Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Information on Traditional Chinese Medicine ; (12): 84-86, 2017.
Artigo em Chinês | WPRIM | ID: wpr-614177

RESUMO

Objective To establish a method for determination of phenylethanoid glycoside and acteoside in Plantago Herba. Methods UV-visible spectrophotometric method was used for the determination of the content of phenylethanoid glycosides compounds in Plantago Herba. HPLC method was used for the determination of acteoside in Plantago Herba. Chromatographic column with C18 ODS2 (4.6 mm × 150 mm, 5 μm) was used. Acetonitrile-0.1%formic acid (13:87) was as mobile phase; the flow rate was 1 mL/min; the detection wavelength was 332 nm; the column temperature was 30 ℃; the sample volume was 10 μL. Results The contents of phenylethanoid glycoside in Plantago Herba from different producing areas were among 1.03%–3.47%. Acteoside with peak area over the 0.0062–1.55 mg range showed a good linear relationship; the sample recovery rate was 98.9%, and the RSD was 1.6%. The contents of acteoside in Plantago Herba from different producing areas was among 0.18%–0.56%. Conclusion The method is simple, stable and reproducible, which can be used for the determination of phenylethanoid glycoside and acteoside in Plantago Herba from different producing areas and provide experimental basis for quality control of Plantago Herba.

2.
China Pharmacist ; (12): 184-186, 2017.
Artigo em Chinês | WPRIM | ID: wpr-508096

RESUMO

Objective:To study the compatibility and stability of coenzyme A for injection, adenosine disodium triphosphate and inosine injection. Methods:By simulating the clinical medication, the three drugs and 5% glucose injection were mixed together. The contents and relative substances of coenzyme A, adenosine disodium triphosphate and inosine were measured by HPLC. The changes in appearance, pH and insoluble particles were observed or tested at ambient temperature. Results:The mixed solution showed no signifi-cant changes in appearance, pH, number of insoluble particles, contents and relative substances of coenzyme A, adenosine disodium triphosphate and inosine in 4 h, while the mixed solution became turbid and the pH, number of insoluble particles and contents of the three drugs showed significant changes after 24-h storage. Conclusion:The mixed solution of coenzyme A for injection, adenosine dis-odium triphosphate and inosine injection in 5% glucose injection should be used up in 4 h at ambient temperature.

3.
China Pharmacist ; (12): 1477-1479, 2017.
Artigo em Chinês | WPRIM | ID: wpr-611413

RESUMO

Objective: To determine total phenylethanoid glycoside and acteoside in Plantago Herba to provide reference for evaluating the quality of medicinal materials.Methods: With acteoside as the control sample, a UV visible spectrophotometric method was used to determine total phenylethanoid glycosides in Plantago Herba.An HPLC method was applied to determine acteoside in Plantago Herba , and the conditions were as follows: an ODS2 C 18 (150 mm× 4.6 mm ,5 μm) chromatographic column was used with acetonitrile-0.1% formic acid (13∶87) as the mobile phase at a flow rate of 1.0 ml·min-1 , the detection wavelength was 332nm, the column temperature was 30℃, and the sample volume was 10 μl.Results: The reference solution and the sample solution had the maximum absorption at 332 nm, and the linear relationship was good within the range of 0.003 1-0.155 0 mg·ml-1 (r=0.999 5).The content of total benzene alcohol glycosides in 3 batches of samples was 2.73% , 2.61% and 2.84% , respectively;acteoside over the range of 0.000 6-0.155 0 mg·ml-1 (r=0.999 1) showed a good linear relationship with peak area,the sample recovery was 98.5% and the RSD was 1.6% (n =6), and the acteoside content in 3 batches of samples respectively was 0.54% , 0.51% and 0.56%.Conclusion: The method is simple, accurate and reproducible, and can be used for the determination of total phenylethanoid glycosides and acteoside in Plantago Herba.

4.
China Pharmacy ; (12): 2558-2559, 2016.
Artigo em Chinês | WPRIM | ID: wpr-504669

RESUMO

OBJECTIVE:To establish a method for the content determination of kaempferol in Kaempferia galanga. METH-ODS:HPLC was performed on the column of Diamonsil ODS2 C18 with mobile phase of methanol-0.4% Phosphoric acid solution at a flow rate of 1 ml/min,detection wavelength was 367 nm,column temperature was 30℃,and injection volume was 10 μl. RE-SULTS:The linear range of kaempferol was 0.001 58-0.158 mg/ml;RSDs of precision,stability and reproducibility tests were low-er than 3%;recovery was 95.52%-99.32%(RSD=1.47%,n=6). CONCLUSIONS:The method is simple,accurate and reproduc-ible,and can be used for the content determination of kaempferol in K. galanga.

5.
China Pharmacist ; (12): 390-391,392, 2016.
Artigo em Chinês | WPRIM | ID: wpr-603455

RESUMO

Objective: To establish an HPLC method for the determination of coenzyme A in coenzyme complex for injection. Methods:The content determination was performed on an Intersil ODS-3 column with methanol-pH 6. 5 phosphate buffer solution (10∶90) as the mobile phase. The detection wavelength was 259 nm and the flow rate was 1. 0 ml·min-1 . The column temperature was 30℃ and the injection volume was 20 μl. Results:The linear range of coenzyme A was 1.624-32.482 u·ml-1(r=0.999 9). The average recovery was 102. 36% and RSD was 1. 14%(n=6). Conclusion: The method is simple, accurate and reproducible, and it can be used for the quality control of coenzyme complex for injection.

6.
Chinese Journal of Information on Traditional Chinese Medicine ; (12): 82-86, 2016.
Artigo em Chinês | WPRIM | ID: wpr-498435

RESUMO

Objective To optimize the prescription of GA and GB hydrophilic gel matrix tablets; To study the in vitro release mechanism. Methods On the basis of the results of the mono-factor investigation, mixture uniform design was used to optimize the handicraft molding prescription of GA and GB hydrophilic gel matrix tablets. The release mechanism was investigated by the vitro of the GA and GB hydrophilic gelmatrix tablets to accumulate releasing rate to conduct linear fitting. Results The optimized prescription of GA and GB hydrophilic gel matrix tablets was: powder: HPMC: lactose=23:24:53. Conclusion Mixture uniform design can be used to optimize the prescriptions of GA and GB hydrophilic gel matrix tablets, and the results are accurate. The hydrophilic gelmatrix tablets release medicine by non-Fick mechanism, and the medicine release is in accordance with zero-order.

7.
Chinese Journal of Information on Traditional Chinese Medicine ; (12): 77-79, 2016.
Artigo em Chinês | WPRIM | ID: wpr-489908

RESUMO

Objective To establish an HPLC method for the simultaneous determination of quercetin and kaempferol inKaempferia galanga L..Methods ODS2 C18 (5μm, 4.6 mm×150 mm) was used as chromatographic column; methanol-0.4% phosphate (47:53) was the mobile phase; the flow rate was 1 mL/min; column temperature was 30℃; the detection wavelength was 367 nm; the injection volume was 10μL.Results Quercetin showed good linear relationship in the range of 0.016 5–1.65μg (r=0.999 7). The average recovery rate was 96.8%, RSD=2.02%; kaempferol showed good linear relationship in the range of 0.014 6–1.46μg (r=0.999 5). The average recovery rate was 97.3%, RSD=1.77%.Conclusion The method is simple, accurate, and with good reproducibility, which can be used for content determination of quercetin and kaempferol inKaempferia galanga L..

8.
Herald of Medicine ; (12): 526-529, 2016.
Artigo em Chinês | WPRIM | ID: wpr-486449

RESUMO

Objective To study the compatible stability of the carbohydrate-electrolyte injection and commonly used vitamin-electrolyte injections. Methods By simulating clinical use of medicines,the carbohydrate-electrolyte injection and various vitamin-electrolyte injections were mixed respectively.The content of sodium acetate was measured by HPLC,and changes in appearance,pH value and insoluble particles of the injections were observed. Results At room temperature,the compatibility solutions showed no significant changes in appearance,pH value,the number of insoluble particles and the content of sodium acetate within 8 h. Conclusion The carbohydrate-electrolyte injection is compatible with commonly used vitamin-electrolyte injections,and the admixtures are stable within 8 h at room temperature.

9.
Acta Pharmaceutica Sinica ; (12): 1144-9, 2011.
Artigo em Chinês | WPRIM | ID: wpr-414986

RESUMO

The free membrane of Eudragit L100/S100 which is pH-sensitive, colon-specific was prepared by plane casting films. The film humidity, species and amount of plasticizers, the ratio of membrane material was investigated. The rate of membrane permeability and mechanical properties were used as indicators of orthogonal experiment, and its related properties were studied. The results show that the mechanical properties of the membrane and phragmoid capacity are the best when 30% TEC was used as plasticizer; the ratio of membrane material have little effect on the rate of membrane permeability and mechanical properties. By adjusting the species and amount of plasticizers, the ratio of Eudragit L100/S100, the free membrane which is colon-specific can be obtained.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA