Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 554-556, 2007.
Artigo em Chinês | WPRIM | ID: wpr-238697

RESUMO

In order to explore the method to prepare hypoxia UW solution and the stability and preservation of hypoxia UW solution, UW solution was purged by argon or air for 15 min or 60 at a flow rate of 0.8 or 2 L/min, and the oxygen partial pressure of UW solution was detected. The hy-poxia UW solution was exposed to the air or sealed up to preserve by using different methods, and the changes of oxygen partial pressure was tested. The results showed that oxygen partial pressure of 50 mL UW solution, purged by argon for 15 min at a flow rate of 2 L/min, was declined from 242±6 mmHg to 83±10 mmHg. After exposure to the air, oxygen partial pressure of hypoxia UW solution was gradually increased to 160±7 mmHg at 48 h. After sealed up by the centrifuge tube and plastic bad filled with argon, oxygen partial pressure of hypoxia UW solution was stable, about 88±13 mmHg at 72 h. It was concluded that oxygen of UW solution could be purged by argon efficiently. Sealed up by the centrifuge tube and plastic bag filled with argon, oxygen partial pressure of UW so- lution could be stabilized.

2.
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 554-6, 2007.
Artigo em Inglês | WPRIM | ID: wpr-634986

RESUMO

In order to explore the method to prepare hypoxia UW solution and the stability and preservation of hypoxia UW solution, UW solution was purged by argon or air for 15 min or 60 at a flow rate of 0.8 or 2 L/min, and the oxygen partial pressure of UW solution was detected. The hypoxia UW solution was exposed to the air or sealed up to preserve by using different methods, and the changes of oxygen partial pressure was tested. The results showed that oxygen partial presure of 50 mL UW solution, purged by argon for 15 min at a flow rate of 2 L/min, was declined from 242+/-6 mmHg to 83+/-10 mmHg. After exposure to the air, oxygen partial pressure of hypoxia UW solution was gradually increased to 160+/-7 mmHg at 48 h. After sealed up by the centrifuge tube and plastic bad filled with argon, oxygen partial pressure of hypoxia UW solution was stable, about 88+/-13 mmHg at 72 h. It was concluded that oxygen of UW solution could be purged by argon efficiently. Sealed up by the centrifuge tube and plastic bag filled with argon, oxygen partial pressure of UW solution could be stabilized.


Assuntos
Adenosina/síntese química , Alopurinol/síntese química , Hipóxia , Glutationa/síntese química , Insulina/síntese química , Preservação de Órgãos/métodos , Soluções para Preservação de Órgãos/síntese química , Oxigênio/análise , Pressão Parcial , Rafinose/síntese química