Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Indian Pediatr ; 2022 Mar; 59(3): 230-233
Artigo | IMSEAR | ID: sea-225310

RESUMO

Objectives: To present the result of newborn sickle cell disease (SCD) screening and clinical profile of SCD newborns in a tribal area of Gujarat. Methods: We screened all newborns of sickle cell trait (SCT) and SCD mothers for SCD using high-performance liquid chromatography (HPLC) within two days of birth at a secondary care hospital in a tribal area in Gujarat from 2014 to 2019. Newborns with SCD were registered under an information technology based platform for hospital-based comprehensive care. Neonates were followed prospectively every 3 months. If they missed the clinic visit, a medical counsellor visited them at home to collect the required information. Results: Out of 2492 newborns screened, 87 (3.5%) were diagnosed with SCD. Among the 67 newborns screened for alpha-thalassemia deletion, 64 (95.4%) of babies had alpha-thalassemia deletion. We recorded total 554 clinic visits over the period of 221.5 person-years. The rates of acute febrile illness, painful crisis, hospitalization and severe anemia were 42.9, 14.9, 14.9 and 4.5 per 100 person-year, respectively. Two deaths were recorded, and 5 babies (5.7%) had severe SCD. Conclusion: We found a high prevalence of alpha thalassemia deletion among newborn SCD cohort in tribal area of Gujarat, and 70% babies had atleast one clinical complication on follow-up.

2.
Artigo em Inglês | IMSEAR | ID: sea-174072

RESUMO

The study was undertaken to determine diagnostic accuracy of Haemoglobin Colour Scale (HCS) in hands of village-based community health workers (CHWs) in real-life community setting in India. Participants (501 women) were randomly selected from 8 villages belonging to a project area of SEWA-Rural, a voluntary organization located in India. After receiving a brief training, CHWs and a research assistant obtained haemoglobin readings using HCS and HemoCueTM (reference) respectively. Sensitivity, specificity, positive and negative predictive-values, and likelihood ratios were calculated. Bland-Altman plot was constructed. Mean haemoglobin value, using HCS and HemoCueTM were 11.02 g/dL (CI 10.9-11.2) and 11.07 g/dL (CI 10.9-11.2) respectively. Mean difference between haemoglobin readings was 0.95 g/dL. Sensitivity of HCS was 0.74 (CI 0.65-0.81) and 0.84 (CI 0.8-0.87) whereas specificity was 0.84 (CI:0.51-0.98) and 0.99 (CI:0.97- 0.99) using haemoglobin cutoff limits of 10 g/dL and 7 g/dL respectively. CHWs can accurately diagnose severe and moderately-severe anaemia by using HCS in real-life field condition after a brief training.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA