Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. méd. Chile ; 129(11): 1263-1270, nov. 2001. graf
Artigo em Espanhol | LILACS | ID: lil-302632

RESUMO

Background: The Friedewald formula is used to estimate cholesterol of low density lipoprotein (LDL) from total cholesterol (CT), cholesterol of high density lipoprotein (HDL) and triglycerides (TG), but there are doubts about its precision. Aim: To compare Friedewald formula and regression analysis for the calculation of LDL cholesterol. Material and methods: One hundred and fifty plasma samples from asymptomatic adults (aged 47.7 ñ 13 years, 50.6 percent male) were analyzed. CT, HDL, LDL and TG were determined by enzymatic methods. Friedewald formula (LDLc=CT-HDL-(TG/5)) and multiple regression analysis were applied to estimate LDL concentration. Results: Mean total cholesterol was 175.3 ñ 39.7 mg/dl, HDL cholesterol was 35.57 ñ 0.8 mg/dl and TG was 128.4 ñ 65.4 mg/dl. Mean values for LDL cholesterol were significantly higher than those estimated by the Friedewald formula (136.4 ñ 37.9 mg/dl and 114.1 ñ 37.4 mg/dl respectively, p<0.001) with a mean underestimation of 16.4 ñ 11.7 percent. LDL cholesterol values were directly proportional to TG concentration. Multiple regression analysis (LDLr=-14.376 + (age x 0.198) + (CT x 0.949) + (HDL x -0.474) + (TG x -0.064) showed no statistical differences with those obtained by the enzymatic method. Conclusions: These results confirm the underestimation of LDL concentration by the Friedewald formula despite normal range of TG concentration. A multiple regression analysis should be used to estimate LDL concentration with precision


Assuntos
Humanos , Masculino , Feminino , Hipercolesterolemia , LDL-Colesterol , Valores de Referência , HDL-Colesterol , Análise de Regressão , Protocolos Clínicos
2.
Salus ; 3(1): 3-6, abr. 1999. tab
Artigo em Espanhol | LILACS | ID: lil-502434

RESUMO

En el presente reporte se describe un programa desarrollado en lenguaje BASIC compilado que permite usar una computadora como contador diferencial de células, objetos o eventos con mayor versatilidad y precisión que los contadores disponibles en el mercado. El programa permite las siguientes modalidades: a) Conteo simple; b) Conteo simple con tiempo definido (1 a 999.999 segundos); c) Conteo diferenciado (hasta 18 canales); d) Conteo diferenciado (hasta 18 canales) con total definido (1 a 999.999 segundos) y e) Conteo diferenciado (hasta 18 canales) con tiempo definido (1 a 999.999 segundos). El usuario configura los colores de la pantalla y las características de las modalidades de conteo según sus necesidades. El programa está formado por una rutina de configuración (SETUP.EXE) de 47 kilobytes y otra de conteo (CONTADOR.EXE) de 58 kilobytes, que se ejecutan sin requerimientos especiales del equipo de computación. Los resultados de los conteos se pueden imprimir facilitando el proceso de conteos repetidos. El programa de conteo desarrollado cubre las necesidades existentes, a este respecto, en la mayoría de los laboratorios clínicos, de investigación o de áreas industriales


Assuntos
Diagnóstico Diferencial , Laboratórios/estatística & dados numéricos , Linguagens de Programação , Software , Biologia Computacional , Venezuela
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA