Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Artigo em Espanhol | LILACS-Express | LILACS, LIPECS | ID: biblio-1522596

RESUMO

Diversos estudios han demostrado que un clampaje tardío del cordón umbilical aumenta los niveles de hemoglobina de los recién nacidos. Objetivos: Evaluar si el clampaje tardío del cordón umbilical en neonatos a término muestra mayores valores de hemoglobina que cuando se realiza clampaje precoz, a 2700 msnm. Diseño: Investigación prospectiva, aleatorizada y doble ciego. Institución: Departamento de GinecoObstetricia, Hospital Regional de Cajamarca, Perú. Participantes: Recién nacidos y sus madres. Métodos: En enero de 2014, a 100 gestantes en trabajo de parto con gestación única, a término y sin otros factores de riesgo, se asignó al azar clampaje tardío (cuando dejó de latir el cordón umbilical 1 a 3 minutos) o clampaje precoz (alrededor de 10 segundos después del parto). Se midió el tiempo desde que aparecieron los hombros del bebé. Se procedió a sacar una muestra de sangre del talón derecho del recién nacido en 2 capilares y a las 6 horas de vida, y se analizó la hemoglobina, el hematocrito y grupo y factor Rh. Principales medidas de resultados: Nivel de hemoglobina. Resultados: Encontramos 91 % de gestantes sin anemia y 9% con anemia; el grupo sanguíneo materno predominante fue el O+ en 86%. Se practicó clampaje tardío a 52 recién nacidos y clampaje precoz a 48. El 94% de los recién nacidos pesó entre 2 501 Y 3 999 g, con Ápgar > 7 en el 100%. El tiempo en que dejó de latir el cordón umbilical fue 2,67+-0,28 minutos. En 100% de los neonatos con clampaje temprano el valor de la hemoglobina fue <15 mg/dLy en el clampaje tardío el 71,1 % presentó hemoglobina de 15,1 a 20,1 mg/dL, y 28,9% más de 20,1 mg/dL. No hubo diferencia significativa en los valores de hemoglobina de los recién nacidos sí la madre presentó o no anemia. Conclusiones: El clampaje tardío mostró mejores valores de hemoglobina en los neonatos. El tiempo medio en que dejó de latir el cordón fue 2,67 min y la anemia materna no influyó en la hemoglobina neonatal.


Several studies have shown that late cord clamping in creases levels of hemoglobin in newborns. Objectives: To determine whether delayed umbilical cord clamping in term infants show higher hemoglobin levels than early clamping, investigation performed at 2700 m.a.s.l. Design: Prospective, randomized, double blind study. Setting: Gynecology and Obstetrics Department, Hospital Regional de Cajarnarca, Peru. Participants: Newborns and their moth­ ers. Methods: In january 2014, 100 pregnant women in labor with singleton pregnancies at term and without other risk factors were randomized to delayed clamping (when the umbilical cord stopped beats in 1-3 minutes) or early clamping (about 1 O seconds after birth). Time was measured starting when baby shoulders appeared. A blood sample from the right newborn's heel was obtained and placed in 2 capillaries, at birth and also at 6 hours of life; hemoglobin, hematocrit, and group and Rh factor were analyzed. Main outcome measures: Hemoglobin levels. Results: Ninety-one per cent of pregnant women did not have anemia and 9% had anemia; maternal blood group was 0+ in 86%; 94% of newborns weighed 2 501-3 999 g, Apgar >7 was found in all newborns. Late clamping was done in 52 infants and early clamping in 48. The umbilical cord stopped beating at 2.67+-0.28 minutes. In 100% of infants with early clamping hemoglobin value was <15 mg/dL, and in late clamping 71.1 % had hemoglobin 15.1­ 20.1 mg/dL and 28.9% over 20.1 mg/dL. There was no significant difference in newborn hemoglobin values whether the mother presented anemia or not. Conclusions: Late clamping resulted in better neonatal hemoglobin values. Average time for the umbilical cord stopping beats was 2.67 mino Maternal anemia did not affect neonatal hemoglobin at 2 700 m.a.s.l.

2.
Artigo em Espanhol | LILACS-Express | LILACS, LIPECS | ID: biblio-1522583

RESUMO

Introducción: La eclampsia es una de las complicaciones más severas de la preeclampsia. Objetivos: Identificar las características epidemiológicas, clínicas y complicaciones materno-fetales de pacientes eclámpticas a 2 700 m.s.n.m. Diseño: Estudio descriptivo. Institución: Servicio de GinecoObstetricia del Hospital Regional de Cajamarca, Perú. Participantes: Mujeres con diagnóstico de eclampsia y sus fetos y recién nacidos. Métodos: Estudio de 28 casos con diagnóstico de eclampsia de 3 128 partos atendidos entre el primero de enero de 2012 y el 31 de diciembre de 2012, a 2700 m.s.n.m. Principales medidas de resultados: Características materno-fetales. Resultados: La incidencia de eclampsia fue 0,9%, un caso por cada 113 partos. La edad promedio de la mujer con eclampsia fue 23,3 +- 6,5 años; 46,4% eran primigestas, la procedencia era rural en 71,4%; 46,4% de las mujeres tenía más de 6 controles prenatales; en 53,6% se halló presión arterial > o = 160/110. El cuadro de eclampsia se presentó antes del parto en 78,6% y 71,4% terminó por cesárea. El número de convulsiones fue más de dos en 74,7%. El síntoma más frecuente fue la cefalea en 89,2%. La creatinina estuvo elevada en 35,7%, las transaminasas en 39,2%, hubo anemia en 64,3% y trombocitopenia en 32,1%. Fueron complicaciones maternas el síndrome Hellp en 25% y la muerte materna en 3,4%; en los perinatos, prematuridad en 60,7%, restricción de crecimiento intrauterino en 39,3% y muerte fetal en 13,7%. Conclusiones: La eclampsia a 2 700 msnm se asoció a alta morbimortalidad materna y fetal.


Introduction: Eclampsia is one of the most severe complications of preeclampsia in pregnancy. Objectives: To identify the epidemiological, clinical and maternal fetal complications of women suffering of eclampsia at 2 700 meters above sea level. Design: Descriptive study. Setting: Service of Gynecology and Obstetrics, Hospital Regional de Cajamarca, Peru. Participants: Women with diagnosis of eclampsia and their fetuses and newborns. Methods: Study of 28 cases of women with diagnosis of eclampsia of a total of 3 128 deliveries attended between January 2012 and December 2012, at 2700 meters above sea level. Main outcome measures: Maternal and fetal characteristics. Results: Incidence of eclampsia was 0.9%, one case for each 113 deliveries. Main age of women with eclampsia was 23.3 +- 6.5 years; 46.4% carried their first pregnancy, origin was rural in 71.4%; 46.4% had over 6 prenatal controls; in 53.6% blood pressure was > or = 160/110. Eclampsia occurred before delivery in 78.6%, and 71.4% needed cesarean section. The number of seizures was more than two in 74.7%. Most frequent symptom was headache in 89.2%. Creatinine was high in 35.7%, transaminases were increased in 39.2%, anemia was present in 64.3% and thrombocytopenia in 32.1%. Maternal complications were HELLP syndrome in 25% and maternal death in 3.4%. Perinatal complications were prematurity in 60.7%, intrauterine growth restriction in 39.3% and fetal death in 13.7%. Conclusions: Eclampsia at 2 700 m.a.s.l. was associated to important maternal and fetal morbidity and mortality.

3.
Artigo em Espanhol | LILACS-Express | LILACS, LIPECS | ID: biblio-1522557

RESUMO

Objetivo: Determinar si la preeclampsia influye en los componentes (proteínas, lípidos, agua, crematocrito y contenido calórico) de la leche materna (calostro) de puérperas. Diseño: Investigación de tipo transversal, comparativa. Institución: Departamento de Ginecoobstetricia, Hospital Regional de Cajamarca, Perú. Participantes: Puérperas atendidas a 2 720 m.s.n.m. Métodos: En 25 puérperas con preeclampsia y 25 puérperas sin preeclampsia se recolectó calostro y se determinó el porcentaje de agua, proteínas, grasas y contenido calórico. Los datos fueron analizados con SPSS 21.0 y se comparó los resultados mediante la T de student pareada. Principales medidas de resultados: Porcentaje de agua, proteínas, grasas y contenido calórico del calostro. Resultados: El porcentaje de agua de no preeclámpticas fue 83,7+/- 1,1, y el de preeclámpticas 88,0+/-0,5. con p <0,01; el porcentaje de proteínas de no preeclámpticas fue 2,2+/-0,2, y el de preeclámpticas 1,9+/-0,3, con p<0,01; el porcentaje de grasas de no preeclámpticas fue 1,8+/-0,1 y el de preeclámpticas 2,1+/- 0,2, con p<0,01; el crematocrito de no preeclámpticas fue 3,9 +/-1,4 y el de preeclámpticas 5,0+/- 2,0, con p< 0,05; el valor calórico en kcal/mL de no preeclámpticas fue 52,1+/- 4,6, el de preeclámpticas 55,9+/- 6,8, con p< 0,05. Conclusiones: La preeclampsia influyó en los componentes del calostro, en la muestra estudiada a 2 720 m.s.n.m.


Objective: To determine preeclampsia influence on components (proteins, lipids, water, and caloric content of crematocrit) of colostrum in postpartum women. Design: Cross-sectional comparative study. Setting: Gynecology and Obstetrics service, Hospital Regional de Cajamarca, Peru. Participants: Puerperal women attended at 2 720 meters above sea level. Methods: Colostrum was collected from 25 puerperal preeclamptic women and 25 non-preeclamptic puerperae; percentage of water, proteins, fat and caloric content were determined. Data was analyzed using SPSS 21.0 and results compared using paired student T. Main out-come measures: Percentage of water, proteins, fat and caloric content in colostrum. Results: Non-preeclamptic water percentage in colostrum was 83.7 + / - 1.1, and in preeclamptic 88.0 + / -0.5, p <0.01; non-preeclamptic protein percentage was 2.2 + / -0.2, and in preeclamptic 1.9 + / -0.3, p <0.01; non-preeclamptic fat percentage in colostrum was 1.8 + / -0.1, and in preeclamptic 2.1 + / - 0.2, p <0.01; non-preeclamptic crematocrit was 3.9 + / -1.4, and in preeclamptic 5.0 + / - 2.0, p <0.05; caloric value in kcal / mL in non-preeclamptic was 52.1 + / - 4.6, and 55.9 + / - 6.8 in preeclamptic, p <0.05. Conclusions: Preeclampsia influenced colostrum components in the population studied at 2 720 meters above sea level.

4.
Artigo em Espanhol | LILACS-Express | LILACS, LIPECS | ID: biblio-1522513

RESUMO

Objetivos: Determinar si el acetato de medroxiprogesterona posparto produce variación en los niveles de grasas totales, calcio y crematocrito de la leche materna en transición y madura. Diseño: Estudio transversal y comparativo. Institución: Hospital Regional de Cajamarca, Perú, y Hospital Nacional Cayetano Heredia, Lima, Perú. Participantes: Madres lactantes. Intervenciones: En 1998, en el Hospital Nacional Cayetano Heredia se analizó 79 muestras de leche de madres lactantes en los primeros tres meses posparto; ellas recibieron acetato de medroxiprogesterona posparto (24) o no lo recibieron (controles, 55). Se determinó los valores de grasas totales, calcio y crematocrito. Principales medidas de resultados: Variación de valores de grasas totales, calcio y crematocrito. Resultados: En las mujeres que recibieron acetato de medroxiprogesterona posparto, los niveles de grasas totales fueron 4,8 +- 2,3 g/dL, y en los controles, 4,6 +- 2,9 g/dL; el calcio en los casos fue 55,6 +- 23,9 mg/dL y 55,5 mg/dL en los controles; y el crematocrito, en los casos 10,6 +- 3,8% y en los controles 11,7 +- 4,4%. No se encontró diferencias significativas. Conclusiones: El acetato de medroxiprogesterona posparto no modificó los valores de grasas, calcio y crematocrito de la leche materna en los primeros tres meses posparto.


Objectives: To determine whether postpartum medroxyprogesterone acetate produces variation in levels of total fat, calcium and crematocrit of transitional and mature milk. Design: Transversal and comparative study. Setting: Hospital Regional de Cajamarca, Peru and Hospital Nacional Cayetano Heredia, Lima, Peru. Participants: Lactating mothers. Interventions: In 1998 79 samples of maternal milk of mothers three months post partum were analyzed al Hospital Nacional Cayetano Heredia. These women either received medroxyprogesterone acetate (24) or not (55 controls). Total fat , calcium and crematocrit were determined. Main outcome measures: Total fat, calcium and crematocrit values. Results: In women receiving medroxyprogesterone acetate total fat levels were 4.8 +- 2.3 g/dL, and in controls, 4.6 +- 2.9 g/dL; calcium levels were respectively 55.6 +- 23.9 mg/ dL in cases and 55.5 mg/dL in controls; and crematocrit, 10.6 +- 3.8 in cases and 11.7 +- 4.4% in controls. There were no significant differences. Conclusions: Medroxyprogesterone acetate did not alter breast milk fat, calcium and crematocrit levels in the first three months postpartum.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA