International Journal of Radiation Research. 2016; 14 (4): 313-321
em Inglês | IMEMR | ID: emr-187630

RESUMO

Background: this study presents patient specific and organ dose estimation in computed tomography [CT] imaging of thorax directly from patient CT image using Monte Carlo simulation. Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose


Materials and Methods: EGSnrc /BEAMnrc Monte Carlo [MC] System was used for CT scanner simulation and DOSXYZnrc was used in order to produce patient specific phantom and irradiation of photons to phantom in step and shoot mode [axial mode]. In order to calculate patient thorax organ dose, patient CT image of thorax as voxelized phantom was divided to a 64x64x20 matrix and 6.25 x 6.25 x 6.25 mm[3] voxel size and this phantom was imported to DOSXYZnrc code. MC results in unit of Gy/particle were converted to absorbed dose in unit of mGy by a conversion factor [CF]. We calculated patient thorax organ dose in MC simulation from all irradiated slices, in 120 kV and 80 kV photon energies


Results: effective dose was obtained from organ dose and organ weighting factor. Esophagus and spinal cord received the lowest, and bone received the highest dose. In our study, effective dose in CT of thorax was 7.4 mSV and 1.8 mSv in 120 and 80 kV, respectively


Conclusion: the results of this study might be used to provide the actual patient organ dose in CT imaging and calculation of real effective dose based on organ dose

2.
International Journal of Radiation Research. 2014; 12 (3): 249-256
em Inglês | IMEMR | ID: emr-149949

RESUMO

Physical wedges are still widely used as beam modifiers in external beam radiotherapy. However the presence of them in the beam trace may cause beam hardening which may not be considered in many treatment planning systems. The aim of this study is to investigate the beam hardening effect generated by physical wedges via different beam quality indexes as photon spectrum, half value layer, mean energy and tissue-phantom ratio. The effect of physical wedges on the photon beam quality of a 6-18MV Varian 2100C/D accelerator was studied with the BEAMnrc Monte Carlo code. Good agreements were obtained between measured and calculated depth doses and beam profiles for open and wedged photon beams at both energies. It was noticed that for 6 MV photon beams, physical wedges have more significant effects on beam quality than for 18 MV. Also it was obtained that at 18 MV photon beam as the wedge angle increased, the effect of wedge on beam quality becomes reversed and beam softening occurred. According to these results, it is recommended that beam hardening and softening of physical wedges should be considered in treatment planning systems in order to increase the accuracy in dose delivery