Chinese Journal of Radiology ; (12): 708-712, 2015.
Artigo em Chinês | WPRIM | ID: wpr-478853

RESUMO

Objective To establish the animal model of chronic thromboembolic pulmonary hypertension(CTEPH) and to compare the accuracy of dual-energy CT (DECT) pulmonary angiography and histopathology for detecting CTEPH. Methods Eighteen canines were included in the study. All canines underwent paracentesis, embolization, CT scanning, pressure measurement and tranexamic acid feeding. The procedures were repeated every two weeks, until systolic/diastolic pressure in canines was≥30/15 mmHg or mean pulmonary artery pressure ≥ 20 mmHg.And then canines were sacrificed for histopathology examination. For CT pulmonary angiography (CTPA)in DE mode and DECT lung perfused blood volume (Lung PBV) images, the presence or absence of PE or perfusion defects were recorded on a per-canineand aper-lobe basis. With histopathological results as reference standard, the sensitivity, specificity of CTPA and lung PBV to detect PE were computed for two readers. The pairedχ2 test (McNemar test) was used to analyze the difference in diagnostic accuracy between CTPA and Lung PBV. Inter-reader agreement was also calculated with kappa test. Results CTEPH was demonstrated in 13 canines. On a per-canine basis, both readers found uneven and peripheral perfusion defects with DECT in 11 canines (84.6%, 11/13); while 5 canines (38.5%, 5/13) had cutoff or sudden stenosis of pulmonary arteries with CTPA;on a per-lobe basis, both readers had sensitivities of 14.3%(5/35), 83.3%(30/36), specificities of 100.0%(30/30), 100.0%(29/29), accuracies of 53.8%(35/65), 90.8%(59/65)for CTPA and DECT, respectively. DECT had a higher sensitivity(χ2=-4.690,P<0.01)and accuracy(χ2=8.284,P<0.01) in detecting CTEPH. Excellent and moderate inter-reader agreements were observed with CTPA and DECT (Kappa=0.938, 0.572, both P<0.001). Conclusions It is feasible to make a CTEPH animal model with autologous thrombus. DECT shows a higher accuracy than CTPA to detect CTEPH in this canine model study.

2.
Chinese Journal of Radiology ; (12): 912-916, 2013.
Artigo em Chinês | WPRIM | ID: wpr-442369

RESUMO

Objective To evaluate the value of dual energy CT with Lung Vessels application in diagnosing pulmonary embolism (PE) of children.Methods Forty-seven patients with nephrotic syndrome and aged ≤ 18 years old (32 male,15 female,mean age 15 years) underwent dual-energy CT pulmonary angiography (CTPA).Two radiologists recorded the presence or absence of emboli and counted the clots on a per-patient and per-lobe basis with Lung Vessels,respectively.With conventional CTPA as reference standard,sensitivity,specificity,positive predictive value (PPV),negative predictive value (NPV) of Lung Vessels application to detect PE were computed for two readers.Inter-reader agreement was also calculated.Results Conventional CTPA detected 51 clots in 35 lung lobes in 13 patients,giving PE incidence was 27.6% (13/47) for this cohort.On a per-patient basis,readers 1 and 2 detected 25 and 21 patients with PE with Lung Vessels,corresponding to sensitivities,specificities,PPVs,and NPVs of 100.0% (13/13),58.6% (17/29),43.3% (13/30),100.0% (17/17) and 100.0% (13/13),76.5% (21/29),50.0% (13/26),100.0% (21/21),respectively.On a per-lung lobe basis,readers 1 and 2 detected 74 and 63 clots with Lung Vessels,respectively,corresponding to sensitivities,specificities,PPVs,and NPVs of 94.3% (33/35),79.5% (159/200),44.6% (33/74),98.7% (159/161) and 97.1% (34/36),85.5% (171/200),54.0% (34/63),98.8% (171/173),respectively.On a per-clot basis,134 and 105 clots were detected with Lung Vessels application,corresponding to sensitivities,specificities,PPVs,and NPVs for DECT of 96.1% (49/51),64.9% (159/245),36.3% (49/135),98.7% (159/161) and94.1% (48/51),75.0% (171/228),45.7% (48/105),98.3% (171/174)for readers 1 and 2,respectively.Excellent or good inter-reader agreement was observed on a per-patient,per-lobe and per-clot basis (Kappa =0.828,0.859,0.695 ; all P < 0.01).Conclusions Dual-energyCT with Lung Vessels application has a high sensitivity and negative predictive value for PE detection in children.More clots are detected with Lung Vessels application than conventional CTPA,which deserve further investigation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA