Chinese Journal of Laboratory Medicine ; (12): 699-701, 2008.
Artigo em Chinês | WPRIM | ID: wpr-383801

RESUMO

Objective To establish an early,simple and rapid colloidal gold strip method for the detection of IgM against hantavirus nucleocapsid protein in patients with hemorrhagic fever with renal syndrome(HFRS).Methods Purified recombinant Hantavirus nucleoprotein(rNP)was labeled by colloidal gold particles and then sprayed and fixed on fiberglass membrane as the combination pad.Anti-Human IgM(μ-chain specific)antibody produced in goat was fixed in the detection area,and mouse antihantavirus antibody was fixed in the quality control area.Both of them were on nitrocellous membrane strip in tandem.Together with a specimen pad ahead.The conbination pad and the nitrocellous membrane were assembled into a test strip.The colloidal gold strip assay was compared with ELISA for evaluation of specificity and sensitivity.Results The colloidal gold strip tests showed positive in the serum samples from 50 cases of HFRS which was clinically diagnosed and then verified by ELISA within 10-15 minutes.Whereas 30 serum samples of healthy donors have tested negative.Conclusions Our new colloidal gold immunochromatographic test strip method was well concordant with the ELISA assay,but the former was more raoid and simole.It could be used primary medical services.