Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. chil. infectol ; 37(5): 523-530, nov. 2020. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1144246

RESUMO

Resumen Introducción: Las infecciones del tracto urinario (ITU) presentan una elevada prevalencia en el ámbito comunitario. Un rápido diagnóstico microbiológico es esencial para asegurar una terapia adecuada y efectiva. Objetivo: Evaluar un kit de antibiograma rápido (KAR®) en formato point-of-care para la detección rápida de ITU y sensibilidad antimicrobiana. Material y Métodos: El dispositivo KAR® se diseñó y desarrolló en colaboración con ingenieros técnicos y microbiólogos clínicos. Su evaluación se realizó a través de un estudio multicéntrico en el que participaron tres hospitales españoles. Para ello, se realizaron distintos ensayos in vivo con el fin de determinar la correlación del dispositivo con las técnicas microbiológicas de referencia. Resultados: Se ensayó un total de 400 muestras de orinas procedentes de pacientes con sospecha de ITU. El dispositivo KAR® proporcionó rápidos resultados (tiempo medio de positividad de 7,8 ± 1,5 h) con 97% de sensibilidad, 89% de especificidad y 87% de concordancia para la detección de bacteriuria significativa. Los porcentajes de especificidad para los antimicrobianos testados fueron: ciprofloxacina (97%), fosfomicina (94%), cotrimoxazol (84%), ampicilina (80%) y amoxicilina/ácido clavulánico (55%). Conclusión: El dispositivo KAR® puede ser una herramienta útil para el diagnóstico de ITU en pacientes ambulatorios, especialmente en áreas de bajo nivel socio-económico.


Abstract Background: Urinary tract infections (UTI) presents a high prevalence in the community setting. Rapid and accurate microbiological diagnosis is essential to ensure adequate and effective therapy. Aim: To evaluate a rapid antibiogram kit (KAR®) in point-of-care format for rapid detection of UTI and antibiotic susceptibility. Methods: The KAR® device has been designed and developed in collaboration with technical engineers and clinical microbiologists. Its evaluation has been carried out through a multicenter study in which three Spanish hospitals have participated. Thus, different in vivo tests have been implemented in order to determine device correlation with the reference microbiological techniques. Results: During the study period, a total of 400 urine samples from patients with suspected ITU were tested. The KAR® device provided fast results (mean positivity time of 7,8 ± 1,5 hours) with 97% sensitivity, 89% specificity and 87% agreement for the detection of significant bacteriuria. The percentages of specificity for the antibiotics tested were: ciprofloxacin (97%), fosfomycin (94%),cotrimoxazole (84%), ampicillin (80%) and amoxicillin/clavulanic acid (55%). Conclusion: The KAR® device could be a useful tool for diagnosing UTI in outpatients, especially in areas of low socio-economic level.


Assuntos
Humanos , Infecções Urinárias/diagnóstico , Infecções Urinárias/tratamento farmacológico , Sistemas Automatizados de Assistência Junto ao Leito , Testes de Sensibilidade Microbiana , Prevalência , Antibacterianos/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA