Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Adicionar filtros








Intervalo de ano
1.
Anatomy & Cell Biology ; : 72-78, 2022.
Artigo em Inglês | WPRIM | ID: wpr-925386

RESUMO

The purpose of this study was to analyze the accuracy of intra oral scanner (IOS) to confirm the applicability of IOS for the recording and analysis of tooth morphology in forensics. The less damaged mandible specimen with many teeth remaining was scanned three times using three types of intraoral scanners (CS3600, i500, and Trios3). For quantitative comparisons of the scanned images produced by these intraoral scanners, root mean square (RMS) values were computed using a three-dimensional analysis program and a one-way ANOVA was conducted with Tukey HSD (honestly significant difference) as a post-hoc analysis (α=0.05). The repeatability of the full scan data was highest with the i500 (0.14±0.03 mm), and the post-hoc analysis confirmed significant differences between the CS3600 and the i500 outcomes (P-value=0.003). The repeatability of the partial scan data for the teeth in the mandible was highest with the i500 (0.08±0.02 mm), and the post-hoc analysis confirmed significant differences between the CS3600 and the i500 (P-value=0.016). The precision of the full scan data was highest with the i500 (0.16±0.01 mm) but the differences were not statistically significant (P-value=0.091). Meanwhile, the precision of the partial scan data for the teeth in the mandible was highest with the Trios3 (0.22±0.02 mm), but the differences were not statistically significant (P-value=0.762). Considering that the scanning of other areas of the oral cavity in addition to the teeth is important in forensic odontology, the i500 scanner appears to be the most appropriate intraoral scanner for human identification. However, as the scope of oral scanning is generally limited to teeth in the practice of dentistry, additional discussions of how to apply the IOS in forensic odontology are needed. Ultimately, the results here can contribute to the overall discussion of the forensic applicability dental data produced by intraoral scanners.

2.
Korean Journal of Dental Materials ; (4): 147-154, 2018.
Artigo em Coreano | WPRIM | ID: wpr-759667

RESUMO

In this study, we tried to confirm clinically applicable applicability by comparing the difference in 3 point flexural strength and shade of the prosthesis depending on microwave sintering time of dental CAD / CAM zirconia. 3 Point flexural strength specimens (n=30) and shade measurement specimens (n=28) were prepared and sintered at different sintering times. 3 point flexural strength and shade were measured and analyzed by independent t-test (α=0.05). Measurement result of 3 point flexural strength the average of short-term sintering (STS) was 245.47±29.89 MPa, the average of long-term sintering (LTS) was 284.27±31.56 MPa, and there was a statistically significant difference (p 0.05). The 3 point flexural strength of the zirconia restorations fabricated by short time and long time was high in long time sintering. However, other conditions may be required for clinical applications. Since the shade test did not show any significant color difference according to sintering time, it is considered to be sufficient for clinical application.


Assuntos
Micro-Ondas , Próteses e Implantes
3.
Korean Journal of Dental Materials ; (4): 169-178, 2018.
Artigo em Coreano | WPRIM | ID: wpr-759665

RESUMO

This study was conducted to analyze the effects of beverages on tooth corrosion by selecting drinks that are enjoyed by modern people. Drinks were selected for carbonated beverages (Coca Cola), energy drinks (Red Bull), orange juice, beer (Hite) and water (Evian). Bovine tooth was immersed for 1 hour, 24 hours and 48 hours. The root mean square (RMS) values were obtained by scanning the bovine tooth at pre-immersion and immersion time after impression making. Two-way ANOVA, one-way ANOVA, and Tukey-test were used to compare differences between groups (α=0.05). The RMS value tended to increase with longer immersion times in all beverages, and there was a significant difference (p < 0.05) between before immersion-1hr and before immersion-48 hr. The mean of RMS according to the type of beverage was significantly different and there was a significant difference according to the change of immersion time (p < 0.05). In order to prevent tooth corrosion, it is necessary to change the method of ingestion or to reduce the time of ingestion.


Assuntos
Cerveja , Bebidas , Bebidas Gaseificadas , Citrus sinensis , Corrosão , Ingestão de Alimentos , Bebidas Energéticas , Imersão , Métodos , Dente , Água
4.
The Journal of Advanced Prosthodontics ; : 321-327, 2018.
Artigo em Inglês | WPRIM | ID: wpr-742042

RESUMO

PURPOSE: The purpose of this study was to compare the cutting method and the lamination method to investigate whether the CAD data of the proposed inlay shape are machined correctly. MATERIALS AND METHODS: The Mesial-Occlusal shape of the inlay was modeled by changing the stereolithography (STL). Each group used SLS (metal powder) or SLA (photocurable resin) in the additive method, and wax or zirconia in the subtractive method (n=10 per group, total n=40). Three-dimensional (3D) analysis program (Geomagic Control X inspection software; 3D systems) was used for the alignment and analysis. The root mean square (RMS) in the 2D plane state was measured within 50 µm radius of eight comparison measuring points (CMP). Differences were analyzed using one-way analysis of variance and post-hoc Tukey's test were used (α=.05). RESULTS: There was a significant difference in RMS only in SLA and SLS of 2D section (P < .05). In CMP mean, CMP 4 (−5.3±46.7 µm) had a value closest to 0, while CMP 6 (20.1±42.4 µm) and CMP 1 (−89.2±61.4 µm) had the greatest positive value and the greatest negative value, respectively. CONCLUSION: Since the errors obtained from the study do not exceed the clinically acceptable values, the lamination method and the cutting method can be used clinically.


Assuntos
Restaurações Intracoronárias , Métodos , Rádio (Anatomia)
5.
The Journal of Advanced Prosthodontics ; : 312-316, 2015.
Artigo em Inglês | WPRIM | ID: wpr-44183

RESUMO

PURPOSE: This study aimed to present the clinical applicability of restorations fabricated by a new method, by comparing the bond strength of between ceramic powder with different coefficient of thermal expansion and alloys fabricated by Selective laser sintering (SLS). MATERIALS AND METHODS: Fifty Co-Cr alloy specimens (25.0 x 3.0 x 0.5 mm) were prepared by SLS and fired with the ceramic (8.0 x 3.0 x 0.5 mm) (ISO 9693:1999). For comparison, ceramics with different coefficient of thermal expansion were used. The bond strength was measured by three-point bending testing and surfaces were observed with FE-SEM. Results were analyzed with a one-way ANOVA (alpha=.05). RESULTS: The mean values of Duceram Kiss (61.18 +/- 6.86 MPa), Vita VM13 (60.30 +/- 7.14 MPa), Ceramco 3 (58.87 +/- 5.33 MPa), Noritake EX-3 (55.86 +/- 7.53 MPa), and Vintage MP (55.15 +/- 7.53 MPa) were found. No significant difference was observed between the bond strengths of the various metal-ceramics. The surfaces of the specimens possessed minute gaps between the additive manufactured layers. CONCLUSION: All the five powders have bond strengths higher than the required 25 MPa minimum (ISO 9693); therefore, various powders can be applied to metal structures fabricated by SLS.


Assuntos
Ligas , Cerâmica , Incêndios , Pós
6.
The Journal of Advanced Prosthodontics ; : 266-271, 2014.
Artigo em Inglês | WPRIM | ID: wpr-86721

RESUMO

PURPOSE: The purpose of this study was to compare the fracture strength of the metal and the bond strength in metal-ceramic restorations produced by selective laser sintering (SLS) and by conventional casting (CAST). MATERIALS AND METHODS: Non-precious alloy (StarLoy C, DeguDent, Hanau, Germany) was used in CAST group and metal powder (SP2, EOS GmbH, Munich, Germany) in SLS group. Metal specimens in the form of sheets (25.0 x 3.0 x 0.5 mm) were produced in accordance with ISO 9693:1999 standards (n=30). To measure the bond strength, ceramic was fired on a metal specimen and then three-point bending test was performed. In addition, the metal fracture strength was measured by continuing the application of the load. The values were statistically analyzed by performing independent t-tests (alpha=0.05). RESULTS: The mean bond strength of the SLS group (50.60 MPa) was higher than that of the CAST group (46.29 MPa), but there was no statistically significant difference. The metal fracture strength of the SLS group (1087.2 MPa) was lower than that of the CAST group (2399.1 MPa), and this difference was statistically significant. CONCLUSION: In conclusion the balling phenomenon and the gap formation of the SLS process may increase the metal-ceramic bond strength.


Assuntos
Ligas , Cerâmica , Incêndios
7.
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 1062-1068, 1997.
Artigo em Coreano | WPRIM | ID: wpr-147929

RESUMO

From August 1989 to January 1996, a total of 105 cases of bidirectional Glenn operations have been done as the interim stage for the patients with some risk of univentricular correction at Sejong General Hospital. From December 1992, we started the conversion to Fontan operations for them, and 42 cases underwent Fontan-stage operation till February 1996. Their diagnoses were univentricular heart in 19(right ventricular type : 14), tricuspid atresia 11, double outlet of right ventricle 9, and others in 3 cases. The median age of bidirectional Glenn-stage operation was 12.5 months(range 2 months to 8 years) and Fontan-stage operation was at 59.6 months of median age(range 1 year 5 months to 9 year 7 months). The mean waiting interval between the two operations was 33.88+/-17.85 months with a range of 10 months to 6 years 3 months. During the waiting periods, 18 patients developed significant systemic-pulmonary collaterals and/or systemic veno-veno collateral channels. There were 5 hospital deaths after operations due to low cardiac output in 4 and sepsis in one. Most of the Fontan-stage operations were done by the lateral tunneling with Gore-Tex tube graft patch and fenestrated with the size of 2.5~6 mm. All the patients were followed-up(7 months to 4 years 2 months, mean 21.97+/-10.82 months) and there were 5 late deaths(postoperatively 6 months to 2 years) due to thromboembolism in 1, after heart transplantation 1, plastic bronchitis 1, protein loosing enteropathy 1, and pneumonia in 1. Dividing the patients by the waiting interval of 2 years, the early correction to Fontan group (N=16) showed the better results(hospital mortality 1/16, late mortality 1/16, significant collateral development 2/16) compared to the other group(N=26) (4/26, 4/26, 16/26). In conclusion, after the bidirectional Glenn-stage operation successfully got rid of the previous risk factors, we recommand to do the Fontan-stage operation no later than 2 years of interval.


Assuntos
Humanos , Anastomose Cirúrgica , Bronquite , Baixo Débito Cardíaco , Diagnóstico , Técnica de Fontan , Coração , Transplante de Coração , Ventrículos do Coração , Hospitais Gerais , Mortalidade , Plásticos , Pneumonia , Politetrafluoretileno , Fatores de Risco , Sepse , Tromboembolia , Transplantes , Atresia Tricúspide
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA