1.
Korean Journal of Ophthalmology ; : 398-403, 2020.
Artigo | WPRIM | ID: wpr-835061

RESUMO

Purpose@#To evaluate the concentration of serum cystatin C (CysC) in patients with Graves’ ophthalmopathy (GO) and the us-ability of the serum CysC concentrations in the follow-up of the disease. @*Methods@#Thirty patients with GO and 30 healthy age-matched volunteers were included in this cross-sectional study. GO was diagnosed based on the European Group on Graves’ Orbitopathy consensus. Serum thyroid-stimulating hormone, free triiodothyronine, free thyroxine, and CysC concentrations were measured in the participants. The serum CysC concentrations were compared between patients with GO and controls. Patients with GO were subdivided into hyperthyroid and euthyroid patients, and their serum CysC concentrations were compared. In addition, the CysC concentrations in hyperthyroid and eu-thyroid patients with GO were compared separately with those of healthy subjects. Kruskal-Wallis test and Student’s t-test were used for statistical evaluation. @*Results@#The mean serum CysC concentrations in GO patients and controls were 1.04 ± 0.36 and 0.74 ± 0.09 mg/L, respectively.There was a statistically significant difference in the serum CysC concentrations between patients with GO and control subjects (p < 0.001). Fifteen patients had hyperthyroid status, and 15 patients had euthyroid status. The mean serum CysC concentrations in hyperthyroid and euthyroid patients with GO were 1.35 ± 0.22 and 0.72 ± 0.13 mg/L, respectively. Serum CysC concentrations were significantly higher in hyperthyroid patients than in euthyroid patients (p = 0.001). In addition, hyperthyroid patients had significantly higher serum CysC concentrations than healthy subjects. Among patients with GO, 21 and nine had mild and moder-ate-to-severe GO, respectively. Active and inactive GO were observed in eight and 22 patients, respectively. @*Conclusions@#The serum CysC concentrations in hyperthyroid patients were higher than those in healthy subjects. Moreover, hyperthyroid patients had higher serum CysC concentrations than euthyroid patients. Further studies with a larger sample size are needed to confirm these results.

2.
Korean Journal of Ophthalmology ; : 406-413, 2019.
Artigo em Inglês | WPRIM | ID: wpr-760061

RESUMO

PURPOSE: To evaluate the effects of idiopathic infantile nystagmus (IN) and bilateral ametropic amblyopia on metabolites in the occipital cortex by magnetic resonance spectroscopy. METHODS: The children included in this prospective study were divided into three groups. Group 1 consisted of 11 patients with idiopathic IN, group 2 consisted of 10 patients with bilateral ametropic amblyopia and group 3 consisted of nine normal children. A single-voxel magnetic resonance spectroscopy examination was performed by placing a region of interest on the occipital cortex of each participant. N-acetyl aspartate (NAA), creatine (Cr) and choline (Cho) concentrations were measured in the occipital cortex. This was followed by calculating and comparing the NAA/Cr and Cho/Cr ratios between the three groups. The Kruskal-Wallis test, Mann-Whitney U-test, and chi-square test were used for statistical analysis. RESULTS: There was no statistically significant difference in NAA/Cr ratios between patients with idiopathic IN and normal children, but there was a statistically significant difference between these groups when Cho/Cr ratios were compared; the ratio was higher in the idiopathic IN group. There were no statistically significant differences in NAA/Cr or Cho/Cr ratios between patients with bilateral ametropic amblyopia and normal children. CONCLUSIONS: Our findings suggest that the neurochemical profile of the occipital cortex is partially affected by idiopathic IN, but not by bilateral ametropic amblyopia.


Assuntos
Criança , Humanos , Ambliopia , Ácido Aspártico , Colina , Creatina , Espectroscopia de Ressonância Magnética , Lobo Occipital , Estudos Prospectivos
3.
Korean Journal of Ophthalmology ; : 167-172, 2019.
Artigo em Inglês | WPRIM | ID: wpr-741313

RESUMO

PURPOSE: To evaluate contrast sensitivity in patients with Behçet's disease (BD) without ocular involvement. METHODS: The study group was composed of 47 BD patients (20 to 50 years of age) who did not have ocular involvement. The control group was composed of 47 normal volunteers who were similar to the study group in terms of age and gender. No participants in this study had any ocular or systemic pathologies except for BD. The contrast sensitivity measurements were performed using the Functional Acuity Contrast Test under photopic conditions, and the results were compared between the two groups. RESULTS: The mean age of the BD patients and control subjects was 34.5 ± 9.7 and 33.2 ± 7.6 years, respectively. The mean disease duration of the BD patients was 5.5 ± 6.4 years. There was a statistically significant decrease at five spatial frequencies (A, 1.5; B, 3; C, 6; D, 2; and E, 18 cycles per degree) in patients with BD compared with control subjects (p < 0.001, p = 0.004, p = 0.002, p < 0.001, and p = 0.001, respectively). CONCLUSIONS: The contrast sensitivity of BD patients without ocular involvement was lower than that of the control group. Further studies seem mandatory to confirm our results.


Assuntos
Humanos , Síndrome de Behçet , Sensibilidades de Contraste , Voluntários Saudáveis , Patologia