Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Practical Nursing ; (36): 2634-2637, 2019.
Artigo em Chinês | WPRIM | ID: wpr-803562

RESUMO

Objective@#To investigate clinical application of self-designed organ traction bag in male genital immobilization during radiotherapy.@*Methods@#The male patients in the Department of Radiation Oncology, Suzhou Municipal Hospital from August 2018 to June 2019 were immobilized by using organ traction bag. Clinical effect was evaluated by subjective and objective ways which were the location relationship between contents and reference field under visual observation and fluoroscopy, and setup errors by CBCT images.@*Results@#A total of 11 patients were selected, including 3 seminoma, 2 low rectal carcinoma, 2 prostatic carcinoma, 4 pelvic lymph nodes and bone metastases, with mean age 57.18 years old. Patients received 273 times of treatment and 55 times of CBCT verifications in all. Analysis results that the setup errors of the whole group in upper and lower (Vrt), head and foot (Lng), left and right (Lat) directions are less than 0.5 cm, within acceptable clinical threshold. The contents under visual observation and fluoroscopy were not in reference field and were fixed well.@*Conclusions@#Organ traction bag provides stable effect on male genital immobilization while taking patients’ privacy and clinical operability into account. It has high clinical application value in radiotherapy involving male genital protection.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 686-689, 2017.
Artigo em Chinês | WPRIM | ID: wpr-662601

RESUMO

Objective To explore the effects of improvements on setup error ( SE ) and clinical target ( CTV ) margin of supraclavicular field ( SCF ) by using moisture-cured resin cushion and breast bracket for lower neck fixation in breast cancer patients who underwent post-mastectomy radiotherapy. Methods Totally 13 patients with breast cancer who underwent post-mastectomy radiotherapy were enrolled. All patients were immobilized by breast bracket and moisture-cured resin cushion. Firstly, each patient′s lower neck and head was fixed well by moisture-cured resin cushion, filling the gap between the neck and breast bracket. Secondly,each patient underwent the cone-beam CT ( CBCT) at the first, tenth and twentieth treatment after positioning. Then these CBCT images were registered to the planning CT to determine setup errors in translational and rotational directions, and SCF CTV margins by the systematic and random errors were evaluated. Results The setup errors in x (left-right), y (superior-inferior), z (anterior-posterior) translational directions were (2. 16 ± 1. 25), (1. 50 ± 1. 28), (1. 94 ± 1. 12) mm and (1. 76 ±1. 87)°, (1. 82 ±1. 12)°, (0. 99 ±0. 58)°, respectively in θ (pitch degree),Ф(roll degree),ψ( yaw degree) rotational directions. Non-parametric rank test ( Mann-Whitney U test) was performed with previous data, the differences of the setup error in y, z,θ directions were statistically significant ( Z =4. 152, 3. 415, 2. 053, P<0. 05). The margins from CTV were 4. 07, 4. 03 and 3. 73 mm in x, y and z directions, respectively. Compared with the previous study on SCF, CTV margin required 8, 8 and 6 mm in x, y and z axis directions, the volume of CTV to PTV were decreased by 32. 73% on average. Conclusions Compared with plastic circular pillow alone, moisture-cured resin cushion with breast bracket locating method could reduce setup errors in SCF target region. The margins from CTV to PTV weredecreased to 4. 07, 4. 03 and 3. 73 mm in x, y and z axis directions at least.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 686-689, 2017.
Artigo em Chinês | WPRIM | ID: wpr-660388

RESUMO

Objective To explore the effects of improvements on setup error ( SE ) and clinical target ( CTV ) margin of supraclavicular field ( SCF ) by using moisture-cured resin cushion and breast bracket for lower neck fixation in breast cancer patients who underwent post-mastectomy radiotherapy. Methods Totally 13 patients with breast cancer who underwent post-mastectomy radiotherapy were enrolled. All patients were immobilized by breast bracket and moisture-cured resin cushion. Firstly, each patient′s lower neck and head was fixed well by moisture-cured resin cushion, filling the gap between the neck and breast bracket. Secondly,each patient underwent the cone-beam CT ( CBCT) at the first, tenth and twentieth treatment after positioning. Then these CBCT images were registered to the planning CT to determine setup errors in translational and rotational directions, and SCF CTV margins by the systematic and random errors were evaluated. Results The setup errors in x (left-right), y (superior-inferior), z (anterior-posterior) translational directions were (2. 16 ± 1. 25), (1. 50 ± 1. 28), (1. 94 ± 1. 12) mm and (1. 76 ±1. 87)°, (1. 82 ±1. 12)°, (0. 99 ±0. 58)°, respectively in θ (pitch degree),Ф(roll degree),ψ( yaw degree) rotational directions. Non-parametric rank test ( Mann-Whitney U test) was performed with previous data, the differences of the setup error in y, z,θ directions were statistically significant ( Z =4. 152, 3. 415, 2. 053, P<0. 05). The margins from CTV were 4. 07, 4. 03 and 3. 73 mm in x, y and z directions, respectively. Compared with the previous study on SCF, CTV margin required 8, 8 and 6 mm in x, y and z axis directions, the volume of CTV to PTV were decreased by 32. 73% on average. Conclusions Compared with plastic circular pillow alone, moisture-cured resin cushion with breast bracket locating method could reduce setup errors in SCF target region. The margins from CTV to PTV weredecreased to 4. 07, 4. 03 and 3. 73 mm in x, y and z axis directions at least.

4.
Chinese Journal of Radiological Medicine and Protection ; (12): 753-756, 2016.
Artigo em Chinês | WPRIM | ID: wpr-502319

RESUMO

Objective To evaluate the setup errors for lower neck with cone beam CT (CBCT) in breast cancer patients immobilized by breast bracket,and to probe the margins from supraclavicular clinical target volume (CTV) in 3 directions.Methods A total of 14 breast cancer patients with supraclavicular lymph node radiation were enrolled.All patients were immobilized by breast bracket,and each patient would undergo CBCT at the first,tenth and twentieth treatment after positioning,respectively.Then these CBCT images were registered to the planning CT to determine setup errors in translational and rotational direction,and evaluated correlation between them.At last,CTV margins were calculated from the systenatic and random errors.Results The setup errors on x (left-ring),y (superior-inferior),z (anterior-posterior) translational directions were (2.89 ±.2.52),(3.96 ±2.97),(4.21 ±2.24) mm and on θ (pitch degree),φ (roll degree),Ψ (yaw degree) rotational direction were (2.38 ± 1.97)°,(1.60±1.63) °,(1.91 ±1.54)°,respectively.The margins from CTV were 8.08,8.13,6.30mminx,y and z direction.On y and z directions translational errors were correlated significantly with φ and Ψ degree rotational errors(Pearson =-0.515,-0.509,P < 0.05).In inter-fraction only on z direction the setup changes were considered as correlative with Ψ degree (Pearson =-0.583,P < 0.05).Conclusions For supraclavicular region irradiation breast cancer patients immobilized with breast bracket,the margins from CTV were recommended as not less than 8.08,8.13,6.30 mm in x,y,z directions,respectively.The position immobilized method and the positioning workflow should be further improved in order to reduce the influence of the neck rotational on setup errors.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA