIALS AND METHODS: Seventeen patients with intracerebral hematoma were studied. Diffusion weighted images using 1.5 tesla MRI machine were obtained with b-value of 1000 sec/mm2. The patients were grouped as hyperacute stage(within 12 hours, 5 patients), acute stage(within 3 days, 4 patients), subacute stage(within 3 weeks, 4 patients), and chronic stage(after 3 weeks,4 patients). The signal intensities were analysed as bright, high, iso, low and dark at the central and peripheral portions of the hematoma in each stage, and compared with those of T2 and T1 weighted images. RESULTS: The signal intensities of the central and peripheral portion of the intracerebral hematoma on diffusion-weighted images were high and dark in hyperacute stage, dark and high-bright in acute stage, and high-bright and dark in subacute and chronic stages. The patterns of signal change of hematoma on diffusion-weighted image according to the time sequence were similar to those on T2-weighted image, but 1 early and prominently. CONCLUSION: The intracerebral hematoma on diffusion-weighted image showed unique central and peripheral signal intensity according to the time sequence. Central portions show high to bright signals in hyperacute, subacute and chronic stage, and dark signal in acute stage, and peripheral portions show dark signals in hyperacute, subacute and chronic stage, and high to bright signal in acute stage.


Assuntos
Humanos , Difusão , Hematoma , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA