Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Artigo em Chinês | WPRIM | ID: wpr-1024411

RESUMO

Tricuspid regurgitation(TR)is a common heart valve disease.According to the pathogenesis,TR can be divided into primary(organic)and secondary(functional)regurgitation,of which functional TR accounts for more than 90%.Patients with severe TR have poor prognosis and poor drug treatment,and surgery(valvuloplasty)is the main treatment.At present,transcatheter edge-to-edge tricuspid valve repair(T-TEER)has become an essential program of transcatheter treatment for TR,providing minimally invasive treatment for TR patients who cannot undergo surgery or are at high risk of surgery.T-TEER reduces the degree of regurgitation by clamping leaflets,and is currently in the early stage of research and development exploration and clinical validation,mainly for functional TR.T-TEER devices have also made significant progress(TriClip,PASCAL),and Chinese-made novel-designed T-TEER devices are also undergoing clinical trials(DragonFly-TTM,SQ-Kyrin-TTM,NeoBlazarTM).This paper reviews the current applications and research progress of T-TEER.

2.
Chinese Journal of Cardiology ; (12): 832-837, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1045703

RESUMO

Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Insuficiência da Valva Mitral/etiologia , Estudos Retrospectivos , População do Leste Asiático , Implante de Prótese de Valva Cardíaca , Resultado do Tratamento , China , Insuficiência Cardíaca/etiologia , Cateterismo Cardíaco
3.
Chinese Journal of Cardiology ; (12): 832-837, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1046026

RESUMO

Objective: To evaluate and compare the short-term efficacy of domestic mechanical-locked (Clip2Edge) and elastic self-locked (ValveClip) transcranial mitral valve edge-to-edge interventional repair (TEER) devices in the treatment of functional mitral regurgitant valves. Methods: In this retrospective non-randomized comparative study, patients underwent TEER procedure in Fuwai Yunnan Cardiovascular Disease Hospital from May 2022 to April 2023 for heart failure combined with moderate to severe or severe functional mitral valve were divided into Clip2Edge and ValveClip groups based on the TEER system used. Baseline, perioperative, and postoperative 30 d follow-up data were collected and compared between the two groups. The primary outcome was the success rate on the 30 d post operation, while secondary outcomes included immediate postoperative technical success rate and the incidence of all-cause mortality on the 30 d post operation, readmission rate of acute heart failure, cerebral infarction, severe bleeding, and other serious adverse events rates. Results: A total of 60 patients were enrolled, 34 patients were in the Clip2Edge group and 26 in the ValveClip group, mean age was (63.8±9.3) years, and 24 patients (40%) were female. There were no significant differences in baseline data of age, cardiac function, comorbidities, mitral regurgitation 4+(19(73%) vs. 29(85%)), the end-diastolic volume of left ventricle ((220.8±91.2) ml vs. (210.8±71.7) ml) between the two groups (all P>0.05). The technical success rate immediately after the procedure was 100%. There were no readmission of acute heart failure, death, cerebral infarction, severe bleeding, and other serious adverse events up to the 30 d follow-up. Device success rate was similar between the ValveClip group (24 cases (100%)) and the Clip2Edge group (27 cases (96%)) (P>0.05). Conclusion: Both types of novel domestic TEER devices are safe and feasible in treating patients with functional mitral regurgitation.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Insuficiência da Valva Mitral/etiologia , Estudos Retrospectivos , População do Leste Asiático , Implante de Prótese de Valva Cardíaca , Resultado do Tratamento , China , Insuficiência Cardíaca/etiologia , Cateterismo Cardíaco
4.
Journal of Medical Postgraduates ; (12): 515-520, 2020.
Artigo em Chinês | WPRIM | ID: wpr-821884

RESUMO

ObjectiveThe traditional detection method of recombinase polymerase amplificaton (RPA) is not suitable for rapid field detection due to the complicated operation and other factors. Taking the detection of hepatitis b virus (HBV) nucleic acid as an example, it established a detection method of HBV nucleic acid isothermal amplification based on recombinase polymerase amplificaton (RPA) and designed a matching visual detection device of RPA product.MethodsFirstly, a RPA product detection device was designed, which can be used to collect images by taking photos of mobile phones and visually interpret the detection results. Secondly, RPA primers and probes were designed according to the design of HBV gene conserved sequence. Amplification efficiency of each primer pairs were compared though monitoring the RPA reaction of real-time fluorescence curve to screen the best primers and optimize the optimal reaction conditions. Visual detection sensitivity was investigated by using artificial synthesis of HBV target plasmid, and was investigated the specificity of the method by the detection of synthetic plasmid containing hepatitis c virus (HCV), human immunodeficiency virus, treponema pallidum, influenza virus, human papilloma virus DNA fragment. Thirdly, the feasibility of RPA product visualization detection device was verified by comparing with the real-time fluorescence amplification curve. Finally, RPA visual detection was performed on 20 serum DNA samples detected by real-time fluorescence PCR to evaluate the applicability of this method to the detection of actual clinical samples.ResultsThe visual detection device of RPA product was used to realize the negative and positive signals that could be detected by mobile phone photography and visual observation. The visual detection method of HBV nucleic acid RPA amplification could realize the visual detection of DNA targets as low as 1-10 copies of HBV within 30 min at 39 ℃ and had good specificity. The test results of 20 serum DNA samples were completely consistent with those of the commercially available qPCR kit, which preliminarily verified the practicability of the method and the device.ConclusionCombined the established HBV-RPA amplification system with the RPA product visualized detection device, it would be expected to develop a low-cost rapid visualization screening technology platform for HBV nucleic acid in blood.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA