1.
Southeast Asian J Trop Med Public Health ; 2004 Sep; 35(3): 552-9
Artigo em Inglês | IMSEAR | ID: sea-30721

RESUMO

A total of 453 clinical blood samples were determined for malaria parasites by flow cytometric assay (FCM) and reagents from Sysmex Corporation, Japan. In this study, the FCM greatly simplified and accelerated parasite detection, with sensitivity of 91.26%, specificity 86.28% and accuracy 87.42%. Overall, the parasite counts by flow cytometric measurement correlated well with the parasitemia measured by microscopic assay (regression coefficient = 0.9409). The detection limit was 0.05-0.1% parasitemia. No evidence of malaria parasites in either blood donor volunteers or other disease patients groups was determined by FCM. However, 48 samples who had been treated with antimalarial drugs and whose parasite microscopic counts were negative, showed false-positive results. When the data of these 48 samples were analyzed, they were found to have high levels of reticulocytes, ranging from 2.0-18.9%. This finding suggested that a high reticulocyte concentration in the blood may interfere with the performance of the FCM. Further improvement, by eliminating this interference, will make the FCM one of the most promising tests for malaria diagnosis.


Assuntos
Animais , Corantes Azur/diagnóstico , Contagem de Células Sanguíneas , Doadores de Sangue , Citometria de Fluxo/métodos , Humanos , Malária/diagnóstico , Microscopia/métodos , Parasitemia/diagnóstico , Plasmodium falciparum/isolamento & purificação , Plasmodium vivax/isolamento & purificação , Tailândia
2.
Southeast Asian J Trop Med Public Health ; 2004 Mar; 35(1): 35-7
Artigo em Inglês | IMSEAR | ID: sea-35599

RESUMO

In recent years, several rapid diagnostic tests for falciparum malaria have been developed. KAT test results were compared with microscopy on 90 consecutive patients hospitalized at the Hospital for Tropical Diseases, Bangkok, Thailand. Fifty-one patients had P. falciparum infections while 49 had malaria due to other plasmodium species. For a geometric mean +/-SD (Min;Max;range) parasitemia of 11,481 +/- 5.0 (88;713,838;713,750), the sensitivity of the KAT test was 96% (95% CI = 86-99.5), the specificity was 92% (95% CI = 80-99), the accuracy was 94% and the reliability was 85%. These findings suggest that the KAT test is of potential interest in the diagnosis of falciparum malaria in Thailand.


Assuntos
Animais , Anticorpos Antiprotozoários/análise , Intervalos de Confiança , Humanos , Malária Falciparum/diagnóstico , Microscopia/métodos , Plasmodium falciparum/isolamento & purificação , Proteínas de Protozoários/análise , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Testes Sorológicos/métodos , Tailândia
3.
Southeast Asian J Trop Med Public Health ; 2002 ; 33 Suppl 3(): 53-9
Artigo em Inglês | IMSEAR | ID: sea-35677

RESUMO

Two preparations of antigens for the diagnosis of strongyloidiasis were prepared from an extract of the infective larvae of Strongyloides stercoralis: a crude antigen (CA) and a molecular weight cut-off antigen (MWCOA). Both antigens were analysed by indirect ELISA against the sera of strongyloidiasis (26 cases), other helminthiases (167) and normal controls (30). The larvae were obtained from fecal culture by a modified polyethylene tube technique after screening tests by triple simple smears per case. The larvae were extracted with distilled water and further sonicated to obtain a supernatant, the CA. A part of the CA was separated for an antigen containing molecules of lower than 30 kDa by an ultrafree-MC centrifugal filter tube (PLTK): this was designed as the MWCOA. The CA gave 96.15% sensitivity and 40.12% (67/167) specificity at a cut-off value of 0.980 (5SD); false positives were produced by 19 of 20 different helminthiases. The MWCOA produced 96.15% sensitivity at cut-off value of 0.71 (4SD); the specificity of the test was 78.44% (131/167), higher than that of CA. False positives also appeared with 15 other helminthic infections. This study suggests that MWCOA is more specific than CA. A purified MWCOA will be necessary in order to reduce cross-reactivity and provide the suitable diagnosis of strongyloidiasis.


Assuntos
Animais , Antígenos de Helmintos/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoglobulina G/imunologia , Peso Molecular , Sensibilidade e Especificidade , Strongyloides stercoralis/imunologia , Estrongiloidíase/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA