Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Braz. j. otorhinolaryngol. (Impr.) ; 88(4): 533-538, July-Aug. 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1394155

RESUMO

Abstract Introduction: The bone-anchored hearing system has become the most viable treatment option for subjects with conductive or mixed hearing loss, who are unable to benefit from conventional hearing aids or middle ear surgery. Objective: To compare the surgical and audiological outcomes between the minimally-invasive Ponto surgery and a linear incision with soft tissue preservation techniques in bone-anchored hearing system recipients. Methods: A retrospective study was carried out from January 2017 to June 2018. Forty-two adult patients eligible for unilateral bone-anchored hearing system surgery with the Ponto system were included in the study. The implant and abutment lengths used varied from 3 to 4 mm and from 6 to 14 mm, according to the bone and skin thickness of the participants, respectively. Results: Twenty-two surgeries were performed using the minimally invasive Ponto surgery technique (52.4%) and 20 (47.6%) using the linear incision. The mean age of the subjects implanted with minimally invasive Ponto surgery and linear incision techniques were 42.0 and 33.3 years old, respectively. Ten male (45,5%) and 14 (70%) female patients were implanted using minimally invasive Ponto surgery and the linear incision techniques, respectively. There were no differences between pure tone audiometric thresholds and monosyllabic word recognition scores of the subjects, when comparing both surgical techniques. The minimally invasive Ponto surgery technique significantly reduced the surgical time compared to the linear incision technique. There were no differences between both surgical techniques for skin-related complications; (Holgers 3 and 4) which occurred in 18.8% for MIPS and in 25% for linear incision. Subjects included in the minimally invasive Ponto surgery technique group showed a superior cosmetic outcome, with no surgical scar or additional sutures. Conclusion: The surgical and audiological outcomes were satisfactory and were not correlated to the surgical technique selected in all subjects. When compared to the linear incision, the minimally invasive Ponto surgery technique showed reduced surgical time and superior esthetic outcomes in the postoperative follow-up.


Resumo Introdução: As próteses auditivas ancoradas ao osso têm se tornado a opção de tratamento mais viável para indivíduos com perda auditiva condutiva ou mista, incapazes de se beneficiar de aparelhos auditivos convencionais ou cirurgia da orelha média. Objetivo: Comparar os resultados cirúrgicos e audiológicos entre as técnicas minimally invasive Ponto surgery e incisão linear com preservação de tecidos moles em usuários de próteses auditivas ancoradas ao osso. Método: Foi feito um estudo retrospectivo de janeiro de 2017 a junho de 2018. Foram incluídos no estudo 42 pacientes adultos candidatos para cirurgia de prótese auditiva ancorada ao osso unilateral com o sistema Ponto. Os comprimentos de implante e pilar usados variaram de 3-4 milímetros e de 6-14 milímetros, de acordo com a espessura óssea e subcutânea dos participantes, respectivamente. Resultados: Foram feitas 22 cirurgias com uso da técnica minimally invasive Ponto surgery (52,4%) e 20 (47,6%) com incisão linear. A idade média dos indivíduos implantados com técnicas minimally invasive Ponto surgery e incisão linear foi de 42 e 33,3 anos, respectivamente. Dez homens (45,5%) e 14 (70%) mulheres foram implantadas com técnicas minimally invasive Ponto surgery e incisão linear, respectivamente. Não houve diferenças entre os limiares audiométricos em campo livre e as pontuações de reconhecimento de palavras monossilábicas dos sujeitos, quando comparadas as duas técnicas cirúrgicas. A técnica minimally invasive Ponto surgery reduziu significantemente o tempo cirúrgico em comparação com a técnica de incisão linear. Não houve diferenças entre as duas tecnicas cirúrgicas para complicações cutâneas maiores (Holgers 3 e 4), que ocorreram em 18,18% para MIPS e em 25% para incisão linear. Os indivíduos incluídos no grupo da técnica minimally invasive Ponto surgery apresentaram aspecto cosmético superior, sem cicatriz cirúrgica ou sutura adicional. Conclusão: Os resultados cirúrgicos e audiológicos foram satisfatórios e não se correlacionaram com a técnica cirúrgica empregada em todos os indivíduos. Quando comparada à incisão linear, a técnica minimally invasive Ponto surgery apresentou tempo cirúrgico reduzido e resultados estéticos superiores no seguimento pós-operatório.

2.
Braz. j. otorhinolaryngol. (Impr.) ; 88(supl.1): 108-117, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1420796

RESUMO

Abstract Introduction Electrically evoked auditory brainstem responses provide reliable clinical information to assist professionals in the auditory rehabilitation of cochlear implant users. Objective This study aimed to investigate intraoperative evoked auditory brainstem response recordings in Evo®-cochlear implant electrode array recipients and its correlation with their behavioral levels and auditory performance. Methods This is a retrospectivey study. Intraoperative evoked auditory brainstem responses were recorded in adult Evo®-cochlear implant electrode array recipients. Wave V latencies, amplitudes and interpeak III-V intervals were recorded in three different electrode locations and compared to the sentence recognition scores obtained from subjects after six months of device use. Evoked auditory brainstem responses thresholds were also recorded and compared to the behaviorally determined levels of the subjects in the sound processor activation. Results Evoked auditory brainstem responses thresholds were significantly correlated with both, behavioral T- and C-levels and they were recorded at audible electrical stimulation levels in all subjects. There was a significant correlation between interpeak III-V interval recorded in the apical electrode and sentence recognition scores of the subjects. Conclusions Intraoperative evoked auditory brainstem responses can be used to establish audible levels for fitting the sound processor in Evo®-cochlear implant recipients and it could help professionals to plan further actions aiming to improve their auditory performance.


Resumo Introdução Os potenciais auditivos de tronco encefálico evocados eletricamente fornecem informações clínicas confiáveis que auxiliam no processo de reabilitação auditiva de usuários de implante coclear. Objetivo Investigar o registro intraoperatório dos potenciais auditivos de tronco encefálico evocados eletricamente em usuários do feixe de eletrodos Evo® e sua correlação com os níveis comportamentais e desempenho auditivo dos indivíduos. Método Estudo retrospectivo. Os potenciais auditivos de tronco encefálico intraoperatórios foram registrados em usuários adultos de implante coclear com feixe de eletrodos Evo®. As latências e amplitudes da onda V e os intervalos interpico III-V foram registrados em três diferentes eletrodos e comparados às pontuações de reconhecimento de sentenças após 6 meses de uso do implante coclear. Os limiares dos eABRs foram comparados aos níveis comportamentais dos indivíduos na ativação do processador de som. Resultados Os limiares do eABR foram significativamente correlacionados aos níveis comportamentais T e C e registrados em níveis de estimulação elétrica audíveis em todos os indivíduos. Houve uma correlação significativa entre o intervalo interpico III-V no eletrodo apical e a pontuação de reconhecimento de sentenças dos indivíduos. Conclusões O eABR intraoperatório pode ser usado para estabelecer níveis audíveis de estimulação elétrica na ativação do processador sonoro em usuários de implante coclear‐Evo® e pode auxiliar os profissionais no planejamento de ações visando melhorar o desempenho auditivo nesses pacientes.

3.
Int. arch. otorhinolaryngol. (Impr.) ; 20(4): 353-358, Oct.-Dec. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-828917

RESUMO

Abstract Introduction The preservation of residual hearing is currently an important challenge for cochlear implant surgeries. Indeed, if patients exhibit functional hearing after cochlear implantation, they can benefit from the combination of acoustical stimulation, usually in the low-frequencies and electrical stimulation in the high-frequencies. This combined mode of stimulation has proven to be beneficial both in terms of speech perception and of sound quality. Finding the right procedures for conducting softsurgeries and designing electrode arrays dedicated to hearing preservation is an open issue. Objective The objective of this study is to evaluate the combination of a soft-surgery procedure implicating round-window insertion and the use of dexamethasone and hyaluronic acid during surgery, with the use of a specifically designed straight soft electrode array, on hearing preservation in patients with functional hearing in the low frequencies. Methods This pre-clinical trial was conducted on seven patients with residual hearing in the low frequencies. The surgical method used employed a round window insertion and the use of topical dexamethasone. Results The soft-surgery protocol could be successfully followed in five patients. In this group, the average hearing threshold shift compared with pre-operative values was of 18.7 þ/ 16.1 dB HL up to 500 Hz and 15.7 þ/ 15.1 up to 1 kHz, demonstrating satisfying levels of hearing preservation. Conclusion We were able to demonstrate the possibility of preserving residual hearing in most of the patients using the EVO electrode. Significant residual hearing preservation levels were was obtained when a soft surgical approach involving round window insertion, dexamethasone and hyaluronic use during the surgery.

4.
Braz. j. otorhinolaryngol. (Impr.) ; 79(3): 298-305, maio-jun. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-675683

RESUMO

O implante coclear é um grande avanço no tratamento da surdez. Há grandes evidências que a audição bilateral traz diversas vantagens ao ser humano e muito mais quando se trata de audição binaural. OBJETIVO: Este artigo tem por objetivo descrever o primeiro caso operado no Brasil, sendo o terceiro país das Américas (México e Colômbia) a realizar, com implante binaural Neurelec Digisonic SP® demonstrando a técnica cirúrgica. MÉTODO: Descrição da técnica cirúrgica. RESULTADOS: Ver técnica cirúrgica. Procedimento ocorreu sem intercorrências. DISCUSSÃO: O efeito "squelch", a somação binaural, a localização da fonte sonora e o efeito sombra da cabeça são umas das principais razões que justificam a superioridade da reabilitação binaural. O custo do tratamento deve ser levado em conta em políticas de saúde pública. CONCLUSÃO: Custo do implante coclear é um dos grandes limitadores da bilateralidade na reabilitação desse grupo de pacientes, porém, com essa tecnologia, é possível solucionar esse problema, expondo o paciente a poucos riscos, com o uso de uma técnica cirúrgica pouco invasiva.


Cochlear implants represent a significant breakthrough in the treatment of hearing loss. Evidence indicates bilateral hearing brings significant benefits to patients, particularly when binaural hearing is offered. OBJECTIVE: To describe the first case of implantation of a Digisonic SP® Binaural Neurelec device in Brazil (the third implant placed in the Americas, after Mexico and Colombia) and the chosen surgical approach. METHOD: Description of a surgical approach. RESULTS: The procedure was successfully completed. DISCUSSION: The squelch effect, binaural summation, location of the sound source, and the shadow effect of the head are listed among the reasons to explain the superiority of binaural rehabilitation. Cost of treatment must be considered in the development of public health policies. CONCLUSION: The cost of cochlear implants has been one of the main impediments to bilateral rehabilitation. The Digisonic SP® Binaural Neurelec device addresses this issue and exposes patients to less risk through a minimally invasive implantation procedure.


Assuntos
Adulto , Feminino , Humanos , Masculino , Implantes Cocleares , Implante Coclear/métodos , Perda Auditiva Bilateral/cirurgia , Perda Auditiva Neurossensorial/cirurgia , Implante Coclear/instrumentação , Localização de Som , Percepção da Fala , Resultado do Tratamento
5.
Audiol., Commun. res ; 18(1): 17-23, jan.-mar. 2013. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-676860

RESUMO

OBJETIVO: Estudar comparativamente a habilidade de reconhecimento de fala no silêncio e na presença de ruído competitivo em crianças usuárias de implante coclear utilizando dois diferentes processadores de fala. MÉTODOS: Foram avaliadas 26 crianças usuárias do implante coclear Nucleus 24M/24K, da Cochlear Corporation®, divididas em dois grupos de acordo com o processador de fala utilizado. O Grupo 1 foi composto por 16 crianças que faziam uso do processador de fala Sprint e o Grupo 2 foi composto por 10 crianças que faziam uso do processador de fala Freedom. Foi aplicado o Hearing in Noise Test - versão em Português/Brasil, em campo livre, na condição de silêncio e na presença de ruído competitivo. RESULTADOS: O desempenho do Grupo 2 (Freedom) foi superior ao desempenho do Grupo 1 (Sprint) em todas as condições de avaliação, sendo evidenciada diferença entre eles na condição de silêncio. CONCLUSÃO: O processador de fala apresentou influência significativa na percepção de fala de crianças usuárias dos implantes cocleares Nucleus 24K e 24M. As características de pré-processamento do som presentes no processador de fala Freedom podem ter contribuído para o melhor desempenho do Grupo 2 nos testes de percepção de fala realizados. Novos estudos são necessários para complementação destes achados.


PURPOSE: To study comparatively the speech recognition skills in quiet and noise background situation in children with cochlear implants using two different speech processors. METHODS: It was evaluated 26 children with cochlear implant device Nucleus 24M or 24K, Cochlear Corporation, divided in two groups according to the speech processor used. The Group 1 consisted of 16 children who used the Sprint processor and the Group 2 consisted of 10 children who used the Freedom processor. The Hearing in Noise Test - Portuguese version of Brazil was applied in the sound field in silence and in the presence of noise background situation. RESULTS: The speech recognition performance of Group 2 (Freedom) was higher than Group 1 (Sprint) in all evaluation situations, with significant difference between groups only on quiet situation. CONCLUSION: The speech processor showed significant influence on speech perception in children users of Nucleus 24K and 24M cochlear implants. The components of the signal processing available on the Nucleus Freedom processor may have contributed to the better speech recognition performance of Group 2. Further research is needed to complement these findings.


Assuntos
Humanos , Criança , Implante Coclear , Auxiliares de Comunicação para Pessoas com Deficiência , Acústica da Fala , Interface para o Reconhecimento da Fala , Perda Auditiva , Perda Auditiva Neurossensorial , Testes Auditivos , Audiômetros
6.
Braz. j. otorhinolaryngol. (Impr.) ; 78(6): 56-62, nov.-dez. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-660412

RESUMO

O implante coclear para pacientes com disacusia grave/profunda revolucionou o modo com que estes interagem com o meio ambiente. A Neurelec desenvolveu um sistema que permite fixação com uso de dois simples parafusos de titânio, sem necessidade de broqueamento do osso do crânio do paciente. Este artigo teve o objetivo de descrever uma casuística de pacientes submetidos a implante coclear com o Digisonic® SP, para mostrar os resultados cirúrgicos e detalhes do procedimento. MÉTODO: Estudo retrospectivo que avaliou os pacientes, no período de 18 meses, submetidos a implante coclear com o Digisonic® SP. Todos os pacientes eram pós-linguais. Coleta dos dados realizada por meio da análise dos prontuários dos pacientes, além de questionário padronizado aplicado nos cirurgiões que realizaram o procedimento. RESULTADOS: Os seis casos implantados com o Digisonic® SP foram realizados por cirurgiões experientes e o tempo cirúrgico variou de 95 a 203 minutos (média de 135 minutos), que é menor do que o descrito com outras formas de fixação. Não houve nenhum tipo de complicação e o ganho auditivo foi satisfatório. CONCLUSÃO: O implante Digisonic® SP desenvolvido pela Neurelec apresentou bons resultados audiológicos em adultos, tempo de cirurgia menor e não ocorreram complicações cirúrgicas ou pós-operatórias.


Cochlear implants have revolutionized the way patients affected by severe hearing loss experience the world. Neurelec developed a fixation system with two titanium screws that requires no skull bone drilling. OBJECTIVE: To describe the outcomes and procedure-related details of a series of patients implanted with the Digisonic® SP cochlear implant. METHOD: This retrospective study analyzed patients submitted to cochlear implant placement within a period of 18 months. All patients had postlingual hearing impairment. Data was collected from patient charts and standard questionnaires answered by the surgeons in charge of carrying out the procedures. RESULTS: The six patients offered the Digisonic® SP cochlear implants were operated by experienced surgeons. The procedures took 95 to 203 minutes (mean = 135') to be completed, which is less time than what has been described for other fixation approaches. No complications were recorded and hearing improvement was satisfactory. CONCLUSION: The Digisonic® SP cochlear implant developed by Neurelec offered good audiological results for adult patients, shorter surgery time, and no surgical or postoperative complications.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Implantes Cocleares , Implante Coclear/instrumentação , Perda Auditiva/cirurgia , Parafusos Ósseos , Estudos Retrospectivos , Titânio , Resultado do Tratamento
7.
Rev. Soc. Bras. Fonoaudiol ; 16(2): 152-159, abr.-jun. 2011. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-604750

RESUMO

OBJETIVO: Adaptar culturalmente o questionário Satisfaction with Amplification in Daily Life (SADL), versão em Português Brasileiro, para administrar em usuários de aparelhos de amplificação sonora individuais (AASIs) dispensados pelo Sistema Único de Saúde (SUS). MÉTODOS: Participaram da pesquisa 19 sujeitos usuários de AASIs dispensados pelo Sistema Único de Saúde, por no mínimo três semanas, com idade igual ou superior a 60 anos, que apresentavam perda auditiva pós-lingual, sendo 63 por cento do gênero masculino e 37 por cento do gênero feminino, com média de idade de 73 anos e média de tempo de uso das próteses auditivas de cinco meses. Os sujeitos responderam ao questionário SADL e a uma Escala de Satisfação de item único, além de alguns itens adicionais. Foi realizada a análise da consistência interna do SADL, a análise descritiva dos resultados, para caracterizar as respostas dos sujeitos, a comparação dos resultados com os dados normativos propostos pelos autores e uma investigação do relacionamento entre o SADL e a escala de satisfação de item único. RESULTADOS: Os resultados obtidos para a pontuação global evidenciaram que os sujeitos, em média, encontravam-se satisfeitos com seus AASIs. O mesmo ocorreu para todas as subescalas do SADL, sendo que a subescala Imagem Pessoal apresentou o maior número de pessoas muito satisfeitas. Os resultados obtidos foram equivalentes aos encontrados pelos autores e o SADL mostrou ser um questionário com boa consistência interna (0,71). Houve íntima relação entre a escala de satisfação de item único e a pontuação global do SADL. Para as duas medidas de satisfação, a maioria dos sujeitos demonstrou estar satisfeito com seus AASIs e ambas as escalas apresentaram correlação alta e significativa (0,935). CONCLUSÃO: Em média, os sujeitos estavam satisfeitos com seus AASIs dispensados pelo SUS...


PURPOSE: To culturally adapt the Brazilian Portuguese version of the Satisfaction with Amplification in Daily Life (SADL) questionnaire to be administered in users of hearing aids dispensed by Brazil's Unified Health System (SUS). METHODS: Participants were 19 subjects, users of hearing aids dispensed by SUS for at least three weeks, with ages 60 or older, who had post-lingual hearing loss. Sixty three percent of them were male and 37 percent were female, with mean age of 73 years and mean duration of hearing aids use of five months. Subjects answered the SADL questionnaire and a single-item Satisfaction Scale, besides a few additional items. The internal consistency analysis of the SADL was carried out, as well as the descriptive analysis of the results, in order to compare them to the normative data reported by the questionnaire authors. The relationship between SADL's global scores and the Satisfaction Scale were also investigated. RESULTS: The results for the overall scores evidenced that subjects, in average, were satisfied with their hearing aids. The same was true for all subscales of the SADL, and the Personal Image subscale had the largest number of people very satisfied. The results were equivalent to those found by the questionnaire authors, and the SADL showed a good internal consistency (0.71). The single-item Satisfaction Scale was closely related to the global score of the SADL. For both satisfaction measures, most subjects demonstrated to be satisfied with their hearing aids, and there was a high significant correlation between both scales (0.935). CONCLUSION: In average, subjects were satisfied with their hearing aids dispensed by SUS...


Assuntos
Masculino , Auxiliares de Audição , Perda Auditiva , Saúde Pública , Comportamento do Consumidor , Sistema Único de Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA