Imaging Science in Dentistry ; : 171-179, 2022.
Artigo em Inglês | WPRIM | ID: wpr-937648

RESUMO

Purpose@#The aim of this study was to assess the accuracy of cone-beam computed tomographic (CBCT) images obtained using different voxel sizes in measuring trabecular bone microstructure in comparison to micro-CT. @*Materials and Methods@#Twelve human skull bones containing posterior-mandibular alveolar bone regions were analyzed. CBCT images were obtained at voxel sizes of 0.075 mm (high: HI) and 0.2 mm (standard: Std), while micro-CT imaging used voxel sizes of 0.06 mm (HI) and 0.12 mm (Std). Analyses were performed using CTAn software with the standardized automatic global threshold method. Intraclass correlation coefficients were used to evaluate the consistency and agreement of paired measurements for bone volume (BV), percent bone volume (BV/TV), bone surface (BS), trabecular thickness (TbTh), trabecular separation (TbSp), trabecular number (TbN), trabecular pattern factor (TbPf), and structure model index (SMI). @*Results@#When compared to micro-CT, CBCT images had higher BV, BV/TV, and TbTh values, while micro-CT images had lower BS, TbSp, TbN, TbPf, and SMI values (P<0.05). The BV, BV/BT, TbTh, and TbSp variables were higher with Std voxels, whereas the BS, TbPf, and SMI variables were higher with HI voxels for both imaging methods. For each imaging modality and voxel size evaluated, BV, BS, and TbTh were significantly different (P<0.05). TbN, TbPf, and SMI showed statistically significant differences between imaging methods (P<0.05). The consistency and absolute agreement between micro-CT and CBCT were excellent for all variables. @*Conclusion@#This study demonstrated the potential of high-resolution CBCT imaging for quantitative bone morphometry assessment.

2.
Imaging Science in Dentistry ; : 109-115, 2017.
Artigo em Inglês | WPRIM | ID: wpr-191868

RESUMO

PURPOSE: The aim of this study was to assess the ex vivo diagnostic ability of 9 different cone-beam computed tomography (CBCT) settings in the detection of recurrent caries under amalgam restorations in primary teeth. MATERIALS AND METHODS: Fifty-two primary teeth were used. Twenty-six teeth had dentine caries and 26 teeth did not have dentine caries. Black class II cavities were prepared and restored with amalgam. In the 26 carious teeth, recurrent caries were left under restorations. The other 26 intact teeth that did not have caries served as controls. Teeth were imaged using a 100×90-mm field of view and a 0.2-mm voxel size with 9 different CBCT settings. Four observers assessed the images using a 5-point scale. Kappa values were calculated to assess observer agreement. CBCT settings were compared with the gold standard using a receiver operating characteristic analysis. The area under the curve (AUC) values for each setting were compared using the chi-square test, with a significance level of α=.05. RESULTS: Intraobserver kappa values ranged from 0.366 to 0.664 for observer 1, from 0.311 to 0.447 for observer 2, from 0.597 to 1.000 for observer 3, and from 0.869 to 1 for observer 4. Furthermore, interobserver kappa values among the observers ranged from 0.133 to 0.814 for the first reading and from 0.197 to 0.805 for the second reading. The highest AUC values were found for setting 5 (0.5916) and setting 3 (0.5886), and were not found to be statistically significant (P>.05). CONCLUSION: Variations in tube voltage and tube current did not affect the detection of recurrent caries under amalgam restorations in primary teeth.


Assuntos
Área Sob a Curva , Tomografia Computadorizada de Feixe Cônico , Cárie Dentária , Dentina , Diagnóstico , Curva ROC , Dente , Dente Decíduo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA