Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Adicionar filtros








Intervalo de ano
1.
Archives of Craniofacial Surgery ; : 46-49, 2017.
Artigo em Inglês | WPRIM | ID: wpr-199175

RESUMO

Nevus sebaceus is a hamartoma of the sebaceous gland that occurs congenitally, from which various secondary tumors can arise with a prevalence of 5%–6%. Benign neoplasms commonly arise from nevus sebaceous, but they have a very low malignant potential. Two neoplasms may occasionally arise within the same lesion, but it is rare for three or more neoplasms to occur in a nevus sebaceus simultaneously. A 61-year-old male patient was admitted to our hospital for a 4 cm×2.5 cm growing tumor in a verrucous form arising within a periauricular nevus sebaceus in the post auricle of the left ear that had developed 30 years earlier. The nodule was diagnosed as 3 different types of tumors: trichilemmoma, desmoplastic trichilemmoma, and basal cell carcinoma. To our knowledge, this is the first report of the coexistence of three different tumors arising from nevus sebaceous. It contain malignant neoplasm also. Surgeons should be aware of the need for close monitoring and early complete surgical excision of sebaceous nevus in order to improve patient outcomes.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Carcinoma Basocelular , Orelha , Hamartoma , Nevo , Prevalência , Glândulas Sebáceas , Cirurgiões
2.
Archives of Plastic Surgery ; : 469-470, 2017.
Artigo em Inglês | WPRIM | ID: wpr-142211

RESUMO

No abstract available.

3.
Archives of Plastic Surgery ; : 469-470, 2017.
Artigo em Inglês | WPRIM | ID: wpr-142210

RESUMO

No abstract available.

4.
Archives of Craniofacial Surgery ; : 76-81, 2017.
Artigo em Inglês | WPRIM | ID: wpr-37809

RESUMO

BACKGROUND: A transcaruncular approach is typically used for reconstructions of medial wall fractures. However, others reported that a transconjunctival approach was conducive for securing an adequate surgical field of view. In this study, we aimed to examine the extent of repair of medial wall fracture via a transconjunctival approach. METHODS: We retrospectively reviewed the medical records of 50 patients diagnosed as having medial wall fracture via preoperative computed tomography and who underwent surgery between March 2011 and February 2014. The fracture location was defined by dividing each of the anterior-posterior and superior-inferior distances into three compartments. RESULTS: A transcaruncular approach was used in 7 patients, while the transconjunctival approach was performed in the remaining 43 patients. The transconjunctival approach enabled a relatively broad range of repair that partially included the front and back of the medial wall, and was successful in 86% of the entire study population. CONCLUSION: It is known that more than 50% of total cases of the medial wall fracture occur mainly in the middle-middle portion, a majority of which can be reconstructed via a transconjunctival approach. We used a transconjunctival approach in identifying the location of the fracture on image scans except for cases including the fracture of the superior portion in patients with medial wall fracture. If it is possible to identify the location of the fracture, a transconjunctival approach would be an useful method for the reconstruction in that it causes no damages to the lacrimal system and is useful in confirming the overall status of the floor.


Assuntos
Humanos , Prontuários Médicos , Métodos , Procedimentos Cirúrgicos Oftalmológicos , Fraturas Orbitárias , Implantes Orbitários , Procedimentos de Cirurgia Plástica , Estudos Retrospectivos
5.
Archives of Craniofacial Surgery ; : 137-140, 2017.
Artigo em Inglês | WPRIM | ID: wpr-131758

RESUMO

Alloplastic materials used for orbital fracture reconstruction can induce complications, such as infection, migration, extrusion, intraorbital hemorrhage, and residual diplopia. Silicone is one of the alloplastic materials that has been widely used for decades. The author reports a rare case of spontaneous extrusion of a silicone implant that was used for orbital fracture reconstruction 30 years earlier. A 50-year-old man was admitted to the emergency room for an exposed substance in the lower eyelid area of the left eye, which began as a palpable hard nodule a week earlier. The exposed material was considered to be implant used for previous surgery. Under general anesthesia, the implant and parts of the fibrous capsule tissue were removed. Several factors hinder the diagnosis of implant extrusions that occur a long period after the surgery. So, surgeons must be aware that complications with implants can still arise several decades following orbital fracture reconstruction, even without specific causes.


Assuntos
Humanos , Pessoa de Meia-Idade , Anestesia Geral , Diagnóstico , Diplopia , Serviço Hospitalar de Emergência , Pálpebras , Hemorragia , Órbita , Fraturas Orbitárias , Implantes Orbitários , Complicações Pós-Operatórias , Silício , Silicones , Cirurgiões
6.
Archives of Craniofacial Surgery ; : 137-140, 2017.
Artigo em Inglês | WPRIM | ID: wpr-131755

RESUMO

Alloplastic materials used for orbital fracture reconstruction can induce complications, such as infection, migration, extrusion, intraorbital hemorrhage, and residual diplopia. Silicone is one of the alloplastic materials that has been widely used for decades. The author reports a rare case of spontaneous extrusion of a silicone implant that was used for orbital fracture reconstruction 30 years earlier. A 50-year-old man was admitted to the emergency room for an exposed substance in the lower eyelid area of the left eye, which began as a palpable hard nodule a week earlier. The exposed material was considered to be implant used for previous surgery. Under general anesthesia, the implant and parts of the fibrous capsule tissue were removed. Several factors hinder the diagnosis of implant extrusions that occur a long period after the surgery. So, surgeons must be aware that complications with implants can still arise several decades following orbital fracture reconstruction, even without specific causes.


Assuntos
Humanos , Pessoa de Meia-Idade , Anestesia Geral , Diagnóstico , Diplopia , Serviço Hospitalar de Emergência , Pálpebras , Hemorragia , Órbita , Fraturas Orbitárias , Implantes Orbitários , Complicações Pós-Operatórias , Silício , Silicones , Cirurgiões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA