Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Korean Dental Science ; : 1-8, 2022.
Artigo em Inglês | WPRIM | ID: wpr-938000

RESUMO

Purpose@#Intraoral scanners, desktop scanners, and cone-beam computed tomography (CBCT) are being used in a complementary way for diagnosis and treatment planning. Limited patient-based results are available about dimensional reproducibility among different three-dimensional imaging systems. This study aimed to evaluate dimensional reproducibility among patient-derived digital models created from an intraoral scanner, desktop scanner, and two CBCT systems. @*Materials and Methods@#Twenty-nine arches from sixteen patients who were candidates for implant treatments were enrolled. Different types of CBCT systems (KCT and VCT) were used before and after the surgery. Polyvinylsiloxane impressions were taken on the enrolled arches after the healing period. Gypsum casts were fabricated and scanned with an intraoral scanner (CIOS) and desktop scanner (MDS). Four test groups of digital models, each from CIOS, MDS, KCT, and VCT, respectively, were compared to the reference gypsum cast group. For comparison of linear measurements, intercanine and intermolar widths and left and right canine to molar lengths were measured on individual gypsum cast and digital models. All measurements were triplicated, and the averages were used for statistics.Bland–Altman plots were drawn to assess the degree of agreement between each test group with the reference gypsum cast group. A linear mixed model was used to analyze the fixed effect of the test groups compared to the reference group (α=0.05).Result: The Bland–Altman plots showed that the bias of each test group was –0.07 mm for CIOS, –0.07 mm for MDS, –0.21 mm for VCT, and –0.25 mm for KCT. The linear mixed model did not show significant differences between the test and reference groups (P>0.05). @*Conclusion@#The linear distances measured on the digital models created from CIOS, MDS, and two CBCT systems showed slightly larger than the references but clinically acceptable reproducibility for diagnosis and treatment planning.reproducibility for diagnosis and treatment planning.plots showed that the bias of each test group was –0.07 mm for CIOS, –0.07 mm for MDS,

2.
The Journal of Korean Academy of Prosthodontics ; : 35-41, 2020.
Artigo em Coreano | WPRIM | ID: wpr-786594

RESUMO

Patients with collapsed occlusal support and unilateral chewing show parafunctional mandibular movements, which can be complicated in older patients. Gothic arch tracing and split cast technique are used to confirm the deviation between centric relation and anterior habitual bite in patient who has oral dyskinesia and collapsed occlusion. Temporary denture as occlusal stabilization appliance was provided for stable occlusion and reproducible mandibular movement. Definitive denture was fabricated by lingualized occlusion concept.


Assuntos
Humanos , Relação Central , Dentaduras , Mandíbula , Mastigação , Reabilitação Bucal , Boca , Transtornos dos Movimentos , Próteses e Implantes
3.
The Journal of Advanced Prosthodontics ; : 88-94, 2019.
Artigo em Inglês | WPRIM | ID: wpr-742082

RESUMO

PURPOSE: This study was conducted to investigate patterns of adjacent tooth displacement in the posterior implant with interproximal contact loss (ICL) by 3-D digital superimposition method. MATERIALS AND METHODS: Posterior partially edentulous patients, restored with implant fixed partial prostheses before 2011 and suffered from food impaction of ICL between 2009 and 2011, were included. Two dental casts, at the time of delivery and at the time of food impaction in a same patient, was converted into 3-D digital models through scanning and superimposition was performed to assess chronologic changes of the dentition. Directions of tooth displacement were evaluated and the amount of ICL was calculated. Correlations between the amount of ICL and elapsed time, or between the amount of ICL and age after function, were assessed at a significance level of P.05). CONCLUSION: Natural teeth showed various directional movements to result in occlusal change in the arch. The 3-D superimposition of chronologic digital models was a helpful method to analyze the changes of dentition and individual tooth displacement adjacent to implant restoration.


Assuntos
Humanos , Masculino , Implantes Dentários , Dentição , Maxila , Métodos , Próteses e Implantes , Estudos Retrospectivos , Dente
4.
The Journal of Korean Academy of Prosthodontics ; : 410-418, 2017.
Artigo em Coreano | WPRIM | ID: wpr-91592

RESUMO

Amelogenesis imperfecta characterized as abnormally formed enamel is caused by a defect of unique group of genes. Patients affected by this disease might have difficulties in social and psychological aspects due to non-esthetic teeth as well as functional problems caused by enamel detachment and tooth wear from their early ages. Adult patients with amelogenesis imperfecta can be treated with full-mouth restorations, which make functional and esthetic rehabilitations of severely worn tooth. However, the anterior open bite and lack of occlusal clearance for posterior teeth restorations due to compensatory extrusion are the intervening factors in the prosthetic treatment. Therefore, the determination of anterior tooth lengths, vertical dimension, and anterior guidance should be set carefully. Recently, computer-aided design and computer-aided manufacturing (CAD/CAM) techniques help systematic approaches and enable dentists to reduce time-consuming procedures in the diagnosis and treatment of full-mouth rehabilitation. This case report demonstrates the successful full mouth rehabilitation using a CAD/CAM system in a young adult patient with amelogenesis imperfecta and anterior open bite.


Assuntos
Adulto , Humanos , Adulto Jovem , Amelogênese Imperfeita , Amelogênese , Desenho Assistido por Computador , Esmalte Dentário , Odontólogos , Diagnóstico , Reabilitação Bucal , Mordida Aberta , Reabilitação , Dente , Desgaste dos Dentes , Dimensão Vertical
5.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 337-344, 2016.
Artigo em Inglês | WPRIM | ID: wpr-27966

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the anti-cancer activity of cisplatin by studying its effects on cell viability and identifying the mechanisms underlying the induction of cell cycle arrest and apoptosis on oral squamous cell carcinoma (OSCC) cell lines with varying p53 mutation status. MATERIALS AND METHODS: Three OSCC cell lines, YD-8 (p53 point mutation), YD-9 (p53 wild type), and YD-38 (p53 deletion) were used. To determine the cytotoxic effect of cisplatin, MTS assay was performed. The cell cycle alteration and apoptosis were analyzed using flow cytometry. Western blot analysis was used to detect the expression of cell cycle alteration- or apoptosis-related proteins as well as p53. RESULTS: Cisplatin showed a time- and dose-dependent anti-proliferative effect in all cell lines. Cisplatin induced G2/M cell accumulation in the three cell lines after treatment with 0.5 and 1.0 µg/mL of cisplatin for 48 hours. The proportion of annexin V-FITC-stained cells increased following treatment with cisplatin. The apoptotic proportion was lower in the YD-38 cell line than in the YD-9 or YD-8 cell lines. Also, immunoblotting analysis indicated that p53 and p21 were detected only in YD-8 and YD-9 cell lines after cisplatin treatment. CONCLUSION: In this study, cisplatin showed anti-cancer effects via G2/M phase arrest and apoptosis, with some difference among OSCC cell lines. The mutation status of p53 might have influenced the difference observed among cell lines. Further studies on p53 mutation status are needed to understand the biological behavior and characteristics of OSCCs and to establish appropriate treatment.


Assuntos
Apoptose , Western Blotting , Carcinoma de Células Escamosas , Ciclo Celular , Pontos de Checagem do Ciclo Celular , Linhagem Celular , Sobrevivência Celular , Cisplatino , Células Epiteliais , Citometria de Fluxo , Immunoblotting
6.
The Journal of Korean Academy of Prosthodontics ; : 191-198, 2009.
Artigo em Coreano | WPRIM | ID: wpr-89054

RESUMO

STATEMENT OF PROBLEM: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. PURPOSE: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. MATERIAL AND METHODS: Heat pressed ceramic (ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire (Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens (width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine (Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope (JSM-6360, JEOL, Japan) under platinum coating. RESULTS: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics (P < .001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. CONCLUSION: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.


Assuntos
Humanos , Resinas Acrílicas , Vértebra Cervical Áxis , Cerâmica , Colódio , Resinas Compostas , Coroas , Prótese Parcial Fixa , Elétrons , Temperatura Alta , Compostos de Lítio , Boca , Platina , Poliuretanos , Reforço Psicológico , Entorses e Distensões , Dente , Ceras
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA