Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Tipo de estudo
Intervalo de ano
1.
Journal of Chinese Physician ; (12): 383-386, 2015.
Artigo em Chinês | WPRIM | ID: wpr-474637

RESUMO

Objective To investigate the efficacy of ganciclovir in viral keratitis and its influence on serum related indicators.Methods Patients with viral keratitis from May 2012 to December 2013 in our hospital were randomly divided into control and observation groups, each group had 62 cases.Patients in control group were treated with acyclovir eye drops, and those in observation group were treated with ganci-clovir ophthalmic gel.The difference in efficacy of two groups was compared.The levels of serum inflamma-tory cytokines of interleukin-2 (IL-2), IL-4, IL-6, IL-8, tumor necrosis factor-α(TNF-α), and interferon-γ( IFN-γ) of two groups before and after treatment were compared, the serum levels of nitric oxide ( NO) , super oxide dismutase (SOD), malondialdehyde (MDA), C3, and C-reactive protein (CRP) were been compared.Results The pain relief time and corneal healing time of observation group [(3.41 ±0.89)d and (4.02 ±1.11)d] were all shorter than control group [(4.52 ±1.21)d and (6.30 ±1.45)d].The cure rate and total effective rate of observation group were 58.06%and 90.32%, respectively.It was sig-nificantly higher than control group ( P <0.05).After 3 and 7 days of treatment, the serum levels of IL-4, IL-6, and IL-8 were lower than control group, and IL-2, and IFN-γwere higher than control group (33.87%and 82.26%) ( P <0.05).After 3 and 7 days of treatment, the serum levels of NO and MDA were lower than control group, and SOD, C3, and CRP were higher than control group ( P <0.05).Con-clusions Ganciclovir has a better efficacy than acyclovir for viral keratitis, and can effectively adjust the serum levels of related indicators.

2.
Chinese Journal of Medical Instrumentation ; (6): 103-107, 2011.
Artigo em Chinês | WPRIM | ID: wpr-330508

RESUMO

<p><b>OBJECTIVE</b>Design a convenient and stable eye refractometer based on the theory of blur circle.</p><p><b>METHODS</b>Analyze the retinal blur circle in both Emsly reduced eye model and Liou & Brennan 1997 eye model by ZEMAX. Design the coefficients including PD (pupil diameter) and NO' (length between node point and fovea) with the purpose of improving the accuracy. At last, compare the clinical optometry data from this refractor with the data obtained from optometry hospital in Wenzhou.</p><p><b>RESULTS</b>The blur circle diameters are nearly the same in both reduced eye model and the Liou & Brennan 1997 eye model. With the PD = 4 mm and NO' = 20 mm, the refractor shows a fine accuracy in optometry. The paired t test shows that the myopia group and the astigmatism axial direction group have no statistical difference between the data from the blur circle refractor and the hospital (P > 0.05), while the astigmatism degree group has the result of P = 0.41 which may be caused by the poor cooperation of pediatric patients. 80% of the astigmatism degree data differ from the data from the hospital in less than 0.75D.</p><p><b>CONCLUSION</b>The blur circle refractor, with the features of convenience and fine accuracy, is promised to be a new style of refractometer in the future.</p>


Assuntos
Humanos , Astigmatismo , Desenho de Equipamento , Fóvea Central , Modelos Estatísticos , Miopia , Oftalmoscópios , Oftalmoscopia , Refração Ocular , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA