Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Journal of Peking University(Health Sciences) ; (6): 94-100, 2023.
Artigo em Chinês | WPRIM | ID: wpr-971279

RESUMO

OBJECTIVE@#To study microstructure, friction and wear behaviors of silicon-lithium spray coating on the surface of zirconia ceramics and to preliminarily evaluate its esthetic so as to provide support and guidance for the clinical application.@*METHODS@#Zirconia ceramic specimens were randomly divided into three groups: coating group (two subgroups), polishing group (two subgroups), and glazing group (four subgroups), with 10 samples in each subgroup. The two subgroups of coating group were the zirconia ceramics with the untreated and preliminary polishing surfaces sprayed with silicon-lithium coating, respectively. The two subgroups of polishing group were preliminary polishing and fine polishing of zirconia ceramics, respectively. The four subgroups of glazing group were preliminarily polished zirconia ceramics glazed with Biomic and Stain/Glaze products, respectively; and untreated zirconia ceramics glazed with Biomic and Stain/Glaze products, respectively. The above 8 subgroups of zirconia ceramic specimens were used as friction pairs with 80 steatite ceramics for 50 000 chewing cycles under 50 N vertical load and artificial saliva lubrication using chewing simulation. Scanning electron microscope was used to observe the microstructure of the surface and section of the coating group, and the thickness of the coating and glazing were measured. The linear roughness of the coating and polishing groups was mea-sured using a laser confocal scanning microscope. Vickers hardness was measured using a microhardness tester and the esthetic of zirconia ceramic full crown sprayed with silicon-lithium coating was preliminarily evaluated. White light interferometer was used to measure the width, the maximum depth and the volume of the wear scars of each group, and the wear depth of steatite ceramics and wear rate of zirconia ceramic specimens were calculated. Kruskal-Wallis nonparametric test and Dunn's multiple comparisons test were used to analyze the wear depth of each group (α=0.05).@*RESULTS@#The microstructures of the silica-lithium spray coatings on the untreated and preliminarily polished zirconia ceramic surfaces showed the protruding defects, and the line roughness of coating group was larger than that of the polishing group. The median thickness of the silica-lithium spray coating on the preliminarily polished zirconia ceramic was 13.0 μm (interquartile range, IQR: 11.6, 17.9), while that of the silica-lithium spray coating on the untreated zirconia ceramic was 4.4 μm (IQR: 4.1, 4.7). The Vickers hardness and wear rate of the coating group were between the polishing group and the glazing group. The wear depths of the wear scars of steatite ceramics were the glazing group, coating group, and polishing group in descending order, and there was statistically significant difference between glazing and polishing groups (P < 0.05). With the increase of polishing procedure, the wear depth of steatite ceramics decreased in each subgroups. The orders of maximum depth and volume of wear scars of zirconia ceramic were the glazing group, coating group, and polishing group in descending order, and there was statistically significant difference in the maximum depth of wear scars between glazing and polishing groups (P < 0.05).@*CONCLUSION@#The silica-lithium spray coating on the zirconia ceramic, can be used as a new method for zirconia ceramic surface treatment, because it can increase the esthetic of zirconia ceramics compared with polishing and reduce the wear of steatite ceramics compared with glazing.


Assuntos
Humanos , Silício , Teste de Materiais , Fricção , Lítio , Cicatriz , Propriedades de Superfície , Dióxido de Silício , Zircônio/química , Cerâmica , Porcelana Dentária
2.
Chinese Journal of Otorhinolaryngology Head and Neck Surgery ; (12): 505-509, 2022.
Artigo em Chinês | WPRIM | ID: wpr-936246

RESUMO

Objective: To assess the incidence of symptomatic torus tubarius hypertrophy (TTH) in recurred OSA in children, and to explore the preliminary experience of partial resection of TTH assisted with radiofrequency ablation. Methods: From January 2004 to February 2020, 4 922 children, who diagnosed as OSA and received adenotonsillectomy at the Department of Otolaryngology, The 4th Medical Center of the PLA General Hospital, were retrospectively reviewed. There were 3 266 males and 1 656 females, the age ranged from 1 to 14 years old(median age of 5.0 years). Twenty-two cases were identified with recurrence of OSA syndrome, and the clinical data, including sex, age of primary operation, age of recurrence and presentation, and opertation methods were analyzed. Follow-up was carried out by outpatient visit or telephone. Graphpad prism 5.0 software was used for statistical analysis. Results: Twenty-two cases were identified as recurred OSA and received revised surgery in 4 922 cases. Among these 22 cases, 11 cases were diagnosed as TTH resulting in an incidence of 2.23‰(11/4 922), 1 case was cicatricial adhesion on tubal torus (0.20‰, 1/4 922), 10 cases were residual adenoid combined with tubal tonsil hypertrophy (2.03‰, 10/4 922). Median age of primary operation was 3.0 years (range:2.4 to 6.0 years) in 11 TTH cases. Recurrent interval varied from 2 months to 5.5 years (2.4±1.9 years) after first operation. Age of revised partial resection of TTH was 7.0±2.7 years (range: 4.0 to 12.0 years). Average time interval between primary operation and revised operation was 3.5±2.1 years (range: 0.5 to 6.0 years). Individualized treatments were carried out based on partial resection of TTH assisted with radiofrequency ablation. All of 11 cases received satisfied therapeutic results without nasopharyngeal stenosis occured. Twenty-two cases were followed up for 1.6 to 13 years (median follow-up time was 6.2 years). Conclusions: TTH contributed to recurred OSA in child. TTH might be misdiagnosed as tubal tonsil hypertrophy. Partial resection of TTH assisted with radiofrequency ablation was a safty and effective treatment.


Assuntos
Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Adenoidectomia , Tonsila Faríngea/cirurgia , Hipertrofia/cirurgia , Estudos Retrospectivos , Apneia Obstrutiva do Sono/cirurgia
3.
Journal of Peking University(Health Sciences) ; (6): 105-112, 2022.
Artigo em Chinês | WPRIM | ID: wpr-936120

RESUMO

OBJECTIVE@#To compare the retentions of different designs of cobalt-chromium (Co-Cr), pure titanium (CP Ti), and titanium alloy (Ti-6Al-4V) removable partial denture (RPD) circumferential clasps manufactured by selective laser melting (SLM) and to analyze the stress distribution of these clasps during the removal from abutment teeth.@*METHODS@#Clasps with clasp arm size A (1.9 mm width/1.1 mm thickness at the body and 0.8-taper) or B (1.2 times A) and 0.25 mm or 0.50 mm undercut engagement were modeled on a prepared first premolar die, named as designs A1, A2, A3, and A4, respectively. The density and elastic modulus of SLM-built Co-Cr, CP Ti, and Ti-6Al-4V were measured and given to different groups of clasps. The density, elastic modulus, and Poisson ' s ratio of enamel were given to the die. The control group was the cast Co-Cr clasp with design A1, to which the density and elastic modulus of cast Co-Cr alloy were given. The Poisson's ratio of all metals was 0.33. The initial 5 N dislodging force was applied, and the maximum displacement of the clasp along the insertion path was computed. The load was reapplied with an increment of 5 N than in the last simulation until the clasp was completely dislodged. The retentive force range of different groups of clasps was obtained. The retentive forces of the SLM-built Co-Cr, CP Ti, and Ti-6Al-4V clasps with equivalent computed retentive force range to the control group were validated through the insertion/removal experiment. The von Mises stress distributions of these three groups of SLM-built clasps under 15 N loads were analyzed.@*RESULTS@#SLM-built Co-Cr, CP Ti, and Ti-6Al-4V clasps with designs B1 or B2, and Co-Cr clasps with design A2 had higher retentive forces than those of the control group. SLM-built CP Ti and Ti-6Al-4V clasps with design A1 had lower retentive forces than those of the control group. SLM-built Co-Cr clasp with design A1 and SLM-built CP Ti and Ti-6Al-4V clasps with design A2 had equivalent retentive forces to those of the control group. The insertion/removal experiment showed that the measured retentive forces of these three groups of SLM-built clasps were (21.57±5.41) N, (19.75±4.47) N, and (19.32±2.04) N, respectively. No statistically significant measured retentive force difference was found among these three groups of SLM-built clasps (P>0.05). The maximum von Mises stress of these three groups of SLM-built clasps exceeded their responding yield strength except for the Ti-6Al-4V one.@*CONCLUSION@#SLM-built Co-Cr circumferential clasps had higher retention than CP Ti and Ti-6Al-4V ones with the same clasp arm size and undercut engagement. The retention of SLM-built circumferential clasps could be adjusted by changing the undercut engagement and clasp arm size. If SLM-built circumferential clasps are used in clinical practice, the Ti-6Al-4V clasp with clasp arm size A and 0.50 mm undercut engagement is recommended considering the long-term use of RPD in the patient's mouth.


Assuntos
Humanos , Ligas de Cromo , Grampos Dentários , Retenção de Dentadura , Prótese Parcial Removível , Análise de Elementos Finitos , Lasers , Titânio
4.
Journal of Peking University(Health Sciences) ; (6): 31-39, 2022.
Artigo em Chinês | WPRIM | ID: wpr-936109

RESUMO

OBJECTIVE@#To investigate the effect of porous surface morphology of zirconia on the proliferation and differentiation of osteoblasts.@*METHODS@#According to different manufacturing and pore-forming methods, the zirconia specimens were divided into 4 groups, including milled sintering group (M-Ctrl), milled porous group (M-Porous), 3D printed sintering group (3D-Ctrl) and 3D printed porous group (3D-Porous). The surface micromorphology, surface roughness, contact angle and surface elements of specimens in each group were detected by scanning electron microscope (SEM), 3D laser microscope, contact angle measuring device and energy-dispersion X-ray analysis, respectively. MC3T3-E1 cells were cultured on 4 groups of zirconia discs. The cell morphology of MC3T3-E1 cells on zirconia discs was eva-luated on 1 and 7 days by SEM. The cell proliferation was detected on 1, 3 and 5 days by cell counting kit-8 (CCK-8). After osteogenic induction for 14 days, the relative mRNA expression of alkaline phosphatase (ALP), type Ⅰ collagen (Colla1), Runt-related transcription factor-2 (Runx2) and osteocalcin (OCN) in MC3T3-E1 cells were detected by real-time quantitative polymerase chain reaction.@*RESULTS@#The pore size [(419.72±6.99) μm] and pore depth [(560.38±8.55) μm] of 3D-Porous group were significantly larger than the pore size [(300.55±155.65) μm] and pore depth [(69.97±31.38) μm] of M-Porous group (P < 0.05). The surface of 3D-Porous group appeared with more regular round pores than that of M-Porous group. The contact angles of all the groups were less than 90°. The contact angles of 3D-Ctrl (73.83°±5.34°) and M-Porous group (72.7°±2.72°) were the largest, with no significant difference between them (P>0.05). Cells adhered inside the pores in M-Porous and 3D-Porous groups, and the proliferation activities of them were significantly higher than those of M-Ctrl and 3D-Ctrl groups after 3 and 5 days' culture (P < 0.05). After 14 days' incubation, ALP, Colla1, Runx2 and OCN mRNA expression in 3D-Porous groups were significantly lower than those of M-Ctrl and 3D-Ctrl groups (P < 0.05). Colla1, Runx2 and OCN mRNA expressions in M-Porous group were higher than those of 3D-Porous group (P < 0.05).@*CONCLUSION@#The porous surface morphology of zirconia can promote the proliferation and adhesion but inhibit the differentiation of MC3T3-E1 cells.


Assuntos
Diferenciação Celular , Proliferação de Células , Cerâmica , Osteoblastos , Osteogênese , Porosidade , Zircônio
5.
Journal of Peking University(Health Sciences) ; (6): 7-12, 2022.
Artigo em Chinês | WPRIM | ID: wpr-936105

RESUMO

According to the fourth national oral health epidemiological survey report (2018), billions of teeth are lost or missing in China, inducing chewing dysfunction, which is necessary to build physiological function using restorations. Digital technology improves the efficiency and accuracy of oral restoration, with the application of three-dimensional scans, computer-aided design (CAD), computer-aided manufacturing (CAM), bionic material design and so on. However, the basic research and product development of digital technology in China lack international competitiveness, with related products basically relying on imports, including denture 3D design software, 3D oral printers, and digitally processed materials. To overcome these difficulties, from 2001, Yuchun Sun's team, from Peking University School and Hospital of Stomatology, developed a series of studies in artificial intelligence design and precision bionics manufacturing of complex oral prostheses. The research included artificial intelligence design technology for complex oral prostheses, 3D printing systems for oral medicine, biomimetic laminated zirconia materials and innovative application of digital prosthetics in clinical practice. The research from 2001 to 2007 was completed under the guidance of Prof. Peijun Lv and Prof. Yong Wang. Under the support of the National Natural Science Foundation of China, the National Science and Technology Support Program, National High-Tech R & D Program (863 Program) and Beijing Training Project for the Leading Talents in S & T, Yuchun Sun's team published over 200 papers in the relevant field, authorized 49 national invention patents and 1 U.S. invention patent and issued 2 national standards. It also developed 8 kinds of core technology products in digital oral prostheses and 3 kinds of clinical diagnosis and treatment programs, which significantly improved the design efficiency of complex oral prostheses, the fabrication accuracy of metal prostheses and the bionic performance of ceramic materials. Compared with similar international technologies, the program doubled the efficiency of bionic design and manufacturing accuracy and reduced the difficulty of diagnosis and cost of treatment and application by 50%, with the key indicators of those products reaching the international leading level. This program not only helped to realize precision, intelligence and efficiency during prostheses but also provided functional and aesthetic matches for patients after prostheses. The program was rewarded with the First Technical Innovation Prize of the Beijing Science and Technology Awards (2020), Gold Medal of Medical Research Group in the First Medical Science and Technology Innovation Competition of National Health Commission of the People's Republic of China (2020) and Best Creative Award in the First Translational Medical Innovation Competition of Capital (2017). This paper is a review of the current situation of artificial intelligence design and precision bionics manufacturing of complex oral prosthesis.


Assuntos
Humanos , Inteligência Artificial , Biônica , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Impressão Tridimensional , Próteses e Implantes
6.
Chinese Journal of Stomatology ; (12): 540-546, 2022.
Artigo em Chinês | WPRIM | ID: wpr-935899

RESUMO

With the advent of the era of big data, artificial intelligence based on machine learning, especially artificial neural network has rapidly developed and applicated in the field of stomatology, owning huge potential in segmentation and labelling of three-dimensional intraoral anatomical features. Automatic segmentation, labelling and diagnosis can assist dentists and technicians to complete heavy and repeat work, change stomatology from subjective perception to objective science, and help to make diagnosis and treatment plan efficiently and accurately. This review briefly summarized related knowledge and development of machine learning and artificial neural network, its application status and existing problems in the field of segmentation and labelling of three-dimensional intraoral anatomical features, and provided an outlook of its future development.


Assuntos
Inteligência Artificial , Aprendizado de Máquina , Redes Neurais de Computação
7.
Chinese Journal of Stomatology ; (12): 162-167, 2022.
Artigo em Chinês | WPRIM | ID: wpr-935843

RESUMO

Objective: To evaluate the effect of adding a geometric feature on the accuracy of digital impressions obtained by intraoral scanners for implant restoration of edentulous jaw quantitatively. Methods: A dentiform model of the maxilla of completely edentulous arch with 6 implant analogs+scan bodies (No. 1-6) was selected as the reference model. Without geometric feature, the dentiform model was scanned by dental model scanner and repeated for 5 times as true value group. Before and after adding the geometric feature, the same operator used intraoral scanner A (Trios 3) and B (Aoralscan 2) to scan the dentiform model with the same scanning path. Each type of intraoral scanner scanned 10 times and ".stl " datas were obtained. The results were imported into reverse engineering software (Geomagic Studio 2015). The linear distances of center point of upper plane between sacn body 1 to 6 was calculated, denoted as D12, D13, D14, D15 and D16. Trueness was the absolute value subtracted from the measured value of the intraoral scanner groups and true value; precision was the absolute value of pairwise subtraction of the measured values in the intraoral scanner groups.The smaller the value, the better the accuracy or precision.With or without the feature, all scan data were statistically analyzed, and the effect of adding geometric feature on the trueness and precision of the two intraoral scanners were evaluated. Results: As for intraoral scanner A, with the feature in place, significant differences were found in D14, D15, D16 for tureness(t=2.66, 2.75, 2.95, P<0.05); the trueness for D16 decreased from (101.9±47.1) μm to (49.6±30.3) μm. On the other hand, with features on the edentulous area, the precision was significantly increased in D15 and D16 (U=378.00, 672.00, P<0.05); the precision for D15 decreased from 40.8 (45.1) μm to 13.1 (17.0) μm. As for intraoral scanner B, the trueness of D12, D13 and D14 after adding geometric features was significantly better than before (t=3.02, 2.66, U=22.00, P<0.05). With feature on the edentulous area, the trueness for D13 decreased from (116.6±41.2) μm to (70.8±35.5) μm. There was no statistical significance in the trueness of D15 and D16 with or without geometric feature (P>0.05), however, the precision of D15 and D16 after adding geometric feature was significantly better than before (U=702.00, 489.00,P<0.05). The precision of D16 decreased from 112.5 (124.7) μm to 35.9 (85.8) μm. Conclusions: The use of geometric feature in edentulous space improves the trueness and precision of the different principle intraoral scanners tested.


Assuntos
Desenho Assistido por Computador , Implantes Dentários , Técnica de Moldagem Odontológica , Imageamento Tridimensional , Modelos Dentários
8.
Chinese Journal of Stomatology ; (12): 101-106, 2022.
Artigo em Chinês | WPRIM | ID: wpr-935836

RESUMO

In dental esthetic rehabilitation, patients pay great attention to the rehabilitative esthetic effect before teeth preparation, and this is also an important content of doctor-patient communication. Along with the development and combined application of intraoral scan, three-dimensional (3D) face scan, digital design, numerical control machining and 3D printing technology, digital technology is gradually applied to the virtual simulated design before irreversible operation in dental esthetic rehabilitation. Digital technology can be used in dentistry to simulate the esthetic outcome in advance, to assist communication among the dentists, patients and dental technicians, and to realize satisfactory outcome in the final restorations precisely, which, as a result, increases the clinical satisfaction. This review focuses on the application of digital virtual simulated design technology in dental esthetic rehabilitation, analyzes the current research development, deficiency and future prospects, so as to provide guidance for clinical diagnosis and treatment.


Assuntos
Humanos , Desenho Assistido por Computador , Estética Dentária , Face , Impressão Tridimensional , Preparo do Dente
9.
Chinese Journal of Hospital Administration ; (12): 920-926, 2022.
Artigo em Chinês | WPRIM | ID: wpr-996017

RESUMO

Objective:To summarize the strategies, influencing factors and evaluation methods of foreign stroke service system integration, so as to provide reference for the construction of integrated stroke service system in China.Methods:The scoping review method was used to search, screen and analyze the literature. Using search terms such as stroke and integration, a total of 7 527 articles from PubMed and other databases from 2000 to 2021 were obtained. The strategies, influencing factors, evaluation methods and results of stroke service system integration were extracted from the literature. The rainbow model of health integration was used to establish the literature analysis framework.Results:A total of 103 articles involved system integration strategies were included in the analysis, 49 articles involved integration influencing factors, and 32 articles involved integration evaluation. Stroke service system integration strategies included 3 categories and 13 forms, including service coverage, normative shaping and information technology integration. The influencing factors of integration included local stroke service resources, implementation ability, social development level and institutional environment. System integration evaluation included systematic evaluation and case evaluation.Conclusions:The goal of stroke service system integration is to improve the coverage, quality and efficiency of stroke services. The internal drive comes from market and technology. The three types of integration strategies have their own emphasis and are integrated with each other. They are deeply embedded in the regional resource, institutional and cultural environment. Their evaluation is facing the challenge of high situational and low universality.

10.
Journal of Integrative Medicine ; (12): 469-477, 2021.
Artigo em Inglês | WPRIM | ID: wpr-922522

RESUMO

Hepatocellular carcinoma (HCC) is one of the most prevalent malignant cancers worldwide. Epithelial-mesenchymal transition (EMT), which endows epithelial cells with mesenchymal properties, plays an important role in the early stages of metastasis. Conventional cancer therapies have promising effects, but issues remain, such as high rates of metastasis and drug resistance. Thus, exploring and evaluating new therapies is an urgent need. Traditional Chinese medicines (TCMs) have been acknowledged for their multi-target and coordinated intervention effects against HCC. Accumulating evidence indicates that TCM can inhibit the malignancy of cells and the progression of EMT in HCC. However, studies on the effects of TCM on EMT in HCC are scarce. In this review, we summarized recent developments in anti-EMT TCMs and formulae, focusing on their underlying pharmacological mechanisms, to provide a foundation for further research on the exact mechanisms through which TCM affects EMT in HCC.


Assuntos
Humanos , Carcinoma Hepatocelular/tratamento farmacológico , Transição Epitelial-Mesenquimal , Neoplasias Hepáticas/tratamento farmacológico , Medicina Tradicional Chinesa
11.
West China Journal of Stomatology ; (6): 1-8, 2021.
Artigo em Inglês | WPRIM | ID: wpr-878402

RESUMO

Digital technologies use high-precision three-dimensional scanning, intelligence-aided design software, and multi-axis numerical control milling or 3D printing, which can produce restorations with reliable precision and suitable function. However, the development of digital technologies in the field of complete denture restoration has been slow due to the complexity of prosthesis. This review article introduces the current research status and clinical applications of digital complete dentures in prosthodontic clinics and dental laboratories to provide beneficial references to prosthodontists and dental technicians.


Assuntos
Desenho Assistido por Computador , Prótese Total , Impressão Tridimensional
12.
Journal of Peking University(Health Sciences) ; (6): 406-412, 2021.
Artigo em Chinês | WPRIM | ID: wpr-942195

RESUMO

OBJECTIVE@#To compare the differences and indications of three evaluation methods for fitness evaluation of removable partial denture (RPD).@*METHODS@#A RPD was fabricated and seated on the stone cast of a partially edentulous mandible, and the spaces between RPD and stone cast were recorded with polyvinyl siloxane (PVS) impression material forming PVS replicas. Using cross sectional measurement, the average thicknesses of PVS replicas were measured under stereomicroscope with different numbers of selected measuring points in the denture base, major connector, occlusal rest of the RPD, and the average thicknesses of the PVS replicas measured with different numbers of measuring points were compared using one-way analysis of variance (ANOVA) and independent sample t test. Three kinds of method, including cross sectional measurement, three-dimensional analysis on the stone cast, and three-dimensional analysis on the polyether cast, were applied to measure the average thicknesses of the PVS replicas, and the average thicknesses of the PVS replicas measured by these three evaluation methods were compared with ANOVA.@*RESULTS@#For cross sectional measurement, statistically significant differences were found in the average thicknesses of the PVS replicas in the denture base and the major connector among the different numbers of measuring points (P < 0.05), but no differences were found in the average thicknesses of the PVS replicas in the occlusal rest (P>0.05). There were significant differences among the average thicknesses of the PVS replicas measured by these three evaluation methods in each component of the RPD (P < 0.01). The average thickness measured by three-dimensional analysis on the stone cast and three-dimensional analysis on polyether cast were smaller than that measured by cross sectional measurement (P < 0.05). And there were no differences between the average thicknesses of PVS replicas measured by three-dimensional analysis on stone cast and three-dimensional analysis on polyether cast (P>0.05).@*CONCLUSION@#For cross sectional measurement, the average thickness of the PVS replicas was influenced by the number of measuring points, and the measurement accuracy of cross sectional measurement was not reliable enough. Three-dimensional analysis on stone cast which is suitable for evaluation in vitro and three-dimensional analysis on polyether cast which is suitable for evaluation in vivo can evaluate the fitness of RPD more comprehensively and effectively than that of cross sectional measurement.


Assuntos
Desenho Assistido por Computador , Estudos Transversais , Prótese Parcial Removível , Exercício Físico , Projetos de Pesquisa
13.
Journal of Peking University(Health Sciences) ; (6): 402-405, 2021.
Artigo em Chinês | WPRIM | ID: wpr-942194

RESUMO

OBJECTIVE@#To evaluate the effects of different edge compensation angles on the fracture strength of multilayer zirconia all-ceramic crowns and traditional uniform zirconia all-ceramic crowns.@*METHODS@#The resin tooth preparation specimen of the mandibular first molar with a knife-edge was fabricated. A 3D digital model of the specimen was obtained by scanning it with a 3D dental model scanner. The 3D digital model was imported into computer aided design (CAD) software, and three 3D digital models of the full crown with the same surface shape are designed with the edge compensation angles of 30°, 45° and 60°, respectively. Then, the designed 3D digital model is imported into computer aided manufacturing (CAM) software. Three kinds of multilayer and homogeneous zirconia all-porcelain crowns with different edge compensation angles were fabricated, 10 each for a total of 60. The fracture load of each crown was measured under the electronic universal testing machine.@*RESULTS@#Fracture load of multilayer and uniform zirconia all-ceramic crowns, (4 322.86±610.07) N and (5 914.12±596.80) N in the 30° group, (5 264.82±883.76) N and (5 220.83±563.38) N in the 45° group and (4 900.42±345.41) N and (5 050.22±560.24) N in the 60° group, respectively. The fracture load of multi-layer zirconia all-ceramic crowns in the 30° group was significantly lower than that of homogeneous zirconia all-ceramic crowns(P < 0.05); there was no statistical significance in 45° group and 60° group(P>0.05). In the multi-layer zirconia all-ceramic crowns: the fracture load of the 30° group was significantly lower than that of the 45° group (P < 0.05); there was no significant difference between the 30° group and the 60° group, the 45° group and the 60° group (P>0.05).In uniform zirconia full crown group: the 30° group was higher than the 45° group, the 30° group was higher than the 60° group (P < 0.05), and there was no significant difference between the 45° group and the 60° group (P>0.05).@*CONCLUSION@#The fracture loads of three kinds of uniform and multilayer zirconia all ceramic crowns with different edge compensation angles can meet the clinical requirements. A smaller edge compensation angle is recommended when using traditional zirconia all-ceramic crowns, while 45° is recommended when using multi-layer zirconia all-ceramic crowns.


Assuntos
Cerâmica , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Resistência à Flexão , Teste de Materiais , Zircônio
14.
Chinese Medical Sciences Journal ; (4): 252-256, 2021.
Artigo em Inglês | WPRIM | ID: wpr-921875

RESUMO

Computed tomography (CT) examination is the major measure for detecting and diagnosis of foreign bodies in human body. Although CT has high sensitivity in diagnosis of foreign body, some interference factors may still lead to missed diagnosis or misdiagnosis. Here we report a rare case that a bamboo stick accidentally pierced into the left chest of a young man who was drunk and unware of this hurt. The patient experienced cough, chest pain, fever, hemoptysis, and was misdiagnosed as primary and secondary tuberculosis based on chest CT examinations at a local hospital, although no tubercular bacillus detected by sputum smear. He subsequently received anti-tuberculous treatments in the following three years, but no improvement of his symptoms was observed. Until one month before his death, the bamboo stick was detected by spiral CT examination as well as three-dimensional image reconstruction at another hospital. Postmortem examination revealed pneumonia, pulmonary infarction, and abscess as the causes of his death. We analyze the potential reasons of misdiagnosis in this case, aiming to provide reference for the diagnosis and treatment of pulmonary inflammation associated with foreign body in the future.


Assuntos
Humanos , Masculino , Abscesso , Erros de Diagnóstico , Pneumonia , Infarto Pulmonar , Tuberculose Pulmonar
15.
Chinese Journal of Gastrointestinal Surgery ; (12): 173-178, 2021.
Artigo em Chinês | WPRIM | ID: wpr-942882

RESUMO

Objective: Anatomic variations in the perigastric vessels during laparoscopic radical gastrectomy often affect the operator's judgment and prolong the operation time, and even cause accidental injury and surgical complications, and hence the safety and quality of the operation cannot be ensured. In this study, multiple slice CT was reconstructed by 3-dimensional CT simulation software (3D-CT), and 3D-CT images were used to describe the variation of celiac trunk and splenic artery before surgery. The guiding role of the different variation of vessels was analyzed for laparoscopic total gastrectomy+D2 lymph node dissection (LTG+D2LD). Methods: A retrospective cohort study was conducted. Case inclusion criteria: (1) Gastric cancer was at an advanced stage. All the patients were preoperatively examined by digestive endoscopy and 64-row enhanced CT scan, and were histopathologically diagnosed with gastric adenocarcinoma. (2) 3D-CT simulation images were reconstructed to guide the operation. (3) LTG+D2LD surgery was performed by the same surgical team. (4) Clinical data were complete, and all the patients had signed the informed consent. From 2014 to 2018, 98 patients with gastric cancer at the Gastrointestinal Surgery Department of Henan Provincial People's Hospital were enrolled. According to the Adachi classification, celiac trunk variation was divided into common type (Adachi type I) and rare type (Adachi type II-VI). According to the Natsume classification, splenic artery was classified into "flat type" and "curved type". Based on 3D-CT simulation images, variation of celiac trunk and splenic artery was described, and the differences in operation time, intraoperative blood loss and the number of postoperative retrieved lymph nodes were compared between groups with different types of arterial variation. Results: For celiac trunk, common type was found in 84 cases (86%) and rare type was found in 14 cases, including 6 cases (6%) of type II, 2 cases (2%) of type III, 2 cases (2%) of type IV, 3 cases (3%) of type V, 1 case (1%) of type VI. No other types were found. There were no statistically significant differences in clinical characteristics and number of retrieved lymph nodes between patients of the common type group and rare type group (all P>0.05). Compared with common type patients, those of rare type had longer operative time [(321.1±29.0) minutes vs. (295.1±46.5) minutes, t=2.081, P=0.040] and more intraoperative blood loss (median: 66.0 ml vs. 32.0 ml, Z=-4.974, P=0.001). For splenic artery, 41 patients (42%) were flat type and 57 patients (58%) were curved type. There were no statistically significant differences between the two groups in terms of clinical characteristics, intraoperative blood loss, operative time and number of retrieved lymph nodes (all P>0.05). Conclusions: The method of describing the variation in the perigastric vessels by 3D-CT simulation has certain clinical value in laparoscopic radical gastrectomy. The duration of LTG+D2LD is prolonged and the intraoperative blood loss is increased with the variation of celiac trunk, while the variation of splenic artery has no effect on LTG+D2LD.


Assuntos
Humanos , Simulação por Computador , Gastrectomia , Artéria Gástrica/diagnóstico por imagem , Imageamento Tridimensional , Laparoscopia , Excisão de Linfonodo , Estudos Retrospectivos , Estômago/diagnóstico por imagem , Neoplasias Gástricas/cirurgia , Tomografia Computadorizada por Raios X
16.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 147-154, 2020.
Artigo em Chinês | WPRIM | ID: wpr-862706

RESUMO

<b>Objective::To establish the HPLC fingerprint of aqueous extract of Citri Reticulatae Pericarpium, and research the spectrum-effect relationship in diabetic cognitive dysfunction rats. <b>Method::The HPLC fingerprints of 21 batches of Citri Reticulatae Pericarpium were established, with acetonitrile (A)-0.1%of phosphoric acid (B) as the flow phase for gradient elution. The detection wavelength was 270 nm. Acomparative analysis was performed for the results based on similarity evaluation, SPSS 24.0 two-dimension clustering analysis and SIMCA 14.1 principal component analysis of fingerprint software. Thediabetic rat model wasduplicated by one-time intraperitoneal injection with streptozotocin (STZ) at the dose of 50 mg·kg<sup>-1</sup>. After successful replication of the model, thediabetic rats were given aqueous extract of Citri Reticulatae Pericarpium by gavage. The blood glucose value was determined at regular intervals. The cognitive function was analyzed with Morris water maze experiment at the 12 week. Grey relational analysis (GRA) and partial least squares regression analysis were used to study the spectrum-effect relationship. <b>Result::Totally 16 common peaks of water extract of Citri Reticulatae Pericarpium were confirmed, five substances were identified, and 21 species of Citri Reticulatae Pericarpium of different varieties and origins were divided into 2 categories. Compared with the model group, the blood glucose of rats in each group treated with water extract of Citri Reticulatae Pericarpiumwere reduced, and their cognitive function was improved.According to the grey correlation analysis and the least partial square regression analysis, the peaks No. 19, 15, 4, 17 and 6 were significantly correlated with the cognitive function of diabetic rats. <b>Conclusion::There were some differences in aqueous extract of Citri Reticulatae Pericarpium between different varieties and origins. It is convenient and fast to make a comprehensive quality evaluation of aqueous extract of Citri Reticulatae Pericarpium of different varieties and producing areas by stoichiometry, and aqueous extract of Citri Reticulatae Pericarpium can reduce the blood glucose level and improve the cognitive function of diabetic cognitive dysfunction rats, its mechanisms of action are resultedfrom the joint effects of multiple effective components, and peaks No. 19, 15, 4, 17 and 6 are components closely related to the cognitive function of diabetic rats.

17.
Journal of Peking University(Health Sciences) ; (6): 76-82, 2020.
Artigo em Chinês | WPRIM | ID: wpr-942144

RESUMO

OBJECTIVE@#To establish the workflow of determining the jaw position of repositioning splint with the aid of digital technique, and to evaluate the accuracy of this workflow and compare the accuracy of raising different vertical dimensions in vitro.@*METHODS@#A volunteer was recruited. The data of full-arch scans, cone beam computed tomography (CBCT) image and ultrasonic jaw motion tracking of the volunteer were acquired. The full-arch scans were merged with the CBCT image, which were then matched to the jaw motion tracking reference system. The jaw position of repositioning splint was determined when the anterior teeth opening was 3 mm and the condyle was in centric relation of the fossa in the sagittal plane. A digital repositioning splint was designed in the software based on virtual articulator and fabricated with additive manufacturing technique. After the splint was tried in, another CBCT image was taken and a qualitative analysis was conducted to compare the position of condyle between these two CBCT images. In the in vitro study, standard dental plaster casts with resin ball markers attached to the base were mounted onto a fully adjustable articulator in the intercuspal position. The dental casts were scanned by an extraoral scanner to establish digital models. The ultrasonic jaw motion tracking device was used to obtain simulated jaw movements on the articulator, which was repeated for three times. The digital models and data of jaw movements were merged in one coordination with the aid of bite forks. The jaw position of repositioning splint was determined by adjusting data of jaw movements, each of which was used to determine three vertical jaw positions 4 mm, 5 mm, and 6 mm with the horizontal jaw position of protrusion 2 mm. The virtual articulators with differently adjusted jaw movements were applied in designing repositioning splints, and the final repositioning splints and virtual jaw relationships were exported in STL format. Then the repositioning splints were fabricated with additive manufacturing technique and tried in plaster casts on the mechanical articulator, which were scanned and the jaw relationships on the mechanical articulator were exported later. The virtual jaw relationships and scanned jaw relationships were registered according to lower models and displacement of upper models was calculated. Ball markers were fit to acquire the coordinates of centers and absolute difference values of centers along three coordinating axes X, Y, and Z were calculated. One-way analysis of variance was conducted using SPSS 18.0 software to compare deviations of the three different vertical jaw relationships in two-side test and the significance level was 0.05.@*RESULTS@#With the aid of multi-source data fusion and individualized jaw motion, the clinical workflow of determining jaw position of repositioning splint was preliminarily established. The designed jaw position was realized on the right and the condyle was more inferior than the designed position on the left. Both displacement of the upper models and absolute difference values of centers showed no significant differences (P>0.05) in different vertical jaw dimensions. The displacement of the upper models was (0.25±0.04) mm. The absolute difference values of centers along the three coordinating axes X, Y, and Z were respectively (0.08±0.01) mm, (0.30±0.02) mm, and (0.21±0.04) mm.@*CONCLUSION@#A novel method of determining the jaw position of repositioning splint with the aid of digital technique is established. It is proved to be feasible by try-in after multi-data fusion, computer-aided design and computer-aided manufacturing. As is shown in vitro, it is accurate to apply this method in adjusting jaw position. Further clinical trial will be designed to evaluate its clinical effect.


Assuntos
Humanos , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Articuladores Dentários , Registro da Relação Maxilomandibular , Placas Oclusais , Software , Contenções
18.
Journal of Peking University(Health Sciences) ; (6): 762-770, 2020.
Artigo em Chinês | WPRIM | ID: wpr-942074

RESUMO

OBJECTIVE@#To compare the clinical efficacy of a kind of complete dentures fabricated using computer aided design/computer aided manufacturing (CAD/CAM) workflow with that of the complete denture fabricated using conventional workflow.@*METHODS@#Twenty edentulous patients were included in this prospective, single-blind, self-controlled clinical trial. Two pairs of complete dentures were fabricated for each participant: one using the functional suitable denture (FSD) system with CAD/CAM, and the other using conventional fabrication workflow. In the final delivery appointment, the conventional dentures worn by the participant for 3 months at first. Then the participant swapped to wear digital denture for another 3 months. The patients' satisfaction and oral health related quality of life (OHRQoL) were measured using the visual analogue scale (VAS) and oral health impact profile (OHIP-20E) at baseline, 2 weeks, 1 month, 2 months, and 3 months following denture delivery. In addition, the masticatory efficiency of each pair of dentures was measured after three months adaptation period for each type of dentures.@*RESULTS@#The VAS scores of the twenty patients in FSD denture group on general satisfaction, ease of cleaning, ability to speak, esthetics, stability and oral health status on these six domains were higher than that of conventional denture group 3 months after delivery. While the VAS cores in FSD denture group on comfort, ability to chew and ability to chew up were the same as those of conventional denture group. But there was no significant difference (P>0.05). The VAS score on each domain in FSD denture group was higher than that of conventional denture group 3 months after delivery, three domains of which reached statistical significance (P < 0.05), involving functional limitation, psychological discomfort and total. The masticatory performance of the FSD denture (1.20±0.54) was slightly higher than that for the conventional denture (1.16±0.53), but the difference did not reach statistical significance (P=0.691).@*CONCLUSIONS@#The clinical efficacy of the FSD complete denture is comparable to that of the conventional complete denture. As for patient satisfaction and oral health related quality of life, FSD dentures received comparable scores as conventional complete dentures did.


Assuntos
Humanos , Prótese Total , Satisfação do Paciente , Estudos Prospectivos , Qualidade de Vida , Método Simples-Cego , Resultado do Tratamento
19.
Journal of Peking University(Health Sciences) ; (6): 390-394, 2020.
Artigo em Chinês | WPRIM | ID: wpr-942017

RESUMO

Fabrication of conventional complete dentures involves a complex restoration method, requiring significant time and typically involving primary impressions, definitive impressions, jaw relation records, clinic try-in, and complete denture placement, which has been used for nearly a century without change. A novel digital system named Functionally Suitable Denture (FSD) was researched and developed so as to reduce clinical steps, operation difficulties and errors of complete denture restoration. It pioneered a unique diagnostic complete denture aided by computer aided design (CAD) & 3D printing, by which, the functional impression, jaw relation, and try-in (3 steps) were simplified to 1 step, thus the number of visits to the dentist was reduced by 2 times. Moreover, for the first time, it put forward a CAD software of template matching based on the expert design, which was an efficient and intelligent design scheme, and the excellent denture experts' experience and skills could be inherited and iterated. The system included the 3D scanner with appropriate accuracy and high efficiency, the CAD software, the special 3D printer and process software, and the innovative clinical operation process. The Patent Cooperation Treaty (PCT) patent international search report showed that all the 15 claims of the technology were of novelty, creativity and industrial utility. All the digital products were independently developed and made by Peking University School and Hospital of Stomatology, China. The design and manufacture process of denture prosthesis was fast, simple and accurate. At the same time, personalized functional and aesthetic matching of the patients after wearing prosthesis was realized. It effectively solved the global problems of "slow, difficult and inaccurate" of the traditional manual technology of complete denture, and brought good news to edentulous patients. Compared with the traditional complete denture treatment, FSD system has a wide range of applications for different types of edentulous patients, including those with severe resorption of the alveolar ridge or a high occlusal force. Furthermore, the low-cost of 3D printers, compared with expensive milling machines, may make the approach more accessible. This review describes that our research is related to the development of the FSD system, including multi-source data acquisition technology, three generations of complete denture design software, 3D printing systems of individual tray and complete denture pattern, the clinical and laboratory operation process of the FSD system.


Assuntos
Humanos , China , Desenho Assistido por Computador , Criatividade , Prótese Total , Boca Edêntula
20.
Journal of Peking University(Health Sciences) ; (6): 368-372, 2020.
Artigo em Chinês | WPRIM | ID: wpr-942013

RESUMO

OBJECTIVE@#To measure the dimensional data of complete dentures and to design a novel tray for recording maxillomandibular relationship of edentulous patients.@*METHODS@#For the measurement, 100 pairs of complete dentures from the clinic were surveyed for the following parameters: a1, the distance between the middle fossa of the upper left and right first molars; a2, the anterior-posterior distance between the middle fossa of the upper first molars and the incisal edge; a3, the width of the upper denture; a4, the anterior-posterior length of the upper denture; a51, the height from the mesio-lingual cusp of the right upper first molar to the saddle surface; a52, the height from the central fossa of the right lower first molar to the saddle surface; a6, the height from the notch of the upper lip frenulum to the upper central incisor edge; a7, the least thickness of the labial saddle base in the upper central incisor region. Based on the data, the trays with different sizes were designed and fabricated, and the key parameters were: b1, the distance between the foramina of screw posts, b2, the anterior-posterior distance between the foramina of the screw posts and the incisal edge; b3, the width of the tray; b4, the anterior-posterior length of the tray; b51, the height of the posterior platform with the screw nut; b52, the height of the screw post; b6, the height of the anterior tray handle; b7, the thickness of the anterior tray handle.@*RESULTS@#The minimum, average and maximum data for each parameter were (in millimeter): a1: 37.1, 44.5, and 59.6; a2: 22.6, 29.0, and 38.1; a3: 48.5, 58.2, and 76.6; a4: 37.4, 50.8, and 61.0; a51: 5.6, 9.5, and 14.7; a52: 3.8, 9.9, and 18.8; a6: 8.9, 16.6, and 24.7; a7: 1.2, 2.8, and 5.9. Based on the data, the trays in small, medium and large sizes were designed and fabricated. In clinical application, the putty silicone rubber impression material was used to reline the tray, meanwhile the posterior platform and anterior tray handle were set as the occlusal plane, then the screw posts were added and adjusted till the proper vertical dimension, after that, the putty silicone rubber impression material was added around the screw posts to record the horizontal maxillomandibular relationship, finally, the anterior surface of the tray handle was used to record the midline of the face and lower edge of the upper lip at rest and with smile.@*CONCLUSION@#The dimensional data offered reference for the analysis of restoration space in edentulous patients. The tray designed and fabricated in this study may serve as a new tool for recording the maxillomandibular relationship.


Assuntos
Humanos , Técnica de Moldagem Odontológica , Prótese Total , Incisivo , Lábio , Boca Edêntula , Dimensão Vertical
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA