Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
CES odontol ; 33(2): 72-85, jul.-dic. 2020. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1285752

RESUMO

Resumen Introducción y objetivo: La fricción en la ortodoncia se produce por contacto directo entre el bracket, el alambre y la ligadura. La fricción reduce la eficiencia en los tratamientos de ortodoncia. Esta investigación comparó la resistencia a la fricción entre los brackets cerámicos convencionales y los brackets cerámicos de autoligado pasivos utilizando un método de elementos finitos (MEF). Materiales y métodos: Se realizó un total de 810 deslizamientos, combinando brackets cerámicos convencionales y autoligados, y alambres de ortodoncia de acero inoxidable, níquel-titanio y de la aleación β-titanio de 0.016 pulgadas, 0.017x0.025 pulgadas y 0.019 x0.025 pulgadas. La media máxima de resistencia a la fricción estática (MRF) se comparó entre las diferentes combinaciones de brackets, alambre, ligadura y angulación del bracket de 0 °, 7 ° y 13 °. Resultados: Las variables con el comportamiento de fricción más alto fueron 13 °, aleación β titanio, 0.017x0.025 pulgadas, y brackets cerámicos convencionales con ligaduras elásticas. Conclusión: MEF es una alternativa adecuada para la predicción de la MRF en varias combinaciones de brackets, alambres, ligaduras y angulaciones. El método permitió definir una menor resistencia a la fricción para los brackets de autoligado, así como una relación directa entre el aumento del ángulo y el área de contacto entre el bracket y el alambre, con valores más altos de resistencia al deslizamiento. Se estableció que un alambre de mayor calibre no implica un área de mayor contacto con el bracket.


Abstract Introduction and objective: Friction in orthodontics is produced by direct contact between the bracket, the wire, and the ligature. Friction reduces efficiency in orthodontic treatments. This research aims to compare the frictional resistance between conventional ceramic brackets and passive self-ligating ceramic brackets using a finite element method (FEM). Materials and methods: A total of 810 slidings were performed, combining conventional and self-ligating ceramic brackets, and stainless steel, nickel-titanium, and b-titanium alloy orthodontic wires of 0.016inch, 0.017x0.025inch, and 0.019x0.025inch. The maximum static frictional resistance (MSFR) mean was compared between the different brackets, wire, ligature, and bracket angulation combinations of 0°, 7°, and 13°. Results: The variables with the highest frictional behavior were 13°, b-titanium alloy, 0.017x0.025inch, and conventional ceramic brackets with an elastic ligatures. Conclusion: FEM is an adequate alternative for the prediction of MSRF in a various brackets, wire, ligating, and angulation combinations. The method allowed defining lower frictional resistance for self-ligating brackets, as well as a direct relationship between the increase in the angle and contact area between bracket and wire, with higher values of sliding resistance. It was established that a larger wire size does not imply a higher area of contact with the bracket.


Resumo Introdução e objetivo: O atrito na ortodontia é produzido pelo contato direto entre braquetes, fios e ligaduras. O atrito reduz a eficiência em tratamentos ortodônticos. Esta pesquisa tem como objetivo comparar a resistência ao atrito entre braquetes cerâmicos convencionais e braquetes cerâmicos autoligáveis paacero inoxidableivos usando um método de elementos finitos (MEF). Materiais e métodos: Foram realizados 810 deslizamentos de terra, combinando braquetes de cerâmica convencionais e autoligáveis e fios ortodônticos de aço inoxidável, liga de níquel-titânio e β-titânio em 0,016 polegadas, 0,017 x 0,025 polegadas e 0,019 0,025 polegadas. A máxima resistência média ao atrito estático (MRF) foi comparada entre as diferentes combinações de braquetes, fios, ligaduras e angulações de braquetes de 0 °, 7 ° e 13 °. Resultados: As variáveis com maior comportamento de atrito foram 13 °, liga β-titânio, 0,017x0,025 polegadas e braquetes cerâmicos convencionales com ligadura elástica. Conclusão: MEF é uma alternativa adequada para previsão de MRF em várias combinações de braquetes, fios, ligaduras e angulações. O método permitiu definir uma menor resistência ao atrito para braquetes autoligáveis, bem como uma relação direta entre o aumento do ângulo e a área de contato entre os braquetes e o fio, com maiores valores de resistência ao escorregamento. Foi estabelecido que um tamanho de cabo maior não implica uma área de contato mais alta com o suporte.

2.
Investig. segur. soc. salud ; 20(1): 11-20, 2018. tab
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1051746

RESUMO

La leptospirosis es una zoonosis con una amplia distribución. Su agente etiológico, Leptospira, afecta a los seres humanos y a más de 160 especies animales y se encuentra en el ambiente. Esto ha llevado a que se incentive su manejo desde la intersectorialidad; por lo tanto, el objetivo del presente artículo es presentar una experiencia exitosa que evidencia la necesidad de realizar un trabajo integrado desde el diagnóstico, que permita fortalecer la vigilancia y el control de la leptospirosis. Para ello, se hace un análisis sobre la situación general del plan nacional y distrital de salud pública, la importancia de la leptospirosis como enfermedad emergente y reemergente y el panorama de los efectos que ocasiona la globalización, y se argumenta la necesidad de un enfoque multisectorial para esta zoonosis. Como resultado de la experiencia, se evidencian los logros obtenidos dentro del marco del proyecto Detección de Leptospira y distribución de serogrupos en humanos, bovinos y agua de la Sabana de Bogotá, cuyos resultados muestran la necesidad de un manejo integrado. Este acercamiento desde la integralidad permitirá el fortalecimiento de los sistemas diagnósticos para leptospirosis, al ampliar el conocimiento del agente etiológico y de la enfermedad en el contexto tropical


Leptospirosis is zoonosis with highest distribution. Leptospira spp is etiological agent affects humans, more than 160 animal species and is found in the environment. This has led to its management incentive from intersectoriality; therefore, the aim of this article is to present a successful experience that demonstrates the need for an integrated approach from diagnosis to strengthen surveillance and control of leptospirosis work. To do an analysis of the overall situation of national and district public health, the importance of leptospirosis as emerging and re-emerging disease, the vision of the effects caused by globalization and the need for a multisectoral approach argues for this zoonosis. Because of the experience achievements within the framework of "Detection of Leptospira and distribution of serogroups in humans, cattle and water from the savannah of Bogota" project whose results show the need for an integrated management are evident. This approach from completeness, allow the strengthening of diagnostic systems for leptospirosis expanding knowledge of the etiologic agent and disease in the tropical context


A leptospirose é uma zoonose com distribuição larga, seu agente etiológico Leptospira afeta a humano, mais de 160 espécies animais e é encontrado no meio ambiente. Isto levou a um incentivo para sua gestão a partir da intersetorialidade; portanto, o objetivo deste artigo é apresentar uma experiência bem sucedida que demonstre a necessidade de realizar um trabalho integrado a partir do diagnóstico que permita fortalecer a vigilância e o controle da leptospirose. Foi realizada uma análise da situação geral do plano nacional e distrital de saúde pública, da importância da leptospirose como doença emergente e reemergente, da perspectiva dos efeitos que causam globalização e da necessidade de uma abordagem multissetorial para essa zoonose. como resultado da experiência, são mostradas as conquistas obtidas no âmbito do projeto "Detecção de Leptospira e Distribuição de Serogrupos em Humanos, Bovinos e Água da Savana de Bogotá", cujos resultados mostram a necessidade de um manejo integrado. Esta abordagem do integral, permitirá o fortalecimento dos sistemas de diagnóstico da leptospirose, ampliando o conhecimento do agente etiológico e da doença no contexto tropical.


Assuntos
Humanos , Masculino , Feminino , Bovinos , Leptospira , Leptospirose , Organização e Administração , Saúde Pública , Epidemiologia , Colaboração Intersetorial , Diagnóstico
3.
Rev. Fac. Odontol. Univ. Antioq ; 28(1): 34-53, July-Dec. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-957226

RESUMO

ABSTRACT Introduction: with the purpose of providing additional details on the selection of retainer type, this study sought to assess the stability of dental and occlusal position during retention phase using two types of retainers in individuals with no remnant growth who completed orthodontic treatment at the Universidad de Antioquia School of Dentistry, Universidad CES, and in private practice in Medellín in 2011. Methods: this was a controlled clinical study with a sample of 47 patients aged 15 to 45 years, randomly selected into two treatment groups: 22 patients with Essix retainer and 25 patients with Hawley plate in both arches. Cephalometric X-rays and study models were taken on all patients at baseline and six months later with monthly clinical evaluations. Results: the clinical and radiographic results showed significant differences in some tooth rotations in terms of upper intercanine distance and molar relationship, but overall there were no statistically significant differences between both retainers in the three space planes. Conclusion: there were no statistically significant differences between the retainers in a six-month evaluation period.


RESUMEN Introducción: con el propósito de ofrecer mayor evidencia sobre la selección del tipo de retenedor, este estudio pretendió evaluar la estabilidad de la posición dentaria y oclusal durante el tratamiento de retención con dos tipos de retenedores en individuos sin crecimiento remanente que finalizaron tratamiento ortodóncico en la Facultad de Odontología de la Universidad de Antioquia, de la Universidad CES y en la práctica privada en Medellín en el año 2011. Métodos: se hizo un ensayo clínico controlado con una muestra de 47 pacientes con edades entre 15 y 45 años, divididos aleatoriamente en dos grupos de tratamiento: 22 pacientes con retenedor tipo Essix y 25 pacientes con placa de Hawley en ambos arcos. A todos los pacientes se les tomó radiografía cefálica lateral y modelos de estudio, al inicio y seis meses después, y se hizo evaluación clínica mensual. Resultados: los resultados clínicos y radiográficos mostraron diferencias significativas en algunas rotaciones dentarias, en la distancia intercanina superior y en la relación molar, pero en general no se encontraron diferencias estadísticamente significativas entre los dos retenedores en los tres planos del espacio. Conclusión: no se encontraron diferencias estadísticamente significativas entre los retenedores en una evaluación a seis meses.


Assuntos
Oclusão Dentária , Retenção de Dentadura , Contenções Ortodônticas , Arco Dental
4.
Acta odontol. latinoam ; 29(2): 130-136, 2016. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-834217

RESUMO

The aim of this study was to compare frictional resistance among conventional, passive and active selfligating brackets using Finite Elements Analysis (FEA). Seventynine (79) slide tests were performed by combining an upper first bicuspid conventional bracket, 0.018” stainless steel wires and 0.010” ligature by means of an INSTRON 3345 load system to obtain average maximum static frictional resistance (MSFR). This value was compared to the FR (frictional resistance) obtained by simulation of a slide of the same combination by FEA following conventional bracket modeling by means of Computer Aided Design (CAD). Once the FEA was validated, bracket CADs were designed (upper right first bicuspid conventional, active and passive selfligating bracket) and bracket properties calculated. MSFR was compared among conventional, active and passive selfligating brackets with different alloys and archwire cross sections such as 0.018”, 0.019” x 0.025”and 0.020” x 0.020”. Passive selfligating brackets had the lowest MSFR, followed by conventional brackets and active selfligating brackets. In conventional brackets, a 0.018” archwire produced a linear pattern of stress with maximum concentration at the center. Conversely, stress in 0.020 x 0.020” and 0.019 x 0.025” archwires was distributed across the width of the slot. The highest normal forces were 1.53 N for the 0.018” archwire, 4.85 N for the 0.020 x 0.020” archwire and 8.18 N for the 0.019 x 0.025” archwire. Passive selfligating brackets presented less frictional resistance than conventional and active selfligating brackets. Regardless of bracket type, greater contact area between the slot and the archwire and the spring clip increased frictional resistance.


El objetivo de este estudio fue comparar la resistencia friccional entre brackets convencionales, de autoligado pasivo y activo por medio del método de elementos finitos (MEF). Se realizaron setenta y nueve (79) deslizamientos combinando brackets convencionales de primer bicúspide superior con arcos de acero de 0,018” y ligadura metálica de 0,010” en una máquina INSTRON 3345, obteniendo el promedio de la resistencia estática máxima (REM). Este valor fue comparado con la resistencia friccional obtenida por simulación de un deslizamiento de la misma combinación por medio de MEF previo diseño asistido por computador (CAD) del bracket convencional. Una vez se validó MEF, se realizaron diseños CAD de los brackets (convencional, autoligado activo y pasivo de primer bicúspide superior derecho) y cálculos de sus propiedades. Se realizó una comparación entre brackets convencionales, brackets de autoligado activo y pasivo con diferentes aleaciones y secciones cruzadas de alambre 0.018”, 0.019” x 0.025” y 0.020” x 0.020”. Los brackets de autoligado pasivo mostraron la menor REM, seguidos de los brackets convencionales y finalmente los brackets de autoligado activo. En los brackets convencionales, el arco de 0,018” produjo un patrón lineal de stress en el fondo de la ranura, con su máxima concentración en el centro. Por el contrario, los arcos de 0.020” x 0.020” y 0.019 x 0.025” tuvieron una distribución de esfuerzos a través del ancho de la ranura. La mayor fuerza normal en los brackets convencionales fue para el arco 0.019”x 0.025” (8.18N), seguido por el arco 0.020 x 0.020” (4.85N) y finalmente el arco 0.018” (1.53N). Los brackets de autoligado pasivo presentaron menos resistencia friccional que los brackets convencionales y autoligado activo respectivamente. Independiente del tipo de bracket, una mayor área de contacto entre la ranura del bracket y el arco, y el spring clip aumentaron la resistencia friccional.


Assuntos
Fricção , Braquetes Ortodônticos , Fios Ortodônticos , Ligas Dentárias/química , Desenho Assistido por Computador/métodos , Análise de Elementos Finitos , Interpretação Estatística de Dados
5.
Rev. Fac. Odontol. Univ. Antioq ; 23(2): 268-291, jun. 2012. graf, tab
Artigo em Espanhol | LILACS | ID: lil-641192

RESUMO

Introducción: este estudio pretende comparar clínica y radiográficamente los efectos producidos por el distalizador péndulo en dos formas de anclaje: esquelético y dentoalveolar, en pacientes con maloclusiones clase II de la Facultad de Odontología de la Universidad de Antioquia. Métodos: se hizo un estudio preexperimental comparativo. Se utilizó una muestra de 19 pacientes con edades entre los 15y 26 años, divididos en dos grupos: 9 pacientes tratados con péndulo de anclaje esquelético y 10 con péndulo de anclaje dentoalveolar. A todos los pacientes se les tomaron radiografías cefálicas laterales y modelos de estudio, al inicio y al final del tiempo de evaluación (6 meses). Resultados: los resultados clínicos y radiográficos muestran diferencias significativas en los efectos producidos a nivel de incisivos y molares. El péndulo con anclaje dentoalveolar presentó en promedio proinclinación de los incisivos de 4°, mientras que el péndulo conanclaje esquelético no mostró variación. En cuanto al efecto producido en los molares se observó mayor cantidad de distalación por inclinación (14,1°) en el péndulo con anclaje dentoalveolar que en el péndulo con anclaje esquelético (7,34°). Conclusiones: el péndulobajo las dos modalidades de anclaje mostró ser un dispositivo eficaz para distalar molares, sin embargo es importante tener en cuenta el efecto que se quiere producir sobre los incisivos, pues cada uno produce resultados diferentes.


Introduction: This study seeks to clinically and radiographically compare the effects produced by the distalization pendulum in both skeletal and dentoalveolar anchorage, in patients with Class II malocclusions at the Universidad de Antioquia’s School of Dentistry. Methods: a pre-experimental comparative study was carried out on a sample of 19 patients aged 15-26 years, divided into two groups:9 patients treated with bone anchorage pendulum and 10 with dentoalveolar anchorage pendulum. Lateral cephalic radiographs of each patient were taken and study models were done at the beginning and the end of evaluation period (6 months). Results: both clinical and radiographic results show significant differences in the effects produced at the incisors and molars. The pendulum with dentoalveolar anchorage presented an average incisor proclination of 4°, while the pendulum with skeletal anchorage showed no variation. Concerning the effect produced in molars, a greater amount of distalization as a result of inclination was observed in the pendulum with dentoalveolar anchorage (14.1°) in comparison to the one with skeletal anchorage (7.34°). Conclusions: with both modalities, the pendulum provedto be effective for molar distalization; nevertheless, it is important to bear in mind the desired effect on the incisors, as each technique produces different results.


Assuntos
Humanos , Implantes Dentários , Ortodontia
6.
Rev. Fac. Odontol. Univ. Antioq ; 21(1): 16-32, Dic. 2009. tab, graf
Artigo em Espanhol | LILACS | ID: lil-540604

RESUMO

Introducción: esta investigación pretende determinar los cambios radiográficos y clínicos obtenidos con el distractor de García® en cuanto a sus efectos craneofaciales, dentales y de cosmética facial en pacientes con mordida abierta anterior. Métodos: se hizo un estudio clínico prospectivo cuasi experimental en nueve sujetos dos hombres siete mujeres, siete de ellosen crecimiento con un promedio de edad de 11,7 años y 2 adultos con un promedio de edad de 30 años; en quienes cuales se obtuvieron radiografías cefálicas laterales al inicio, tercero y sexto mes de tratamiento. El efecto clínico se valoró mensualmentemidiendo con un calibrador digital Discover® la sobremordida vertical y horizontal. En el análisis estadístico se obtuvieron medidas descriptivas y se utilizó la prueba ANOVA de medidas repetidas para determinar los cambios en el tiempo, con nivel de significancia de 0,05. Resultados: los hallazgos muestran en los pacientes en crecimiento, a nivel craneofacial incremento en el ángulo goniaco, a nivel dentoalveolar incremento en la sobremordida vertical acompañada con disminución en la sobremordidahorizontal explicada por intrusión del molar superior y retroinclinación de incisivos superiores e inferiores, y a nivel facial disminución en el ángulo de la convexidad de tejidos blandos. Conclusiones: el aparato distractor de García utilizado durante seis meses en los pacientes en crecimiento de esta muestra mejoró la mordida abierta, tanto por intrusión de molares superiores como por retroinclinación de incisivos superiores e inferiores.


Introduction: this study aims to determine radiographic and clinical changes obtained with the Garcia’s distractor appliance® and its craniofacial, dental and facial cosmetic effects in patients with anterior open bite. Methods: a prospectiveclinical quasi-experimental study in 9 subjects, 2 men and 7 women, 7 of them in a phase of active growth with an average age of 11.7 years and 2 adults with an average age of 30 years, in which cephalic radiographs were obtained at the beginning, thirdand sixth month of treatment. The clinical effect was assessed by measuring monthly the overbite and overjet with a digital gauge Discover®. In the statistical analysis, descriptive measures were obtained using ANOVA test for repeated measurements to determine changes over time, with a level of significance of 0.05. Results: the radiographic findings showed an increase in the goniac angle in the growing patients; also, an increase in the overbite and a decrease in the overjet were observed, these changes are explained by the intrusion of the upper molars and retro inclination of the upper and lower incisors; facially, there was a decrease in the angle of convexity in the soft tissues. Conclusions: the Garcia’s distractor appliance® used for a period of six month in growingpatients improved the open bite by intrusion of upper molars and retro inclination of upper and lower incisors.


Assuntos
Humanos , Mordida Aberta , Aparelhos Ortodônticos , Estética Dentária
7.
Rev. Fac. Odontol. Univ. Antioq ; 13(2): 79-85, ene-.jun. 2002. ilus
Artigo em Espanhol | LILACS | ID: lil-347374

RESUMO

El manejo ortodóncico de caninos retenidos requiere de una secuencia adecuada, con base en el diagnóstico. La biomecánica ortodóncica utilizada debe hacer un control de la zona de acción y de la zona de reacción. Varias técnicas son empleadas para tal objetivo: arco completo, técnica segmentaria, ansas en caja, resorte tipo ballesta y magnetos. Lo más importante es que el diagnóstico conduzca a orientar las prioridades como guía para el adecuado manejo interdisciplinario


Assuntos
Dente Canino , Ortodontia Corretiva , Dente Impactado , Aparelhos Ortodônticos , Aparelhos Ortodônticos Removíveis , Dente Pré-Molar , Fenômenos Biomecânicos , Dente Canino , Ligas Dentárias , Magnetismo , Maxila , Desenho de Aparelho Ortodôntico , Fios Ortodônticos , Equipe de Assistência ao Paciente , Contenções Ortodônticas , Braquetes Ortodônticos , Técnicas de Movimentação Dentária , Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA