1.
Chinese Journal of Preventive Medicine ; (12): 1047-1058, 2023.
Artigo em Chinês | WPRIM | ID: wpr-985515

RESUMO

Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.


Assuntos
Gravidez , Criança , Humanos , Feminino , Hemoglobinas Glicadas , Estudos de Coortes , Diabetes Mellitus/diagnóstico , Sensibilidade e Especificidade , Curva ROC
2.
Journal of Experimental Hematology ; (6): 557-562, 2019.
Artigo em Chinês | WPRIM | ID: wpr-771920

RESUMO

OBJECTIVE@#To investigate the feasibilily of screening and identifying the red blood cell type alloantibodies by means of surface plasman resonance(SPR) technique so as to provide a new method for detecting the transfusion compatibility of red blood cells.@*METHODS@#The RBC antigens for screening the alloantibody were fixed on the SPR chip surface by means of amino coupling method; the analysis conditions of SPR chip were optimized and then the control serum with RBC blood group antibody positive was detected; the performance of SPR chip for detection of serum was analysed; the consistance of rusults detected by SPR technique and microcolum agglutination for clinieal samples of 129 thalasstmia patients with history of lone-term blood transfusion were compared; at the same time, the blood group amtibodies in 7 patients with blood group antibody positive were identified before blood transfusion by using SPR chip so as to select the RBC antigen compatible blood for transfusion; and the efficacy of RBC transfusion was followed up and evaluated.@*RESULTS@#The repeatability, sensitivity and specificity of SPR chip technique for detecting the blood group alloantibodies all were better. The SPR technique and microcolumn agglutination method were not significant different for screening blood group alloantibodies (χ2 = 0.333, P>0.05), and the overall consistency was 97.2%; the results of SPR technique in 7 patients with positive blood group antibodies were as follows: 3 cases with anti-E, 1 case anti-M, 1 case anti-C, 1 case anti-Jka and 1 case autoantibody, which were consistent with the results of microcolumn agglutination tests, and the compatible red blood cells were selected for transfusion, of which the infusion of 6 cases was effective. In only 1 case the infusion was ineffective because of autoantibody.@*CONCLUSION@#For screening and identification of blood group alloantibodies, the performance of SPR chip technique is equivalent to the micro-column agglutination, but the procedure of SPR technique is simpler, faster and high-throughput and label-free, which can meet the basic requirements for rapid screening and identification of blood group alloantibodies before transfusion of red blood cells.


Assuntos
Humanos , Antígenos de Grupos Sanguíneos , Transfusão de Sangue , Eritrócitos , Isoanticorpos , Ressonância de Plasmônio de Superfície
3.
Journal of Experimental Hematology ; (6): 1657-1661, 2015.
Artigo em Chinês | WPRIM | ID: wpr-272543

RESUMO

<p><b>OBJECTIVE</b>To investigate the irregular antibody production and its relationship with Rh factor genotypes and the loci of thalassemia gene mutations for the β-thalassemic children with long-term transfusion, so as provide experimental basis for clinical safe and effective transfusions for thalassemic children.</p><p><b>METHODS</b>The peripheral blood from 246 children with β-thalassemia was collected in our hospital; the extraction of genomic DNA and Rh factor (C/c, E/e) genotypes were assayed by PCR-SSP method, the irregular antibodies were screened and identified by serological method, the genotypes for thalassemia and gene mutations were analysed by PCR-RD method.</p><p><b>RESULTS</b>The genotypes of Rh factors classified by PCR- SSP in the 246 cases of β-thalassemia children were as follws: Ce/Ce (143/246, 58.1%), CE/ce (59/246, 24%), cE/cE (14/24, 5.7%), Ce/ce (12/246, 4.9%); The positive rate of irregular antibody was 7.7% (19/246), including anti-E (7/19), anti-c (5/19), anti-C (2/19), anti-E and anti-c (2/19), anti-e (1/19), anti-D (2/19); Of the 19 cases with positive irregular antibody, the genotypings of Rh factor were: Ce/Ce (11/19), CE/ce (2/19), cE/cE (2/19), Ce/ce (2/19), cE/ce (2/19); the gene mutations location of thalassemia for 19 cases with positive irregular antibody: CD41-42M (13/19), CD71-72M (2/19), IVS-II-654M (3/19), -28M (1/19).</p><p><b>CONCLUSION</b>The irregular antibody production for β-thalassemic children with long-term transfusion may have some relevance with Rh factor genotypes and thalassemia genetic mutations. This study possesses a certain significance for effective prevention of RBC alloimmune response of β-thalassemia children and improvement of efficacy and safety of clinical transfasion blood.</p>


Assuntos
Criança , Humanos , Antígenos de Grupos Sanguíneos , Transfusão de Sangue , Genótipo , Histocompatibilidade , Mutação , Reação em Cadeia da Polimerase , Sistema do Grupo Sanguíneo Rh-Hr , Imunoglobulina rho(D) , Talassemia beta
4.
Journal of Experimental Hematology ; (6): 1517-1521, 2013.
Artigo em Chinês | WPRIM | ID: wpr-264984

RESUMO

This study was aimed to detect the level of the peripheral blood Breg and CD4(+) T cell subgroups in patients with chronic idiopathic thrombocytopenic purpura (CITP) before and after therapy, and to analyse the charge of related cytokines and their correlation, to explore their roles in the pathogenesis of CITP. A total of 35 CITP cases were taken as the research group and 35 healthy persons were served as the control group. The peripheral blood mononuclear cells (PBMNC) were separated, the percentages of Th1, Th17, Th22 and Breg cells were detected by flow cytometry before and after treatment of glucocorticoid, and the IFN-γ, IL-17, IL-22 and IL-10 levels from PBMNC culture supernatant also were determined by ELISA. The results showed that there was significant difference as compared with the healthy controls, the proportion of peripheral blood Th1, Th17, Th22 cell subgroups all increased in CITP patients before treatment with glucocorticoid, the regulatory B cells (Breg) ratio was reduced, the differences had statistical significance (P < 0.05), but the differences were no statistically significant after treatment with glucocorticoid (P > 0.05). The levels of IFN-γ, IL-17, IL-22 from culture supernatant all increased in CITP patients before treatment, the level of IL-10 was lower than that of the healthy control, the difference was statistically significant (P < 0.05), but the there were no statistically significant differences after treatment (P > 0.05). There were positive correlation between the Breg cells and IL-10 expression in CITP patients (P < 0.05), the Breg cells and Th1, Th17, Th22 cells showed a negative correlation, IL-10 and IFN-γ, IL-17, IL-22 levels also showed a negative correlation. It is concluded that the down-regulation of regulatory B cells proportion and the IL-10 level may participate in the mechanism of CD4(+) T cell immunity disorder in CITP, which can provide new targets and ideas for the clinical immune regulation therapy.


Assuntos
Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Linfócitos B Reguladores , Biologia Celular , Alergia e Imunologia , Linfócitos T CD4-Positivos , Biologia Celular , Alergia e Imunologia , Estudos de Casos e Controles , Células Cultivadas , Interleucina-10 , Alergia e Imunologia , Púrpura Trombocitopênica Idiopática , Sangue , Alergia e Imunologia , Células Th1 , Células Th17