Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Braz. oral res. (Online) ; 32: e102, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974459

RESUMO

Abstract The aim of this study was to evaluate the effect of ethanol on the bond longevity of a universal adhesive system to bovine dentin, under different modes of adhesive application and artificial aging. Bovine dentin was exposed, and the smear layer was standardized by sandpaper polishing. Specimens were randomly divided into 2 groups: ethanol (E) and non-ethanol (N). Groups were subdivided according to adhesive mode of application into etch-and-rinse (Er) and self-etching (S). Resin blocks were built onto the treated surface, and the specimens were stored in deionized water at 37°C for 48 h. Half of the specimens (n = 10) were subjected to thermomechanical aging (A for aged and Na for non-aged). Resin/dentin beams were obtained and subjected to microtensile test in a universal testing machine. Data were analyzed using a three-way ANOVA and Tukey's tests (α = 5%). There was interaction among the three factors (p=0.0003). The use of ethanol resulted in higher values, except for the Er and Na groups (E_Er_Na = N_Er_Na). The mode of application was similar, except for the N and A groups (N_S_A > N_Er_A). For the A groups, the values were lower, except in the cases using ethanol, in which the results were not affected. The study concluded that the use of ethanol resulted in higher microtensile bond strength values, even after aging. The mode of adhesive application did not influence the results.


Assuntos
Animais , Bovinos , Colagem Dentária/métodos , Adesivos Dentinários/análise , Cimentos de Resina/química , Dentina/efeitos dos fármacos , Dentina/química , Etanol/química , Valores de Referência , Propriedades de Superfície , Temperatura , Resistência à Tração , Fatores de Tempo , Condicionamento Ácido do Dente/métodos , Teste de Materiais , Reprodutibilidade dos Testes , Colágeno/química , Camada de Esfregaço
2.
Braz. dent. sci ; 18(3): 98-106, 2015. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: lil-772993

RESUMO

Muitos sistemas adesivos foram desenvolvidos na última década. O objetivo desse estudo foi avaliara resistência adesiva ao cisalhamaneto (RAC)de bráquetes ortodônticos aderidos com primer convencional (PC) ou primer auto-condicionante (PAC), submetidos à ciclagem térmica (CT) e ciclagem térmico-mecânica (CTM). Incisivos bovinos (n =90)foram randomicamente divididos em 2 grupos (n =45) para a colagem dos bráquetes: XT (Transbond XT, 3M-Unitek, CA, USA); SEP (Transbond Plus SEP,3M-Unitek, CA, USA). Após o procedimento adesivo os grupos forma subdivididos em 3 sub-grupos: SC(sem ciclagem) – 1 e 4 (n =15 cada); CTM (ciclagem térmico-mecânica)- 2 e 5 (n = 15 cada); CT (ciclagem térmica)- 3 e 6 (n = 15 cada). Um simulador de fadiga térmica foi usado para os subgrupos 3 e 6, que fioram submetidos a 500 ciclos térmicos entre 5 and 55 C (ISO 11405). Os subgrupos 2 e 5 foram submetidos à ciclagem térmico-mecânica em um simulador de fadiga. Os espécimes foram colocados em uma basede metal num ângulo de 45 e os braquetes receberam impulsos de 1 bar e 4 Hz de frequência, por uma agulha de metal de 2.5 mm de diâmetro fixada na haste superior do equipamento. Foram submetidos a 100.000 ciclos mecânicos e 500 ciclos térmicos entre 5 and 55 C. O teste de RAC foi realizado emuma máquina universal de testes (1mm/min). Após orompimento da união foi realizada uma avaliação emmicroscopia óptica para avaliar a penetração adesivae o Índice de Permanência do Adesivo (IPA) sobreo esmalte. Os resultados mostraram maiores valores de RAC (14,70 ± 4,85 MPa) para o SEP. A CT não influenciou os resultados para o XT (NC- 11,44 MPa;TC - 11,20 MPa; TMC - 11,19 MPa), enquanto para oSEP, a CTM mostrou maiores valores (16,84 MPa)...


Several adhesive systems have been developed in the last decade. The aim of the current studywas to evaluate the shear bond strength (SBS) of orthodontic brackets bonded with conventional primers (XT) or self-etching primers (SEP), by means of thermocycling (TC) and thermomechanical(TM) procedures. 90 bovine incisors were randomly divided into 2 groups (45 specimens each) for brackets bonding: XT (Transbond XT, 3M-Unitek,CA, USA); SEP (Transbond Plus SEP, 3M-Unitek,CA, USA). After bonding, groups were divided into 3subgroups: NC (no cycling)- 1 and 4 (n = 15 each),TMC – 2 and 5 (n =15 each); and TC- 3 and 6 (n=15 each). The fatigue simulator was used for thethermal fatigue test of groups 3 and 6, which were submitted to thermal variation cycles - 500 cyles were carried out in between 5 and 55 C ( ISO 11405). Groups 2 and 5 were submitted to thermomechanicaltests by using the mechanical fatigue simulator. Thespecimens were placed at a metal base at an angleof 45, in a way that the 2.5 mm diameter metalneedle was fixed in the upper part of the cyclingmachine and could induce impulses of 1 bar loadintensity and 4 Hz frequency (4 cycles per second)on the bracket. The samples were submitted to 100000 mechanical cycles and 500 thermal cycles which varied from 5C to 55C. The SBS test was performed in a universal testing machine (1 mm/min). Afterdebonding, optic microscopic evaluation for adhesive penetration and Adhesive Remaining Index (ARI)analyses in the enamel surface were performed.The results showed higher SBS (14.70 ± 4.85 MPa)values for SEP. The SBS remained similar despitecycling (NC-11.44 MPa; TC-11.20 MPa; TMC-11.19MPa) for XT, meanwhile for SEP, ...


Assuntos
Bovinos , Braquetes Ortodônticos , Resistência ao Cisalhamento , Teste de Materiais
3.
Braz. dent. sci ; 16(4): 34-40, 2013. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: lil-728097

RESUMO

Objective: The aim of this study was to evaluate the cuspal deflection of teeth restored directly and indirectly. Material and Methods: Forty sound maxillary premolar teeth were restored with composite and different base materials. Wide mesial-occlusal-distal cavity preparations were performed, with isthmus width of one third of the distance between the cuspal tips, 3 mm occlusal and a 5 mm interproximal preparation height. The teeth were divided into 4 groups (n = 10), according to the restoration type: G1) GIC-DCR (1 mm glass ionomer cement base and direct restoration using nanoparticulate composite); G2) FL-DCR (1 mm base of flowable composite resin and direct restoration using nanoparticulate composite); G3) GIC-ICR (1 mm glass ionomer cement base and indirect restoration using nanoparticulate composite GIC base); G4) FL-ICR (1 mm base of flowable composite resin and indirect restoration using nanoparticulate composite). The specimens were submitted to compressive load of 50 N on the buccal and lingual cusps, in a universal testing machine. The lingual cusp microstrain (με) measurements were executed by strain gauges. Results: The Kruskal-Wallis (5%) test was used and showed there were no significant differences among the microstrain values for the four study groups (G1 = 1250; G2 = 1075; G3 = 1279; G4 = 937). Conclusion: It could be concluded that the restorative techniques and the bases employed did not show any influences in cuspal deflection


Objetivo: O objetivo deste trabalho foi avaliar, por meio de medidores de tensão, a deflexão cuspídea sofrida por dentes restaurados, direta e indiretamente, com resinas compostas e diferentes materiais de base. Material e Métodos: Para o preparo dos corpos-de-prova (CP) foram utilizados 28 dentes pré-molares humanos íntegros, extraídos por razões ortodônticas que tiveram suas raízes embutidas em poliuretano de densidade semelhante a do osso e suas raízes recobertas por um espaçador visando simular o espaço referente ao ligamento periodontal. Na etapa seguinte os dentes receberam preparos cavitários do tipo mésio-ocluso-distais amplos e então restaurados direta e indiretamente com resina composta e dois diferentes materiais de base/forramento, resina flow e cimento de ionômero de vidro. Para a realização das medidas de deflexão das cúspides foram utilizados extensômetros lineares elétricos colados à face lingual de cada dente e submetidos a uma carga de 50 N aplicada por uma ponta romba de diâmetro de 3,0 mm, que promoveu compressão simultânea nas vertentes triturantes das cúspides vestibular e lingual, numa máquina universal de ensaios. Resultados: Foi realizado o teste de Kruskall-Wallis (5%) de significância e não foram encontradas diferenças estatísticamente significantes entre os grupos (G1 – 1250; G2 = 1075; G3 = 1279; G4 = 937). Conclusão: Pode-se concluir que o tipo de restauração bem como o tipo de base empregados nesse estudo não alteram a deflexão cuspídea dos dentes com restaurações amplas.


Assuntos
Humanos , Resinas Compostas , Cimentos de Ionômeros de Vidro
4.
Braz. dent. j ; 23(4): 373-378, 2012. tab
Artigo em Inglês | LILACS | ID: lil-658013

RESUMO

The aim of this study was to investigate the effects of some acidic drinks on dentin erosion, using methods of surface profile (SP) analysis and energy-dispersive X-ray fluorescence spectrometry (EDXRF). One hundred standardized dentin slabs obtained from bovine incisor roots were used. Dentin slabs measuring 5x5 mm were ground flat, polished and half of each specimen surface was protected with nail polish. For 60 min, the dentin surfaces were immersed in 50 mL of 5 different drinks (Gatorade®, Del Valle Mais orange juice®, Coca-Cola®, Red Bull® and white wine), 20 blocks in each drink. The pH of each beverage was measured. After the erosive challenge, the nail polish was removed and SP was analyzed. The mineral concentration of dentin surfaces was determined by means of EDXRF. Data were analyzed statistically by ANOVA and Tukey's test (α=0.05). SP analysis showed that Red-Bull had the highest erosive potential (p<0.05). EDXRF results exhibited a decrease in phosphate in the groups immersed in Red-Bull, orange juice and white wine (p<0.05), and no significant difference in calcium content between the reference surface and eroded surface. In conclusion, this study demonstrated that all studied beverages promoted erosion on root dentin and Red Bull had the highest erosive potential. There was no correlation between pH of beverages and their erosive potential and only the P content changed after erosive challenge.


O objetivo deste estudo foi investigar os efeitos de algumas bebidas ácidas sobre a erosão da dentina, utilizando métodos de análise de perfil de superfície (SP) e espectrometria de energia dispersiva de fluorescência de raios X (EDXRF). Cem blocos de dentina padronizados obtidos de raízes de incisivos bovinos foram utilizados. Os blocos de dentina medindo 5x5 mm foram planificados, polidos e metade de cada superfície das amostras foram impermeabilizados com esmalte para unhas. Por 60 min, as superfícies de dentina foram imersas em 50 mL de 5 bebidas diferentes (Gatorade, suco de laranja, Coca-Cola, Red Bull e vinho branco), 20 blocos em cada bebida. O pH de cada bebida foi medido. Após o desafio erosivo, o esmalte de unha foi removido e SP foram analisados. A concentração de minerais das superfícies de dentina foi determinada por meio de EDXRF. Os dados foram analisados estatisticamente por ANOVA e teste de Tukey. (p<0,05). A análise SP mostrou que o Red-Bull apresentou o maior potencial erosivo. Os resultados do EDXRF apresentaram uma diminuição do fosfato dos grupos imersos no Red-Bull, suco de laranja e vinho branco, e não houve diferença significativa no teor de cálcio entre a superfície de referência e a superfície que sofreu erosão. O Red Bull apresentou o maior potencial erosivo sobre a dentina radicular. Não houve correlação entre o pH das bebidas e o seu potencial erosivo.


Assuntos
Animais , Bovinos , Bebidas/efeitos adversos , Dentina/patologia , Erosão Dentária/etiologia , Ácidos , Citrus sinensis , Cálcio/análise , Bebidas Gaseificadas/efeitos adversos , Bebidas Energéticas/efeitos adversos , Dureza , Concentração de Íons de Hidrogênio , Fosfatos/análise , Espectrometria por Raios X , Fatores de Tempo , Vinho/efeitos adversos
5.
Braz. oral res ; 24(1): 64-69, Jan.-Mar. 2010. tab
Artigo em Inglês | LILACS | ID: lil-541515

RESUMO

The aim of this in vitro study was to compare the photoactivation effects of QTH (Quartz-Tungsten-Halogen) and LED (Light-Emitting Diode) on the SBS (Shear Bond Strength) of orthodontic brackets at different debond times. Seventy-two bovine lower incisors were randomly divided into two groups according to the photoactivation system used (QTH or LED). The enamel surfaces were conditioned with Transbond self-etching primer, and APC (Adhesive Pre-Coated) brackets were used in all specimens. Group I was cured with QTH for 20 s and Group II with LED for 10 s. Both groups were subdivided according to the different experimental times after bonding (immediately, 24 h and 7 days). The specimens were tested for SBS and the enamel surfaces were analyzed according to the Adhesive Remnant Index (ARI). The statistical analysis included the Tukey's test to evaluate the main effects of photoactivation and debond time on SBS. The Chi-square test was used to compare the ARI values found for each group, and no statistically significant difference was observed. The debond time of 7 days for QTH photoactivation showed statistically greater values of SBS when compared to the immediate and 24 h periods. There was no statistically significant difference between the QTH and LED groups immediately and after the 24 h period. In conclusion, bonding orthodontic brackets with LED photoactivation for 10 s is suggested because it requires a reduced clinical chair time.


Assuntos
Animais , Bovinos , Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários/métodos , Braquetes Ortodônticos , Resistência ao Cisalhamento/efeitos da radiação , Condicionamento Ácido do Dente , Descolagem Dentária , Teste de Materiais , Cimentos de Resina/efeitos da radiação , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo
6.
Braz. oral res ; 23(4): 439-445, Oct.-Dec. 2009. graf, tab
Artigo em Inglês | LILACS | ID: lil-534216

RESUMO

The aim of this study was to assess the microhardness of 5 glass ionomer cements (GIC) - Vidrion R (V, SS White), Fuji IX (F, GC Corp.), Magic Glass ART (MG, Vigodent), Maxxion R (MR, FGM) and ChemFlex (CF, Dentsply) - in the presence or absence of a surface protection treatment, and after different storage periods. For each GIC, 36 test specimens were made, divided into 3 groups according to the surface protection treatment applied - no protection, varnish or nail varnish. The specimens were stored in distilled water for 24 h, 7 and 30 days and the microhardness tests were performed at these times. The data obtained were submitted to the ANOVA for repeated measures and Tukey tests (á = 5 percent). The results revealed that the mean microhardness values of the GICs were, in decreasing order, as follows: F > CF = MR > MG > V; that surface protection was significant for MR, at 24 h, without protection (64.2 ± 3.6a), protected with GIC varnish (59.6 ± 3.4b) and protected with nail varnish (62.7 ± 2.8ab); for F, at 7 days, without protection (97.8 ± 3.7ab), protected with varnish (95.9 ± 3.2b) and protected with nail varnish (100.8 ± 3.4a); and at 30 days, for F, without protection (98.8 ± 2.6b), protected with varnish (103.3 ± 4.4a) and protected with nail varnish (101 ± 4.1ab) and, for V, without protection (46 ± 1.3b), protected with varnish (49.6 ± 1.7ab) and protected with nail varnish (51.1 ± 2.6a). The increase in storage time produced an increase in microhardness. It was concluded that the different GICs, surface protection treatments and storage times could alter the microhardness values.


Assuntos
Tratamento Dentário Restaurador sem Trauma/métodos , Forramento da Cavidade Dentária/instrumentação , Cimentos de Ionômeros de Vidro/química , Análise de Variância , Tratamento Dentário Restaurador sem Trauma/instrumentação , Armazenamento de Medicamentos/métodos , Testes de Dureza , Teste de Materiais , Propriedades de Superfície , Fatores de Tempo
7.
Ciênc. odontol. bras ; 11(3): 32-37, jul.-set. 2008. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-524141

RESUMO

O objetivo deste estudo in vitro foi avaliar o selamento de restaurações de resina composta e cimento de ionômero de vidro modificado por resina em cavidades de classe V de dentes bovinos diante das seguintes variáveis: preparo cavitário com turbina de alta rotação e preparo cavitário com laser de Er:YAG. Para tanto, foram selecionados 60 dentes bovinos hígidos, provenientes de animais com idade média de três anos. Metade dos espécimes (n=30) foi preparada com turbina de alta rotação e a outra metade (n=30) com laser de Er:YAG. Dos dentes preparados com turbina de alta rotação, metadeda amostra (n=15) foi restaurada com resina composta e o restante restaurado com CIV modificado por resina, ambosde acordo com as instruções do fabricante. O mesmo procedimento foi realizado com os dentes que foram preparados com laser de Er:YAG. Os dentes foram submetidos à metodologia de microinfiltração marginal, empregando como corante a solução aquosa de nitrato de prata. Cada dente foi seccionado em três fatias no sentido vestíbulo-lingual. As fatias foram coladas em lâmina de vidro e devidamente identificadas, para avaliação e mensuração do grau de infiltração marginal em estereomicroscópio- Karl Zeiss com auxílio do programa Image Tool- 3.0. Os resultados revelaram queindependentemente do material empregado, os dentes preparados com laser de Er:YAG apresentaram menores valores para microinfiltração marginal, sendo estes valores estatisticamente significantes.


Assuntos
Animais , Bovinos , Cimentos de Ionômeros de Vidro , Equipamentos Odontológicos de Alta Rotação , Lasers , Preparo da Cavidade Dentária , Resinas Compostas
8.
J. appl. oral sci ; 15(5): 459-464, Sept.-Oct. 2007. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-465931

RESUMO

The aim of this in vitro study was to evaluate the effect of different bur types and acid etching protocols on the shear bond strength (SBS) of a resin modified glass ionomer cement (RM-GIC) to primary dentin. Forty-eight clinically sound human primary molars were selected and randomly assigned to four groups (n=12). In G1, the lingual surface of the teeth was cut with a carbide bur until a 2.0-mm-diameter dentin area was exposed, followed by the application of RM-GIC (Vitremer - 3M/ESPE) prepared according to the manufacturer's instructions. The specimens of G2, received the same treatment of G1, however the dentin was conditioned with phosphoric acid. In groups G3 and G4 the same procedures of G1 and G2 were conducted respectively, nevertheless dentin cutting was made with a diamond bur. The specimens were stored in distilled water at 37ºC for 24h, and then tested in a universal testing machine. SBS. data were submitted to 2-way ANOVA (= 5 percent) and indicated that SBS values of RM-GIC bonded to primary dentin cut with different burs were not statistically different, but the specimens that were conditioned with phosphoric acid presented SBS values significantly higher that those without conditioning. To observe micromorphologic characteristics of the effects of dentin surface cut by diamond or carbide rotary instruments and conditioners treatment, some specimens were examined by scanning electron microscopy. Smear layer was present in all specimens regardless of the type of rotary instrument used for dentin cutting, and specimens etched with phosphoric acid presented more effective removal of smear layer. It was concluded that SBS of a RM-GIC to primary dentin was affected by the acid conditioning but the bur type had no influence.

9.
São José dos Campos; s.n; 2007. 129 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: lil-494859

RESUMO

O objetivo deste estudo in vitro foi comparar os efeitos da fotoativação pelos sistemas luz halógena e LED na adesão de braquetes ortodônticos em diferentes tempos pós-colagem (imediato, 24h e 7d). Braquetes com adesivo pré-aplicado (Gemini series; APC adhesive precoated brackets; 3M Unitek, USA) foram colados na superfície vestibular de dentes bovinos. O esmalte dos dentes foi condicionadoutilizando-se o primer auto-condicionante (Transbond SEP, 3M Unitek, USA) em todos os espécimes, conforme recomendações do fabricante. Setenta e dois dentes foram divididos em 2 grupos (n=36), conforme o sistema de fotoativação (luzhalógena ou LED) e sub-divididos (n=12) de acordo com o tempo pós-colagem. Para os grupos luz halógena, o tempo de fotoativação foi de 20s e para os grupos LED foi de 10s. O teste de resistência ao cisalhamento foi realizado com auxílio de uma máquina de ensaios universal nos diferentes tempos pós-colagem: imediato, 24h e 7d. O valor médio de adesão para os grupos luz halógena foi de 20,01±5,24MPa e, para os grupos fotoativados pelo sistema LED 17,35±5,07MPa, sendo estes resultados estatisticamente diferentes. Quando comparado o efeito do tempo pós-colagem, os resultados revelaram que os valores de adesão foramsignificantemente maiores para o tempo de 7d. O resultado do teste ANOVA 2 –fatores revelou não existir diferença estatística entre a interação sistema defotoativação e tempos pós-colagem. O teste de Tukey mostrou que para as 4condições experimentais nos tempos imediato e 24h, os resultados não diferiram estatisticamente, independentemente do sistema de fotoativação...


Assuntos
Bovinos , Adesivos Dentinários , Luz/efeitos adversos , Braquetes Ortodônticos , Resistência ao Cisalhamento
10.
Pesqui. bras. odontopediatria clín. integr ; 6(3): 323-328, set.-dez. 2006. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-455400

RESUMO

Objetivo: Avaliar a eficiência do uso de laser de diodo(Diagnodent 2095®, Kavo/Alemanha) no diagnóstico de lesõesde cáries oclusais comparando-o com o método visual.Método: A amostra foi composta por 39 dentes permanentes(18 molares e 21 pré-molares), que apresentavam alteraçãomacroscópica visível, podendo indicar lesão de cárie inicial,num total de 60 sítios. Dois examinadores fizeram asavaliações separadamente (visual e laser). O diagnósticovisual foi feito com a utilização de espelho bucal e luz artificial,sem sonda exploradora. Para o diagnóstico com Diagnodentforam realizadas 3 medições para cada sítio, obtendo-se umamédia. Foram excluídos os sítios classificados como hígidos, eos sítios classificados como cariados foram selecionados paraa comprovação dos métodos diagnósticos, através detratamento invasivo. Em seguida, verificou-se a real situaçãodo comprometimento tecidual através de inspeção visual porambos os examinadores. Para o cálculo do erro intraexaminadorese inter-examinadores para cada sistemadiagnóstico utilizou-se o método estatístico de kappa. O índicede concordância entre examinadores foi de k=0,82 para ométodo visual e k=0,93 para o diagnóstico com Diagnodent. Acorrespondência entre os dois métodos de diagnóstico foik=0,70 para o examinador 1 e k= 0,77 para o examinador 2. Osvalores de sensibilidade e especificidade foram calculados combase nos dados obtidos após o tratamento invasivo.Resultados: No exame visual a especificidade foi de 59,5 por cento e asensibilidade foi 88,9 por cento, enquanto com o método Diagnodent foide 69,1 por cento e 100 por cento respectivamente. Conclusão: O diagnósticocom Diagnodent é efetivo para identificação de cáries oclusaisincipientes quando comparado com o método visual, podendoser utilizado como um método auxiliar.


Assuntos
Humanos , Adolescente , Adulto , Cárie Dentária/diagnóstico , Lasers , Oclusão Dentária
11.
Ciênc. odontol. bras ; 6(4): 17-24, out.-dez. 2003. ilus, tab
Artigo em Inglês, Português | LILACS, BBO | ID: lil-385924

RESUMO

A hipersensibilidade dentinária é uma patologia que afeta individuos de ambos os sexos, caracterizando-se por uma resposta exagerada a um estímulo que normalmente não causaria dor em um dente sadio. A etiologia é multifatorial, sendo que a dor se instala principalmente quando a dentina localizada na região cervical do dente fica exposta ao meio bucal. Este trabalho teve como objetibo testar a eficácia da aplicação do laser diodo de arseneto de gálio alumínio (GaAIAs) no tratamento da hipersensibilidade dentinária. Foram selecionados cinqüenta dentes de pacientes da Faculdade de Odontologia de São José dos Campos - UNESP que apresentavam hipersensibilidade dentinária. Este trabalho foi aprovado pelo Comitê de Ética local.Os pacientes foram questionados sobre a dor e, após estímulo táctil (sonda exploradora) e estímulo evaporativo (jato de ar), atribuíam escores, que eram anotados em uma escala visual análoga: escore 10 (dor intolerável), 7 a 9 (dor forte e tolerável), 4 a 6 (dor moderada), 1 a 3 (dor leve) e 0 (ausência de dor). A aplicação do laser foi realizada na superfície que apresentava sensibilidade (não-contato) durante 2 minutos a 15 mW de potência. Os escores foram atribuídos antes e após cada aplicação. Foram realizadas no máximo 3 aplicações, com intervalo de 7 dias. Os resultados foram analisados pela Análise de Variância. Não Paramétrica de Friedman (p<0,001) e Comparação Múltipla de Tukey (p<0,05). A porcentagem de dentes que apresentou ausência de dor ao teste evaporativo passou de 2 porcento (inicio) para 62 porcento (final do tratamento) e, ao teste táctil, de 46 porcento para 86 porcento, estatisticamente significante. Concluiu-se que o tratamento realizado foi efetivo na reduçáo da hipersensibilidade dentinária.


Assuntos
Sensibilidade da Dentina , Lasers
12.
Ciênc. odontol. bras ; 5(3): 46-53, set.-dez. 2002. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-407979

RESUMO

Um dos principais objetivos da Odontopediatria moderna é a prevenção e a manutenção da saúde dos pacientes infantis, que apresentam contínuo crescimento e desenvolvimento. Qualquer desvio da normalidade da arcada dentária poderá acarretar problemas, quando não detectados e tratados precocemente. Long, em 1999, desenvolveu gabaritos da forma dos arcos decíduos do tipo I e II de Baume, através da computação eletrônica, para análise morfológica da dentadura decídua, por sobreposição em modelos de gesso. Este estudo testou estes gabaritos desenvolvidos por Long em 30 pares de modelos de gesso com de pacientes da clínica de odontopediatria da Faculdade de Odontologia da UNESP-SJC, com dentadura decídua completa. Alguns destes pacientes tinham maloclusão, outros oclusão normal. Foi, então, analisado o posicionamento vestíbulo-lingual de cada um dos dentes das arcadas superior e inferior. Observou-se que 60 por cento dos dentes analisados na maxila estavam vestibularizados em relação à posição ideal, enquanto que na mandíbula, 50 por cento dos dentes tinham um bom posicionamento. Desta forma, concluiu-se que, os gabaritos são de simples aplicação clínica, inclusive para o clínico geral, podendo ser muito útil na determinação precoce de problemas na dentadura decídua


Assuntos
Decídua , Oclusão Dentária , Dentaduras
13.
Ortodontia ; 35(2): 35-39, abr.-jun. 2002. tab, graf
Artigo em Português | LILACS | ID: lil-318517

RESUMO

O objetivo deste estudo foi de avaliar, numa amostra longitudinal composta de 90 pacientes, o desenvolvimento da sobressaliência durante três períodos distintos de desenvolvimento. Desta forma, 180 modelos de estudo superiores e inferiores foram analisados durante os períodos das dentaduras decídua, mista e permanente, totalizando 540 modelos. Os modelos foram selecionados do acervo da The University of Michigan Elementary and Growth Studies (UMGS). Nenhum dos pacientes foi submetido a qualquer tipo de tratamento ortodôntico. Os resultados revelaram que a sobressaleência teve um aumento discreto no período compreendido entre as dentaduras mista e permanente, apresentando um valor médio de 2,18 mm na dentadura decídua, 3,05 mm na dentadura mista e 3,38 mm na dentadura permanente


Assuntos
Humanos , Masculino , Feminino , Dentição Mista , Dentição Permanente , Dente Decíduo
14.
RFO UPF ; 6(2): 29-32, jul.-dez. 2001. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-308354

RESUMO

O objetivo deste trabalho foi avaliar a existência de uma correlaçäo entre a presença ou ausência de sintomatologia e o aspecto histopatológico pulpar em dentes decíduos cariados. Foram selecionados quarenta molares decíduos cariados de crianças com idades entre cinco e oito anos, nos quais foi avaliado o aspecto histológico pulpar de acordo com sua sintomatologia dolorosa. O tipo de cárie também foi relacionado com os sintomas clíncios. O diagnóstico histológico foi classificado em reaçäo inflamatória aguda ou crônica. Os resultados mostraram que a reaçäo inflamatória aguda foi associada com a presença de sintomatologia, ao passo que uma reaçäo inflamtória crônica foi associada com ausência de sintomatologia (Teste de Fisher, p = 0,000). Lesöes de Cárie do tipo agudo foram relacionadas com reaçäo pulpar do tipo agudo, e lesöes crônicas, com reação pulpar crônica (Teste de Fisher, p= 0,031). Dentina reparadora foi observada em 94 por cento de amostra, indicando que os dentes decíduos reagem ao ataque da doença cárie, embora sua presença näo possa prevenir que agentes irritantes alcancem o tecido pulpar. A presença ou ausência de sintomatologia pode ser um bom indicador do aspecto histológico pulpar


Assuntos
Masculino , Feminino , Criança , Cárie Dentária , Dente Molar , Polpa Dentária/fisiopatologia , Sinais e Sintomas , Dente Decíduo
15.
J. bras. ortodon. ortop. facial ; 6(33): 249-255, maio-jun. 2001. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-307004

RESUMO

O objetivo deste estudo foi o de avaliar, numa amostra longitudinal composta de 90 pacientes, o desenvolvimento da relaçäo molar durante três períodos distintos de desenvolvimento. Desta forma 180 modelos de estudos superiores e inferiores foram analisados durante os períodos das dentiçöes decídua, mista e permanente, totalizando 540 modelos. Os modelos foram selecionados do acervo da University of Michigan Elementary and Growth Studies (UMGS). Nenhum dos pacientes foi submetido a qualquer tipo de tratamento ortodôntico. Os resultados revelaram que a relaçäo mais freqüente dos segundos molares decíduos foi de plano terminal reto, seguido dos casos de degrau mesial e degrau distal. A relaçäo Classe I de Angle foi a mais freqüente para os primeiros molares permanentes, tanto na dentiçäo mista como na permanente, independentemente da relaçäo dos segundos molares decíduos. A maioria dos casos que apresentavam uma relaçäo de degrau mesial e plano terminal reto, na dentiçäo decídua, evoluiu para uma relaçäo de Classe I de Angle, na fase de dentiçäo permanente


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adolescente , Adulto , Arco Dental , Oclusão Dentária , Dentição Mista , Dentição Permanente , Dente Decíduo , Diagnóstico Bucal , Estudos Longitudinais , Má Oclusão , Dente Molar
16.
J. bras. ortodon. ortop. facial ; 6(31): 31-34, jan.-fev. 2001. tab
Artigo em Português | LILACS, BBO | ID: lil-336369

RESUMO

O objetivo deste estudo foi de avaliar, numa amostra longitudinal composta de 90 pacientes, o desenvolvimento da sobremordida durante três períodos distintos de desenvolvimento. Desta forma, 180 modelos de estudo superiores e inferiores foram analisados durante os períodos das dentiçöes decídua, mista e permanente, totalizando 540 modelos. Os modelos foram selecionados do acervo da The University of Michigan Elementary and Secondary Growth Studies (UMGS). Nenhum dos pacientes foi submetido a qualquer tipo de tratamento ortodôntico. Os resultados revelaram que a sobremordida aumentou da dentiçäo mista para a permanente, e os valores médios obtidos foram de 1,42 mm, 2,31 mm e 3,1 mm para as dentiçöes decídua, mista e permanente, respectivamente


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adulto , Má Oclusão/epidemiologia , Dentição Mista , Dentição Permanente , Estudos Longitudinais , Dente Decíduo
17.
Säo Paulo; s.n; 1998. 93 p. ilus, tab.
Tese em Português | LILACS, BBO | ID: lil-211231

RESUMO

O objetivo deste estudo foi de avaliar, numa amostra longitudinal composta de 90 pacientes, o desenvolvimento da relaçäo molar e relaçäo canina, além da sobremordida, sobressaliência e linha média durante três períodos distintos de desenvolvimento. Desta forma, 180 modelos de estudo superiores e inferiores foram analisados durante os períodos das dentiçöes decídua, mista e permanente, totalizando 540 modelos. Os modelos foram selecionados do acervo da The University of Michigan Elementary and Growth Studies (UMGS). Nenhum dos pacientes foi submetido a qualquer tipo de tratamento ortodôntico. Os resultados revelaram que a relaçäo mais frequente dos segundos molares decíduos foi de plano terminal reto, seguido dos casos de degrau mesial e degrau distal...


Assuntos
Arco Dental/anatomia & histologia , Arco Dental/fisiologia , Oclusão Dentária , Dentição Mista , Dentição Permanente , Dente Decíduo , Diagnóstico Bucal , Má Oclusão
18.
Rev. bras. odontol ; 54(3): 163-6, maio-jun. 1997.
Artigo em Português | LILACS, BBO | ID: lil-197414

RESUMO

O presente trabalho teve por objetivo relatar os meios e métodos da utilizaçäo segura de fluoretos na prática odontológica visando a prevençäo e controle da cárie dentária no paciente infantil


Assuntos
Humanos , Masculino , Feminino , Criança , Cárie Dentária/prevenção & controle , Resinas Compostas , Amálgama Dentário , Dentifrícios , Fluoretos Tópicos , Fluoretos/toxicidade , Cimentos de Ionômeros de Vidro , Odontopediatria/tendências , Halogenação , Antissépticos Bucais
19.
Rev. ABO nac ; 3(6): 382-4, dez. 1995-jan. 1996. ilus
Artigo em Português | LILACS, BBO | ID: lil-203097

RESUMO

A gengivo-estomatite herpética primária é uma doença infecto-contagiosa causada pelo vírus herpes simples, de ocorrência relativamente freqüente em crianças dentro da primeira década de vida. Revisou-se os aspectos relativos à epidemiologia, clínica e tratamento da doença, buscando subsidiar principalmente os odontopediatras, uma vez que os sintomas bucais säo preponderantes, levando os responsáveis pela criança a procurarem primordialmente os dentistas, que devem estar preparados tanto para o diagnóstico como para a orientaçäo terapêutica destes casos


Assuntos
Humanos , Criança , Pré-Escolar , Estomatite Herpética/diagnóstico , Estomatite Herpética/terapia , Odontopediatria , Herpes Labial/diagnóstico , Herpes Labial/etiologia
20.
Rev. odontopediatr ; 1(2): 117-23, abr.-jun. 1992. ilus
Artigo em Português | LILACS, BBO | ID: lil-211034

RESUMO

O presente trabalho relata um caso clínico de amelogênese imperfeita do tipo hipoplástica, onde a estética foi bastante comprometida. O tratamento reabilitador baseou-se na reconstruçäo dos molares decíduos e permanentes com resina para dentes posteriores pela técnica in lay/on lay e para os dentes anteriores foram confeccionadas facetas estéticas em resina com o auxílio de pigmentos


Assuntos
Criança , Amelogênese Imperfeita/diagnóstico , Amelogênese Imperfeita/terapia , Estética Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA