Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Safety and Health at Work ; : 500-506, 2022.
Artigo em Inglês | WPRIM | ID: wpr-968591

RESUMO

This study evaluated the consistency between two quantitative fit test devices with different methods of ambient aerosol counting. Three types of respirators (N95, half mask, and full facepiece) were worn by 50 participants (male, n = 25; female, n = 25), PortaCount (Pro+ 8038) and MT (05U) were connected to one probe to one mask, and fit factors (FFs) were measured simultaneously with the original and modified protocols. As a result of comparing MT FFs with PortaCount FFs as references and by applying for the pass/fail criteria (FF = 100), the consistency between the two devices for half masks and full facepieces was very high. N95 was somewhat weaker than the two type of respirators in the consistency; however, the correlation between the two devices was very strong (p < 0.0001). The results showed that an FF of 100 as measured by PortaCount was likely to be measured as 75 by the MT. Therefore, when performing the fit test for N95 using the MT and pass level of FF 100, a certain level of adjustment is necessary, whether end-user or putting a scaling factor by manufacturer.

2.
Safety and Health at Work ; : 424-431, 2021.
Artigo em Inglês | WPRIM | ID: wpr-918767

RESUMO

Background@#This study aims to introduce the formulation of the regulation for the selection of respirators for accident preparedness chemicals (APCs) according to chemical workplace situations and to determine on-site applicability. @*Methods@#Workplaces were grouped into seven work categories, and APCs were classified into six groups to select adequate respirators. A survey was conducted to enhance the understanding of work situations and adequate respirators. The total number of subjects surveyed in 2018 was 201 managers and handlers, and that in 2019 was 91 handlers and 204 managers. @*Results@#Adequate respirators were allocated to each cell using the matrix method. The study observed an overall lack of understanding of work situations, especially in the operation of open devices, which was the highest at 32.7%. Despite its implementation in 2015, 17.6% and 25.0% of the managers and APCs handlers, respectively, were unaware of the regulations for selecting respirators. Only 70.4% of the APCs handler wore respirators in compliance with regulations. @*Conclusion@#The method for selecting respirators according to work situations using the matrix method is considered reasonable. Thus, this study suggests that the development of educational contents and reinforcing education should be essential steps to increasing awareness of regulations.

3.
Korean Journal of Preventive Medicine ; : 440-448, 1998.
Artigo em Coreano | WPRIM | ID: wpr-225254

RESUMO

In many developed countries, for example, USA, respirator fit testing is required before entering specific work environment to ensure that the respirator worn satisfies a minimum of fit and that the user knows when the respirator fits properly. Unfortunately because we have not fit test regulation in Korea, a lot of workers wearing respirators may be potentially exposed to hazards. This study was conducted to evaluate the fitting performance for respirators and correlation fit factors with facial dimensions of wearers. 110 subjects (70 males, 40 females) were fit tested for three quarter masks, i.e., two domestic-made Mask Z, and Y and one foreign-made Mask T using PortaCount 8020. A facial dimension survey of the same subjects was conducted to develop a facial dimension grids for correlation fit factors with facial dimension parameters. A facial dimension grid was developed on the basis of face length and lip length for quarter masks. The results obtained were as follows: 1. Fit factors of Mask T were much higher than those of Masks Z, and Y. 2. Males were fitted more properly than females. 3. Male in box "f" of grid would be adequately fitted Mask Y and male in box "b", "e", "f", "h" of grid would be sufficiently fitted Mask T. Female in box "h" of grid may have a good fitting performance for both Mask Y, and T. But subjects in all boxes of grid would be inadequately fitted Mask Z.


Assuntos
Feminino , Humanos , Masculino , Países Desenvolvidos , Coreia (Geográfico) , Lábio , Máscaras , Ventiladores Mecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA