Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Acta cir. bras ; 30(4): 235-241, 04/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-744275

RESUMO

PURPOSE: To evaluate the morphology, necrotic area and collagen content in skin flaps of rats subjected to hyperbaric oxygenation (HBO). METHODS: Forty adult rats were divided into four groups: GEC - epilated; GE/HBO - epilated subjected to HBO; GER - epilated submitted to skin flap (2 cm in width /8 cm length in the dorsal area) and GER/HBO - epilated, subjected to skin flap and HBO. HBO (2.4 ATA) was performed for two hours during seven consecutive days. In the eighth day, the rats were anesthetized and the skin flaps were removed and separated into three portions, relative to pedicle fixation. The material fixed in 10% formalin was processed for paraffin embedding; sections were stained by H.E and subjected to picrosirius-red method. The slides examined under light microscopy for evaluation of the collagen content in polarized light microscope and ImageLab(r) software (Bio-Rad). RESULTS: The data showed larger area of necrosis and lower levels of collagen in the three regions of the GER group, whereas in the GER/HBO group the collagen content was similar to the GEC and GE/HBO groups. CONCLUSION: Hyperbaric oxygenation reduced the area of necrosis and preserved the morphology and collagen content in skin flaps of rats. .


Assuntos
Animais , Ratos , Colágeno/análise , Oxigenoterapia Hiperbárica/métodos , Transplante de Pele/métodos , Pele/patologia , Retalhos Cirúrgicos/patologia , Retalhos Cirúrgicos/fisiologia , Biópsia , Necrose/patologia , Distribuição Aleatória , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Cicatrização
2.
Acta cir. bras ; 26(3): 235-241, May-June 2011. ilus, tab
Artigo em Inglês | LILACS | ID: lil-583745

RESUMO

PURPOSE: To investigate the effectiveness of fibrin glue (laparoscopic via) into promote the hemostasis of a spleen injury on a heparinized porcine model. METHODS: Eighteen Landrace porcine were submitted to laparoscopic spleen injury and randomly distributed: GHA (heparin plus adhesive), GH (heparin without adhesive) and GS (Sham - without heparin or adhesive). Ten minutes before the surgical procedures a single IV dose (200UI/kg) of heparin sodium was administrated only to groups GHA and GH. In the GHA, adhesive was applied after the mechanical injury and recorded the time until the polymerization and clot formation. RESULTS: No significant differences occurred among the groups (Fisher test) considering the weight and surgery time. The blood amount in the abdominal cavity on GH was significantly higher in comparison to the sham group and especially with the GHA (p<0.004). No significant differences were observed in the body temperature, heart rate, cardiac output, means arterial pressure, pulmonary artery pressure during the experiment. The activated partial thromboplastin time (APTT) was lower in the GHA in comparison to GH (p<0.003). CONCLUSION: The fibrin biological adhesive applied by laparoscopy is effective for hemostasis of minor spleen injury in a porcine model under the effect of anticoagulant drug.


OBJETIVO: Investigar a eficácia da cola de fibrina (via laparoscópica) na hemostasia de uma lesão no baço de porco heparinizado. MÉTODOS: Dezoito suínos Landrace foram submetidos a lesão do baço e distribuídos aleatoriamente: GHA (heparina adesivo), GH (heparina sem adesivo) e GS (Sham - sem heparina ou adesivo). Dez minutos antes dos procedimentos uma dose única (200UI/kg) de heparina sódica (EV) foi administrada nos grupos GHA e GH. A fibrina (GHA) foi aplicada após a lesão e registrado o tempo até a polimerização e formação do coágulo. RESULTADOS: Não houve diferenças significativas entre os grupos (teste de Fisher), considerando o peso e o tempo de cirurgia. A quantidade de sangue na cavidade abdominal de GH foi significativamente maior em comparação ao GS e, especialmente, com o GHA (p<0,004). Não foram observadas diferenças significativas na temperatura corporal, frequência cardíaca, débito cardíaco, pressão arterial ou pressão da artéria pulmonar durante o experimento (20 minutos). O tempo de tromboplastina parcial ativada (TTPA) foi menor no GHA em relação ao GH (p<0,003). CONCLUSÃO: A cola de fibrina biológica aplicada por laparoscopia é eficaz para a hemostasia de lesões no baço menor em um modelo suíno sob o efeito de drogas anticoagulantes.


Assuntos
Animais , Ruptura Esplênica , Suínos/classificação , Baço/anatomia & histologia , Laparoscopia
3.
Rev. bras. ortop ; 44(5): 397-403, set.-out. 2009. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-531472

RESUMO

OBJETIVO: Avaliar a capacidade do adesivo de fibrina em promover a fixação do menisco ao longo de duas, quatro e oito semanas comparando com a técnica convencional de fixação por sutura a tecidos moles. MÉTODOS: 36 meniscos mediais direitos de coelhos preservados a 73ºC negativos por 30 dias foram transplantados para os animais da mesma amostra e fixados com sutura ou cola de fibrina. Após duas, quatro ou oito semanas a aparência dos meniscos e a qualidade da fixação foram verificadas macroscopicamente e avaliadas por um sistema de escores. Os achados foram submetidos a estudo estatístico de análise de variância por postos (p < 0,05 por cento). RESULTADOS: A preservação por ultracongelamento manteve a integridade macroscópica dos meniscos transplantados. Após todos os períodos pós-transplante também não houve redução significante da extensão dos meniscos (p = 0,015). Os meniscos fixados com fibrina mostraram discretas alterações de coloração e rugosidade de superfície. Não houve sinais de rejeição ou infecção em ambos os grupos. A avaliação por escores da fixação pela sutura foi superior (p = 0,015) em todos os períodos (80 por cento de fixação total) do que a fixação promovida pela fibrina (20 por cento de fixação total). CONCLUSÃO: O transplante homólogo do menisco de coelho sofreu diferentes graus de integração ao joelho de acordo com a técnica de fixação; a técnica operatória com sutura aos tecidos moles mostrou-se superior na avaliação de escores em relação à fixação com adesivo de fibrina.


OBJECTIVE: To evaluate the ability of fibrin adhesive in promoting the meniscus fixation within two, four and eight weeks compared to the conventional soft-tissue suture technique. MATERIALS AND METHODS: 36 right medial menisci of rabbits preserved at negative 73º Celsius for 30 days were transplanted to animals of the same sample and fixed with soft-tissue suture or fibrin glue. After 2, 4 or 8 weeks, the appearance of the menisci and the quality of fixation were macroscopically checked and evaluated by a scoring system. The findings were subjected to the statistical study of variance analysis (p < 0.05 percent). RESULTS: The deep-frozen meniscus preservation maintained the integrity of the meniscus transplant, and, macroscopically, there was no significant reduction of the length of the meniscus in all post-transplant periods (p = 0.015). The menisci fixed with fibrin showed slight changes in color and surface roughness. There were no signs of rejection or infection in both groups. Suture fixation scoring was superior (p = 0.015) in all periods (80 percent of total fixation) as compared to the setting promoted by fibrin (20 percent of total fixation). CONCLUSION: The homologous transplantation of the meniscus of rabbits experienced various degrees of integration to the knee according to the fixation method; the surgical soft tissues suturing technique was shown to be superior in the evaluation of scores compared to the fixation with fibrin adhesive.


Assuntos
Animais , Coelhos , Adesivo Tecidual de Fibrina , Meniscos Tibiais/transplante
4.
Acta cir. bras ; 23(4): 384-390, July-Aug. 2008. ilus
Artigo em Inglês | LILACS | ID: lil-486177

RESUMO

PURPOSE: To develop a project of hyperbaric chamber that allows its safe and reliable use in veterinary and animal experimentation. METHODS: Based on the technical specifications for the construction of hyperbaric chambers for human beings, it has been developed a design of a chamber with dimensions and characteristics for the use of a midsize animal, (dog or pig), as well as a multiple chamber for the use in small animals (mice, rats, hamsters, rabbits or cats). The technical specifications allowed that the chamber could be used both for veterinary use and for use in experiments on Health Sciences. RESULTS: A chamber with the following characteristics was built: ASTM A36 steel for the manufacture of the master cylinder and rear cover; front door built in 5052 aluminum; internal diameter of 50.5 cm and 83.0 cm in length; weight 160Kg and internal area of 150cm³; internal space to accommodate 2 acrylic baskets; 150mm high, 280mm wide and 690mm in length. It was capable of supporting a maximum of hydrostatic pressure test of 3.0 to 4.0 BAR ACT and maximum working pressure of 2.0 BAR or 3.0 ACT; equipped with security devices and valves that triggers with load of 2.2 BAR or 3.2 ACT. Tests for engineering and biological use on animals showed the effectiveness of the device. CONCLUSION: The development of the project enabled the construction of a hyperbaric chamber with security features and reliability comparable to those required by the legal and technical specifications of a hyperbaric chamber human use.


OBJETIVO: Desenvolver um projeto de câmara hiperbárica que permita o seu uso seguro e confiável em veterinária e em animais de experimentação de pequeno e médio porte. MÉTODOS: Baseados em especificações técnicas de construção de câmaras hiperbáricas de seres humanos, foi desenvolvido uma adaptação de projeto de uma câmara com dimensões e características para uso em animal de médio porte (cão ou porco), assim como câmara múltipla para animais de pequeno porte (camundongos, ratos, hamsters, coelhos ou gatos). O atendimento às especificações técnicas deve permitir a sua utilização tanto para uso veterinário quanto para uso em experimentação em Ciências da Saúde. RESULTADOS: Uma câmara com as seguintes características foi construída: aço ASTM A36 para a confecção do cilindro principal e tampo traseiro, tampo frontal (porta) construído em alumínio 5052, diâmetro interno de 50,5cm e 83,0cm de comprimento; peso de 160Kg e espaço interno de 150cm³; espaço para acomodar 2 cestas de acrílico de 150mm de altura, 280mm de largura e 690mm de comprimento; capacidade para suportar um máximo de pressão hidrostática teste de 3,0BAR ou 4,0 ACT e uma pressão máxima de trabalho de 2,0 BAR ou 3,0 ACT; equipado com dispositivos e válvulas de segurança que disparam com carga de 2,2 BAR ou 3,2 ACT. Os testes de engenharia e de uso biológico com animais mostraram a efetividade do equipamento. CONCLUSÃO: O desenvolvimento do projeto permitiu a confecção de uma câmara hiperbárica com características de segurança e confiabilidade comparável às exigidas pelas especificações técnicas e legais de uma câmara para tratamento hiperbárico.


Assuntos
Animais , Oxigenoterapia Hiperbárica/instrumentação , Oxigenoterapia Hiperbárica/veterinária , Animais de Laboratório , Desenho de Equipamento , Segurança de Equipamentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA