Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Adicionar filtros








Intervalo de ano
1.
Dental press j. orthod. (Impr.) ; 19(4): 66-70, Jul-Aug/2014. tab
Artigo em Inglês | LILACS | ID: lil-725418

RESUMO

OBJECTIVE: The aim of this study was to assess the in vitro cytotoxicity of acrylic resins of different colors over time. METHODS: Specimens were divided into 4 groups (n = 6) according to the color of the acrylic resin (Orto Class, Clássico, Campinas, São Paulo, Brazil): Group 1: clear acrylic resin; group 2: pink acrylic resin; group 3: blue acrylic resin and group 4: green acrylic resin. All specimens were fabricated according to the mass manipulation technique and submitted to mechanical polishing protocol. The control was performed with an amalgam specimen (C+), a glass specimen (C-) and cell control (CC). Specimens were immersed in Minimum Eagle's Medium (MEM) and incubated for 24 h at 37o C. The extracts from the experimental material were filtered and mixed with L929 fibroblast. Cytotoxicity was evaluated at 4 different times, 24, 48, 72 and 168 h. After contact, cells were incubated for 24 h and added to 100 µ of 0.01% neutral red dye. The cells were incubated for 3 h for pigment incorporation and fixed. Cells viability was determined by a spectroscopic (BioTek, Winooski, Vermont, USA) with a 492-nm wavelength λ=492 nm). RESULTS: There were no statistical differences between the experimental groups and the CC and C- groups. CONCLUSION: Clear, pink, blue and green self-curing acrylic resins fabricated by means of the mass manipulation technique and mechanically polished are not cytotoxic. Neither the pigment added to the self-curing acrylic resin nor the factor of time influenced the cytotoxicity of the material. .


OBJETIVO: avaliar, in vitro, a citotoxicidade de resinas acrílicas autopolimerizáveis, de diferentes cores, ao longo do tempo. MÉTODOS: os corpos de prova foram divididos em quatro grupos (n = 3), de acordo com a cor da resina acrílica utilizada (Orto Class, Clássico, São Paulo/SP), sendo: grupo 1, acrílica incolor; grupo 2, acrílica rosa; grupo 3, acrílica azul; e, grupo 4, acrílico verde. Todos os corpos de prova foram confeccionados pela técnica de massa e polidos mecanicamente. Um corpo de prova de amálgama, um de vidro e célula constituíram o controle positivo (C+), controle negativo (C-), e controle de célula (CC), respectivamente. Em seguida, esses foram imersos em meio mínimo essencial de Eagle (MEM) por 24h, quando se removeu o sobrenadante e colocou-os em contato com fibroblastos L929. Avaliou-se a citotoxicidade em quatro períodos: 24, 48, 72 e 168h. Após o contato com o meio, as células foram incubadas por 24h e adicionou-se 100µ do corante vermelho neutro a 0,01%. Posteriormente, as células foram incubadas por 3h, para incorporação do corante, e fixadas. A contagem das células viáveis foi realizada em espectrofotômetro (BioTek, Winooski, EUA), com um comprimento de onda de 492nm (λ = 492nm). RESULTADOS: não houve diferença estatística entre os grupos experimentais e os grupos CC e C-. CONCLUSÇÕES: as resinas acrílicas autopolimerizáveis incolor, rosa, azul e verde, manipuladas pela técnica de massa e polidas mecanicamente não são citotóxicas. O corante utilizado em resinas autopolimerizáveis e tempo não influenciam na citotoxocidade do material. .


Assuntos
Animais , Camundongos , Resinas Acrílicas/toxicidade , Corantes/toxicidade , Materiais Dentários/toxicidade , Técnicas de Cultura de Células , Linhagem Celular , Cor , Sobrevivência Celular/efeitos dos fármacos , Amálgama Dentário/toxicidade , Polimento Dentário/métodos , Fibroblastos/efeitos dos fármacos , Vidro/química , Indicadores e Reagentes , Teste de Materiais , Vermelho Neutro , Polimerização , Análise Espectral , Propriedades de Superfície , Autocura de Resinas Dentárias/métodos , Temperatura , Fatores de Tempo
2.
Dental press j. orthod. (Impr.) ; 18(1): 63-68, Jan.-Feb. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-674265

RESUMO

OBJECTIVE: To evaluate the influence of saliva contamination on the bond strength of metallic brackets bonded to enamel with hydrophilic resin composite. METHODS: Eighty premolars were randomly divided into 4 groups (n = 20) according to bonding material and contamination: G1) bonded with Transbond XT with no saliva contamination, G2) bonded with Transbond XT with saliva contamination, G3) bonded with Transbond Plus Color Change with no saliva contamination and G4) bonded with Transbond Plus Color Change with saliva contamination. The results were statistically analyzed (ANOVA/Tukey). RESULTS: The means and standard deviations (MPa) were: G1)10.15 ± 3.75; G2) 6.8 ± 2.54; G3) 9.3 ± 3.36; G4) 8.3 ± 2.95. The adhesive remnant index (ARI) ranged between 0 and 1 in G1 and G4. In G2 there was a prevalence of score 0 and similar ARI distribution in G3. CONCLUSION: Saliva contamination reduced bond strength when Transbond XT hydrophobic resin composite was used. However, the hydrophilic resin Transbond Plus Color Change was not affected by the contamination.


OBJETIVO: avaliar a influência da contaminação por saliva na resistência de união de braquetes metálicos colados ao esmalte com um compósito resinoso hidrofílico. MÉTODOS: oitenta pré-molares foram divididos aleatoriamente em quatro grupos (n=20), de acordo com o material de colagem e a presença de contaminação - G1) colagem com Transbond XT na ausência de contaminação; G2) colagem com Transbond XT na presença de contaminação; G3) colagem com Transbond Plus Color Change na ausência de contaminação; G4) colagem com Transbond Plus Color Change na presença de contaminação. Os resultados foram tratados estatisticamente (ANOVA/Tukey). RESULTADOS: as médias e desvios-padrão (MPa) foram G1 = 10,15 ± 3,75; G2 = 6,8 ± 2,54; G3 = 9,3 ± 3,36; G4 = 8,3 ± 2,95. O índice de adesivo remanescente (IAR) variou entre 0 e 1 no G1 e no G4; no G2, houve predomínio do escore 0 e distribuição similar no G3. CONCLUSÃO: a contaminação por saliva reduziu a resistência de união no grupo que usou a resina hidrofóbica Transbond XT. Por outro lado, a resina hidrofílica Transbond Plus Color Change não foi influenciada pela contaminação.


Assuntos
Humanos , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/química , Colagem Dentária/métodos , Esmalte Dentário/química , Braquetes Ortodônticos , Saliva/química , Análise de Variância , Dente Pré-Molar , Interações Hidrofóbicas e Hidrofílicas , Resistência ao Cisalhamento
3.
Ortho Sci., Orthod. sci. pract ; 6(23): 279-284, 2013. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-707581

RESUMO

Avaliou-se a proporção carga/deflexão da alça ortodôntica em forma de “T” confeccionada com fio retangular de secção transversal 0,019” x 0,025” de ligas de aço inoxidável e beta-titânio de diferentes marcas comerciais. Foram confeccionadas 20 alças para fechamento de espaço provenientes de quatro grupos experimentais de acordo com a liga do fio ortodôntico e com a marca comercial utilizada na confecção da alça: G1 - aço inoxidável da marca comercial Morelli®; G2 - aço inoxidável da marca Ortho Organizers®; G3 - beta-titânio da Ormco™ e G4 - beta-titânio da Ortho Organizers®. As alças foram submetidas ao ensaio mecânico no qual as deflexões de 1,0 mm; 1,5 mm; 2,0 mm; 2,5 mm e 3,0 mm foram procedidas. A carga horizontal liberada pelas alças de beta-titânio, frente às diversas deflexões, foi menor em relação às alças de aço inoxidável com diferença estatisticamente significante (p<0,05). O comportamento dos fios de aço inoxidável Morelli® e Ortho Organizers® foi semelhante nas deflexões de 1,5 mm e 2,5 mm; nas demais ativações o fio da Morelli® conferiu menor proporção carga/deflexão à mola. Os fios de beta-titânio apresentaram resultados semelhantes nas ativações de 1,0 mm, 1,5 mm e 2,0 mm; nas demais ativações o fio da Ormco™ proporcionou menor valor de carga/deflexão do que o fio da Ortho Organizers®. Para a configuração de mola utilizada neste experimento a utilização de fios de beta-titânio confere menor proporção carga/deflexão e proporciona a liberação de força mais leve e constante em comparação aos fios de aço inoxidável.


It was assessed the load-deflection rate of beta-titanium and stainless steel T-loops constructed from 0.019”x0.025” orthodontic archwires of different manufactures. Twenty retraction loop springs were allocated into 4 experimental groups according to the trademark and alloy of the wire used: G1 - stainless steel from Morelli®; G2 - stainless steel from Ortho Organizers®; G3 - beta-titanium from Ormco™; G4 - beta-titanium from Ortho Organizers®. The specimens were submitted to the mechanical test in which the 1.0 mm; 1.5 mm; 2.0 mm; 2.5 mm; and 3.0 mm deflections proceeded. The horizontal load of beta-titanium T-loops was lower than the stainless steel for all deflections evaluated; with statistical significant difference (p<0.05). Tthe stainless steel groups (G1 and G2) showed similar behavior within the 1.5 mm and 2.5 mm deflections and the Morelli® wire (G1) lead the lower horizontal load within the other deflections. The beta-titanium alloy springs showed similar load values within the 1.0 mm, 1.5 mm, and 2.0 mm deflections and the Ormco™ T-loop presented lower load values compared to the Ortho Organizers® within the 2.5 mm and 3.0 mm deflections. For the T-loop sprig configuration the beta-titanium wire leads to lower load-deflection rate and leaches more constant and lower forces than the stainless steel wire.


Assuntos
Fios Ortodônticos , Ortodontia Corretiva , Aço Inoxidável , Titânio
4.
J. appl. oral sci ; 20(1): 89-93, Jan.-Feb. 2012. tab
Artigo em Inglês | LILACS | ID: lil-618159

RESUMO

OBJECTIVE: The aim of this study was to assess the impact of blood contamination on shear bond strength (SBS) and bond failure pattern of metallic brackets bonded using a new hydrophilic resin. MATERIAL AND METHODS: Eighty human premolars were randomly allocated into 4 groups (n=20) according to the bonding material and contamination pattern. GI: brackets bonded with the Transbond XT conventional system without contamination; GII: brackets bonded with the Transbond XT conventional system with blood contamination; GIII: brackets bonded with the Transbond Self Etching Primer and Transbond Plus Color without contamination; GIV: brackets bonded with the Transbond Self Etching Primer and Transbond Plus Color with blood contamination. The specimens were stored in distilled water at 37°C for 24 h and then submitted to SBS test at a crosshead speed of 0.5 mm/min. After bond failure, the enamel surfaces were observed under an optical microscope at 40x magnification. RESULTS: Blood contamination decreased (P<0.05) shear bond strength when both the hydrophobic (GII) and the hydrophilic resin (GIV) were used. However, the bond strength of Transbond Color Change group was significantly higher (P<0.05) than that of the Transbond XT conventional system group under blood contamination condition. Under dry conditions no difference was observed between the hydrophobic and hydrophilic resin groups. Regarding the bond failure pattern, when blood contaminated the enamel, the adhesive remnant index (ARI) showed predominance of scores 0 and 1, which indicates low adhesion to enamel. CONCLUSIONS: Although there was a significant decrease in the shear bond strength for both adhesive systems under blood contamination, the hydrophilic system showed significantly higher bond strength than the hydrophobic resin adhesive. Therefore, it is advisable to use the hydrophilic resin under risk of blood contamination.


Assuntos
Humanos , Sangue , Resinas Compostas/química , Colagem Dentária/métodos , Braquetes Ortodônticos , Cimentos de Resina/química , Análise de Variância , Contaminação de Equipamentos , Teste de Materiais , Distribuição Aleatória , Resistência ao Cisalhamento
5.
RGO (Porto Alegre) ; 57(3): 335-338, jul.-set. 2009. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-527916

RESUMO

Objetivo: Avaliar a topografia de superfície da resina acrílica autopolimerizável submetida a diferentes protocolos de manipulação. Métodos: Sessenta corpos de prova foram divididos aleatoriamente em quatro grupos (n=15), de acordo com o protocolo de manipulação: G1 - adição na presença de pressão; G2 - adição na ausência de pressão; G3 - massa na presença de pressão e G4 - massa na ausência de pressão. Após a polimerização da resina, todos os corpos de prova foram submetidos ao acabamento com lixas d'agua e polimento mecânico. A análise da topografia de superfície foi realizada utilizando um rugosímetro e cada corpo de prova foi mensurado duas vezes. Resultados: Os resultados foram tratados estatisticamente e as médias foram: G1 - 0,130µm; G2 - 0,120µm, G3 - 0,218µm e G4 - 0,192µm. A aplicação de ANOVA a um critério e Tukey indicaram diferença significante entre G1 e G3; G2 e G3 e G2 e G4. Conclusão: O método de manipulação parece influenciar as características físicas da resina acrílica autopolimerizável, além disso, o método de manipulação por adição diminuiu a rugosidade superficial.


Objective: The aim of this study was to evaluate the surface roughness of acrylic resin according to the manipulation method. Methods: Sixty specimens were randomly divided into four groups (n=15) according to the manipulation method: G1 - addition with pressure, G2 - addition without pressure, G3 - mass with pressure and G4 - mass without pressure. After resin polymerization, all specimens were submitted to finishing with abrasive paper and mechanical polishing. Topographical surface analysis surfaces was performed twice on each sample using the rugosimeter.Results: The results were statistically analyzed and means were: G1 - 0,130µm; G2 - 0,120µm, G3 - 0,218µm e G4 - 0,192µm. ANOVA for one criterion and the Tukey test showed significant difference between G1 and G3, G2 and G3, G2 and G4. Conclusion: The manipulation method seems to affect the physical characteristics of auto polymerized acrylic resin. The addition manipulation method decreased the surface roughness.


Assuntos
Resinas Acrílicas , Aparelhos Ortodônticos Removíveis/efeitos adversos , Fenômenos Físicos , Propriedades de Superfície
6.
Rev. Clín. Ortod. Dent. Press ; 8(4): 77-83, ago.-set. 2009. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-541946

RESUMO

Os dentes supranumerários são aqueles que excedem o número normal nas dentaduras decídua e permanente, e resultam, provavelmente, da proliferação contínua da lâmina dentária. Essa anomalia de número tem predileção pelo gênero masculino, na proporção de 2:1. Na dentadura permanente, o supranumerário mais frequente ocorre entre os incisivos centrais superiores, sendo denominado mesiodens. O diagnóstico é confirmado por meio de exame radiográfico e o tratamento ideal é a extração, quando possível, em fase precoce, para a prevenção de alterações na oclusão dentária estética do sorriso. O presente trabalho apresenta o tratamento ortodôntico de um paciente com mesiodens e má oclusão de Classe II, por meio da extração dos pré-molares superiores, do mesiodens e aplicação de biomecânica diferenciada. Resultado final satisfatório foi obtido e mantido na fase de contenção.


Assuntos
Humanos , Masculino , Adolescente , Fenômenos Biomecânicos/métodos , Dente Supranumerário/terapia , Extração Dentária , Má Oclusão Classe II de Angle/terapia
7.
Ortho Sci., Orthod. sci. pract ; 2(6): 604-607, 2009. ilus
Artigo em Português | LILACS, BBO | ID: lil-544227

RESUMO

O mento é parte integrante da face, juntamente com o nariz é um dos maiores determinantes da harmonia facial, porém muitas vezes é negligenciado no exame clínico e no planejamento do tratamento ortodôntico. A mentoplastia, frequentemente realizada como procedimento secundário em associação a cirurgia ortognática, consiste em importante recurso para a obtenção de estética facial. O diagnóstico e planejamento individualizado devem incluir as análises do esqueleto facial e dos tecidos moles do perfil total da face. Quando equilibrado no tamanho, forma e posição, o mento pode realçar a harmonia e a simetria da face. Dessa forma, a mentoplastia promove proporcionalidade, corrigindo ou minimizando o excesso ou a deficiênica do terço inferior da face, assim como assimetrias, proporcionando alto grau de satisfação para o paciente. O artigo está ilustrado com dois casos clínicos em que a mentoplastia, uma de aumento e outra de redução, consistiu em uma terapêutica com resultados satisfatórios para o paciente.


Assuntos
Humanos , Masculino , Feminino , Estética Dentária , Cirurgia Bucal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA