Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Soonchunhyang Medical Science ; : 106-109, 2021.
Artigo em Inglês | WPRIM | ID: wpr-918815

RESUMO

A key challenge of anesthesia is to provide patients with safe and optimized anesthetic management to improve prognosis and minimize mortality and morbidity. To this end, the anesthesiologist should comprehensively understand the patient’s physical status through pre-anesthetic assessment and carefully monitor the patient during surgery. Several types of novel patient-monitoring devices may be useful to achieve this purpose. We report a case of anesthetic management in a patient with left internal carotid artery occlusion and penetrating aortic ulcer.

2.
Annals of Laboratory Medicine ; : 33-39, 2020.
Artigo em Inglês | WPRIM | ID: wpr-762457

RESUMO

BACKGROUND: The interferon-gamma (IFN-γ) releasing assay (IGRA) is widely used for latent tuberculosis infection (LTBI) diagnosis. We evaluated the analytical performance of a new automated chemiluminescent immunoanalyzer-based IGRA (CLIA-IGRA), AdvanSure I3 (LG Life Sciences, Seoul, Korea) and compared it with that of the QuantiFERON-TB Gold In-Tube (QFT-GIT) assay. METHODS: Repeatability and reproducibility were evaluated at four levels. Detection capability, including limit of blank (LoB), limit of detection (LoD), and limit of quantification (LoQ), was evaluated using IFN-γ standard material (National Institute for Biological Standards and Control code: 87/586). Agreement between the results of two assays was evaluated using 341 blood samples from healthcare workers and patients at a tertiary care hospital. To determine the cut-off value of CLIA-IGRA for diagnosing LTBI, the ROC curve was analyzed. RESULTS: Repeatability and reproducibility were 4.86–7.00% and 6.36–7.88% CV, respectively. LoB, LoD, and LoQ were 0.022, 0.077, and 0.249 IU/mL, respectively. IFN-γ values between CLIA-IGRA and QFT-GIT showed a strong correlation within the analytical measurable range of both assays, especially when the value was low. Qualitative comparison of the two assays yielded a 99.1% overall agreement (kappa coefficient=0.98). A cut-off value of 0.35 IU/mL was appropriate for diagnosing LTBI. CONCLUSIONS: CLIA-IGRA is a reliable assay for LTBI diagnosis, with performance similar to that of QFT-GIT.


Assuntos
Humanos , Disciplinas das Ciências Biológicas , Atenção à Saúde , Diagnóstico , Interferon gama , Tuberculose Latente , Limite de Detecção , Curva ROC , Seul , Atenção Terciária à Saúde
3.
Soonchunhyang Medical Science ; : 45-47, 2020.
Artigo | WPRIM | ID: wpr-837181

RESUMO

Hypopharyngeal mass is an uncommon condition in the aerodigestive tract. There were only a few cases have been published in the medical literature. We experienced a case of incidentally detected hypopharyngeal mass during endotracheal intubation. Hypopharyngeal mass was located at the right posterior pharyngeal wall. The hypopharyngeal mass was small and not obstruct the glottis, and endotracheal intubation was performed successfully. We have also briefly discussed symptoms, diagnosis, and related problems during general anesthesia of hypopharyngeal mass.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA