Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Peking University(Health Sciences) ; (6): 16-23, 2020.
Artigo em Chinês | WPRIM | ID: wpr-942136

RESUMO

OBJECTIVE@#To explore the association between the abnormal root morphology and bone metabolism or root development related gene polymorphism in patients with generalized aggressive periodontitis.@*METHODS@#In the study, 179 patients with generalized aggressive periodontitis were enrolled, with an average age of (27.23±5.19) years, male / female = 67/112. The average number of teeth remaining in the mouth was (26.80±1.84). Thirteen single nucleotide polymorphisms (SNPs) of nine genes which related to bone metabolism and root development were detected by matrix assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF-MS). Root abnormalities were identified using periapical radiographs. The abnormal root morphology included cone-rooted teeth, slender-root teeth, short-rooted teeth, curved-rooted teeth, syncretic-rooted molars, and molar root abnormalities. The number of teeth and incidence of abnormal root morphology in different genotypes of 13 SNPs were analyzed.@*RESULTS@#The constituent ratio of root with root abnormality in GAgP patients was 14.49%(695/4 798). The average number of teeth with abnormal root morphology in GAgP was (3.88±3.84). The average number of teeth with abnormal root morphology in CC, CT and TT genotypes in vitamin D receptor (VDR) rs2228570 was (4.66±4.10), (3.71±3.93) and (2.68±2.68). There was significant difference between TT genotype and CC genotype (t = 2.62, P =0.01). The average number of root morphological abnormalities in CC, CT and TT genotypes of Calcitotin Receptor (CTR) gene rs2283002 was (5.02±3.70), (3.43±3.95), and (3.05±3.12). The incidence of root morphological abnormalities in CC genotype was higher than that in the patients with CT and TT, and the difference was statistically significant(87.86% vs. 65.26% & 63.64%, P=0.006, adjusted OR =3.71, 95%CI: 1.45-9.50). There was no significant difference in the incidence of abnormal root morphology between CT and TT genotypes.@*CONCLUSION@#VDR rs2228570 and CTR rs2283002 may be associated with the occurrence of abnormal root morphology in patients with generalized aggressive periodontitis, which is worthy of further research.


Assuntos
Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Periodontite Agressiva/genética , Estudos de Casos e Controles , Frequência do Gene , Predisposição Genética para Doença , Genótipo , Polimorfismo de Nucleotídeo Único , Receptores de Calcitriol/genética
2.
Journal of Southern Medical University ; (12): 615-618, 2015.
Artigo em Chinês | WPRIM | ID: wpr-355315

RESUMO

<p><b>OBJECTIVE</b>To evaluate the effect of thermal cycling on surface microstructure of different light-curing composite resins.</p><p><b>METHODS</b>A nanofilled composite (Z350) and 4 microhybrid composites (P60, Z250, Spectrum, and AP-X) were fabricated from lateral to center to form cubic specimens. The lateral surfaces were abrased and polished before water storage and 40 000 thermal cycles (5/55 degrees celsius;). The mean surface roughness (Ra) were measured and compared before and after thermal cycling, and the changes of microstructure were observed under scanning electron microscope (SEM).</p><p><b>RESULTS</b>Significant decreases of Ra were observed in the composites, especially in Spectrum (from 0.164±0.024 µm to 0.140±0.017 µm, P<0.001) and Z250 (from 0.169±0.035 µm to 0.144±0.033 µm, P<0.001), whose Ra approximated that of P60 (0.121±0.028 µm) with smoothly polished surface. SEM revealed scratches and shallower pits on the surface of all the 5 resins, and fissures occurred on Z350 following the thermal cycling.</p><p><b>CONCLUSION</b>Water storage and thermal cycling may produce polishing effect on composite resins and cause fissures on nanofilled composite resins.</p>


Assuntos
Resinas Compostas , Polimento Dentário , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Propriedades de Superfície , Temperatura
3.
Practical Oncology Journal ; (6): 202-206, 2014.
Artigo em Chinês | WPRIM | ID: wpr-499225

RESUMO

Objective To study radiation -induced lung damage after lung ionizing radiation and the temporal and spatial release of pro -inflammatory cytokines of interleukin -6(IL-6),interleukin-8(IL-8) and interleukin-10(IL-10)in the irradiated lung tissue.Methods BALB/C male mice weighted around 25 g were randomly divided into two groups:radiation group ( R) and control group ( C) ,with 30 mice in R group and10 mice in C group.The thorax of mice was irradiated by 6 MV X-ray with 25 Gy in 5 fractions.The mice were sac-rificed at 12 weeks post irradiation.Lung tissues were collected and embedded in paraffin .After HE staining,lung histopathological changes were detected by immunohistochemistry to detect IL -6,IL-8 and IL-10 expression in lung tissue.Results Immunohistochemistry results showed that the expressions of IL -6,IL-8 and IL-10 were mainly expressed in macrophages and inflammatory cells .The results showed that the expressions of IL -6 and IL-8 in R group were significantly higher than that in C group .IL-10 expression level was lower than C group.Conclusion After 12 weeks exposing to radiation ,cytokines of IL-6,IL-8 and IL-10 in lung tissue are associated with radiation -induced lung injury .

4.
Journal of Southern Medical University ; (12): 727-730, 2014.
Artigo em Chinês | WPRIM | ID: wpr-249371

RESUMO

<p><b>OBJECTIVE</b>To compare the surface roughness of nanofilled dental composite resin and microhybrid composite resins after curing and polishing.</p><p><b>METHODS</b>A nanofilled composite (Z350) and 4 microhybrid composites (P60, Z250, Spectrum, and AP-X) were fabricated from the lateral to the medial layers to prepare 8 mm×8 mm×5 mm cubical specimens. The 4 lateral surfaces of each specimens were polished with abrasive disks (Super-Snap). Profilometer was used to test the mean surface roughness (Ra) after polishing.</p><p><b>RESULTS</b>P60 had the lowest Ra (0.125∓0.030 µm) followed by Z250 and Spectrum. The Ra of Z350 (0.205∓0.052 µm) was greater than that of the other 3 resins, and AP-X had the roughest surfaces. Under scanning electron microscope, the polished faces of P60 resin were characterized by minor, evenly distributed particles with fewer scratches; the polished faces of Z350 presented with scratches where defects of the filling material could be seen.</p><p><b>CONCLUSION</b>The nanofilled composite Z350 has smooth surface after polishing by abrasive disks, but its smoothness remains inferior to that of other micro-hybrid composite resins.</p>


Assuntos
Resinas Acrílicas , Resinas Compostas , Materiais Dentários , Polimento Dentário , Teste de Materiais , Poliuretanos , Propriedades de Superfície
5.
China Journal of Chinese Materia Medica ; (24): 2087-2089, 2008.
Artigo em Chinês | WPRIM | ID: wpr-252195

RESUMO

<p><b>OBJECTIVE</b>To reveal the relationship between the storage time of the bark of Magnolia officinalis and the content of phenols in it, and lay a theoretical foundation for the harvest, processing, management and storage.</p><p><b>METHOD</b>The contents of magnolol and honokoiol in 15 bark samples, collected from the main producing areas in China, were determined in the time of freshly harvest and 3 and 10 years after respectively by HPLC method.</p><p><b>RESULT</b>It showed that within a certain period of time, bark storage was favorable to conversion and accumulation of phenols, that the content of magnolol tended to increase from year 0 to year 3, then followed by slight decrease with years on account of volatilization of phenols, but was still higher when the bark was stored for 10 years than that that when the bark was freshly harvested, and the content of honokoiol still tended to increase when the bark had been stored for 10 years.</p><p><b>CONCLUSION</b>The phenols in bark of M. officinalis is quite stable and the bark can be stored for 10 years or longer.</p>


Assuntos
Compostos de Bifenilo , Armazenamento de Medicamentos , Métodos , Medicamentos de Ervas Chinesas , Química , Lignanas , Magnolia , Química , Casca de Planta , Química , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA