Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. colomb. anestesiol ; 46(supl.1): 3-7, Dec. 2018. tab, graf
Artigo em Inglês | LILACS, COLNAL | ID: biblio-959820

RESUMO

Abstract Introduction: Cosmetic plastic surgery interventions are usually associated with significant postoperative pain. As they are outpatient procedures, analgesic management is limited mostly to oral medication, resulting in suboptimal pain control, one of the most frequent complaints of patients undergoing these surgical procedures. Elastomeric pumps have been studied for continuous infusion of intravenous analgesics in other types of surgeries associated with significant pain. Objective: The main objective of this study was to evaluate postoperative pain control in adult patients who underwent mammoplasty, abdominoplasty, liposuction, or combined procedures using elastomeric pumps for postoperative analgesic management in continuous intravenous infusion. Materials and methods: A prospective sample of 100 patients who accepted postoperative pain management was collected. Satisfaction was evaluated using a survey, and pain control was assessed on postoperative days 1,3, and 5, and a determination of adverse reactions associated with analgesia using this device was also assessed. Results: Optimal pain control and a satisfaction greater than 90% were observed from the first postoperative day of the intervention. Conclusion: We recommend this analgesic strategy based on evidence of excellent postoperative ambulatory pain control.


Resumen Introducción: La cirugía plástica estética se caracteriza porque generalmente son intervenciones que originan un importante dolor posoperatorio, al ser procedimientos ambulatorios, el manejo analgésico se limita en la mayoría de las ocasiones a medicación vía oral, la que genera un control subóptimo del dolor, siendo una de las quejas más frecuentes de los pacientes sometidos a estas cirugías. Desde hace algún tiempo se han estudiado las bombas elastoméricas para la infusión continua de analgésicos intravenosos, con el propósito de controlar el dolor posoperatorio en otros tipos de cirugías con importante potencial doloroso. Objetivo: El objetivo principal de este estudio fue evaluar el control del dolor posoperatorio en pacientes adultos, quienes se sometieron a mamoplastia, abdominoplastia, liposucción o combinaciones de estas, con el uso de bombas elastoméricas para el manejo analgésico posoperatorio en infusión intravenosa continua. Materiales y métodos: Se recogió una muestra prospectiva de 100 pacientes quienes aceptaron el manejo del dolor posoperatorio, en quienes se evaluó por medio de una encuesta la satisfacción y el control del dolor de los pacientes al día 1, día 3 y día 5 posoperatorio, además si se presentaron reacciones adversas generadas por la analgesia aplicada a través de este dispositivo. Resultados: Se encontró un óptimo control del dolor y una satisfacción mayor del 90% desde el 1° día posoperatorio de la intervención realizada. Conclusiones: Recomendamos esta estrategia analgésica ya que se evidenció un excelente control del dolor posoperatorio ambulatorio.


Assuntos
Humanos
2.
Rev. colomb. anestesiol ; 46(supl.1): 21-25, Dec. 2018. tab, graf
Artigo em Inglês | LILACS, COLNAL | ID: biblio-959823

RESUMO

Abstract Introduction: Airway management in children is one of the challenges faced by physicians in the different care settings. Unlike the adult population, there is no standard-of-reference device for blind intubation in pediatrics. Our group has already conducted a case series study using the I-Gel device for this purpose, but with no acceptable rates of blind intubation. As part of our search for an appropriate device for this purpose, we examined the use of the Air-Q which comes in pediatric sizes but lacks studies for blind intubation in this population. Objective: The main objective of this study was to assess the percentage of successful blind tracheal intubations through the Air-Q supraglottic device. Materials and methods: Prospective sample of 45 pediatric patients weighing between 7 and 50 kg. Besides assessing the percentage of successful blind tracheal intubations, sealing pressures, and fiberoptic visualization through the device were also evaluated and reported, together with the complications associated with the procedure. Results and conclusion: The overall percentage of blind intubation through the Air-Q mask in this study was 55.5%, found to be not acceptable to warrant a recommendation of use for blind intubation; on the other hand, ideal fiberoptic visualiza tion was acceptable, making this method advisable for fiberoptic-guided intubation through the supraglotting device.


Resumen Introducción: El manejo de la vía aérea en el niño hace parte de los desafíos a los cuales debe enfrentarse el médico en los diferentes servicios de atención. A diferencia de la población adulta, en pediatría no existe un dispositivo estándar de referencia para la intubación a ciegas; nuestro grupo ya realizo una serie de casos con el dispositivo I-gel para este propósito, el cual no mostró tasas aceptables de intubación a ciegas; buscando un dispositivo idóneo para este fin, se plantea el dispositivo Air-Q el cual viene en tamaños pediátricos y no tiene estudios en esta población para intubación a ciegas. Objetivo: El objetivo principal de este estudio fue evaluar el porcentaje de éxito en la intubación traqueal a ciegas a través del dispositivo supraglótico Air-Q. Materiales y métodos: Se recogió una muestra prospectiva en una población pediátrica de 45 pacientes con peso entre 7 y 50Kg, además de evaluar el porcentaje de éxito de la intubación traqueal a ciegas, se evaluó la presión de sello, visión fibroscópica a través del dispositivo y se reportaron las complicaciones asociadas al procedimiento. Resultados y conclusiones: El porcentaje global de intuba ción a ciegas a través de la máscara Air-Q en este estudio fue del 55,5%, encontrándolo como un porcentaje no aceptable para recomendar la intubación a ciegas a través de este dispositivo; por otra parte la visión fibroscópica ideal fue aceptable, pudiéndose aconsejar como método para guiar la intubación fibroscópica a través de dispositivo supraglótico.


Assuntos
Humanos
3.
Rev. Fac. Nac. Salud Pública ; 36(2): 28-36, mayo-ago. 2018. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-977010

RESUMO

Resumen Objetivo: Describir la mortalidad y las principales complicaciones secundarias en los pacientes con trauma ortopédico de alta energía, admitidos en el servicio de urgencias del Hospital Universitario San Vicente Fundación. Metodología: Se llevó a cabo un estudio descriptivo retrospectivo de los pacientes, en un período de 18 meses, que cumplieron los criterios de inclusión luego de realizar la búsqueda en la base de datos del Hospital. Se revisaron 10 259 historias clínicas, de las cuales 161 cumplían los criterios de inclusión. Las variables cuantitativas se analizaron mediante medias y desviaciones estándar, y las cualitativas, a través de frecuencias y proporciones. El análisis estadístico se efectuó con el SPSS® 21. Resultados: La mayoría de pacientes afectados correspondía al sexo masculino (80,7 %), con edad promedio de 37,5 años; el principal hueso afectado fue la tibia (68,3 %). El principal mecanismo de trauma fue accidente de tránsito (82 %), siendo la motocicleta el vehículo involucrado con mayor frecuencia (65,8 %). La mortalidad fue baja, fallecieron tres pacientes. Las principales complicaciones fueron osteomielitis crónica y tromboembolismo pulmonar (7,4 y 6,8 %, respectivamente). Dieciséis pacientes requirieron ingreso a la unidad de cuidados intensivos (9,9 %), con un promedio de estancia de 6,9 días. Conclusiones: El trauma ortopédico de alta energía no es un factor de mortalidad independiente; sin embargo, impacta sobre la salud pública, debido a la discapacidad que esta lesión genera en individuos laboralmente activos, lo que lleva a ausentismo laboral y pérdida de la productividad.


Abstract Objective: to describe the mortality and the main secondary complications in patients with high-energy orthopedic trauma treated at the emergency service of the Hospital Universitario San Vicente Fundación. Methodology: descriptive retrospective study carried out in an 18-month period with patients following the inclusion criteria and after a search conducted in the hospital's database. 10,259 patient medical records were reviewed, out of which 161 followed the inclusion criteria. The quantitative variables were analyzed by standard means and deviations. The qualitative variables were analyzed by frequency and proportions. Results: most of the affected patients were males (80.7%), with a mean age of 37.5 years, the most affected bone was the tibia (68.3). Transit accident was the main mechanism of trauma (82%), and the most frequently involved vehicle was the motorcycle (65.8%). There was a low mortality of three patients. The main complications were chronic osteomyelitis and pulmonary thromboembolism (7.4% and 6.8%, respectively). Sixteen patients needed attention in the Intensive Care Unit (9.9%), remaining there for an average of 6.9 days. Conclusions: high-energy orthopedic trauma is not an independent mortality factor. However, it affects public health by generating medical leaves of active workers, which causes work absences and diminishes productivity.


Resumo Objetivo: Descrever a mortalidade e as principais complicações secundárias nos pacientes com trauma ortopédico de alta energia, tratados no serviço de urgências do Hospital Universitario San Vicente Fundación. Metodologia: foi feito um estudo descritivo retrospectivo dos pacientes, em 18 meses, respeitando critérios de inclusão após realizar a pesquisa na base de dados do Hospital. Revisaram-se 10 259 histórias clínicas, das quais 161 acatavam os critérios de inclusão. As variáveis quantitativas analisaram-se por meio de medições e desvios standards. As variáveis qualitativas analisaram-se através de frequências e proporções. Resultados: a maioria dos pacientes afetados eram de sexo masculino (80,7 %), com idade média de 37,5 anos, o principal osso afetado foi a tíbia (68,3 %). O principal mecanismo de trauma foi acidente de trânsito (82%), sendo a motocicleta o veículo envolvido com mais frequência (65,8 %). A mortalidade foi baixa, morreram três pacientes. As principais complicações foram a ostomielite crônica e o tromboembolismo pulmonar (7,4 e 6,8 %, respetivamente). Dezesseis pacientes precisaram atenção na Unidade de Terapia Intensiva (9,9%), com média de tempo na uti de 6,9 dias. Conclusões: o trauma ortopédico de alta energia não é um fator de mortalidade independente. Porém, afeta a saúde pública pelo impedimento gerado em pessoas que trabalham, porque elas devem se ausentar dos seus labores e a produtividade diminui.

4.
Rev. colomb. anestesiol ; 46(1): 37-41, Jan.-Mar. 2018. tab
Artigo em Inglês | LILACS, COLNAL | ID: biblio-959774

RESUMO

Abstract Introduction: Currently, there are no devices showing an acceptable success rate in blind intubation in pediatrics. Objectives: The purpose of this particular series of cases is to identify the percentage of successful blind intubations using the Igel laryngeal mask in children between 2 and 35 kg of body weight, in addition to evaluating seal pressure, fiber optics vision through the device, and reporting the occurrence of complications. Materials and methods: A prospective case series in pediatrics; patients from 2 to 35 kg. Results: According to our study, the overall percentage of blind intubation was 23%, while the percentages of ideal and low vision to facilitate the insertion of the bronchoscope into the airway, and then inserting a tracheal tube through the fiber optics was 70%. Conclusion: We feel that the supraglottic I-gel is not the appropriate device for blind intubation; however, it is an acceptable recommendation to conduct fiber optics intubation.


Resumen Introducción: No hay un dispositivo en la actualidad que demuestre apropiado porcentaje de éxito de intubación a ciegas en pediatría. Objetivos: El propósito de esta serie de casos es conocer el porcentaje de éxito de intubación a ciegas a través de la máscara laríngea I-gel en niños pesando entre 2 y 35 kilos, además evaluar la presión de sello, la visión fibroscópica a través del dispositivo y reportar la aparición de complicaciones. Materiales y Métodos: Serie prospectiva de casos en pediatría, en pacientes de 2 a 35 kilos. Resultados: En nuestro estudio el porcentaje global de intubación a ciegas fue del 23%, el porcentaje de visión ideal y visión baja, que permiten fácil introducción del broncoscopio en la via aérea y luego a través del fibroscopio introducir un tubo traqueal, fue de un 70%. Conclusiones: Consideramos que el I-gel supraglótico no es un dispositivo adecuado para intubación a ciegas. Sin embargo, tiene un valor aceptable para recomendar realizar intubación fibro-óptica a través del dispositivo supraglótico I-gel. Results: According to our study, the overall percentage of blind intubation was 23%, while the percentages of ideal and low vision to facilitate the insertion of the bronchoscope into the airway, and then inserting a tracheal tube through the fiber optics was 70%. Conclusions: We feel that the supraglottic I-gel is not the appropriate device for blind intubation; however, it is an acceptable recommendation to conduct fiber optics intubation.


Assuntos
Humanos
5.
Rev. colomb. anestesiol ; 46(4): 292-299, 2018. tab, graf
Artigo em Inglês | LILACS, COLNAL | ID: biblio-978210

RESUMO

Abstract Introduction: Airway-related problems are the most common perioperative complications in pediatric anesthesia and, among them, the most significant is laryngospasm. The type of device used to secure the airway has been found to be among the factors responsible for this outcome. Objective: To determine whether the use of the classic laryngeal mask (LM) creates a non-inferior risk of laryngospasm compared with the use of the endotracheal tube (ET) in children. Method: Non-inferiority, controlled, double-blind clinical trial with random assignment that included 260 children ages 2 to 14 years, American Society of Anaesthesiology I to III, taken to surgical procedures under general anesthesia. The primary outcome was the development of laryngospasm, and the need to exchange devices, airway trauma, and other respiratory complications were assessed as secondary outcomes. A 10% non-inferiority margin was selected for the difference between the 2 devices. Results: A total of 270 patients were recruited, and 135 were assigned to each group. Laryngospasm occurred in 3.3% of the patients, with an incidence of 5.2% in the LM group versus 1.5% for the ET group, for a difference of 3.7% and a 95% confidence interval (-0.7%, 7.9%). No differences were found among bradycardia, cardiac arrest, and death outcomes. Conclusion: The use of LM in children 2 to 14 years of age taken to various surgical procedures is not inferior or superior to ET in terms of the development of laryngospasm. Trial Resgistration: Clincaltrials.gov, NCT01288248.


Resumen Introducción: Los problemas relacionados con el manejo de la vía aérea son las complicaciones perioperatorias más comunes en la anestesia pediátrica; de ellos, el laringoespasmo es el principal. Dentro de los factores de riesgo se ha encontrado que el tipo de dispositivo empleado para el aseguramiento de la vía aérea puede ser responsable de este desenlace. Objetivo: Determinar si el uso de Máscara Laríngea Clásica (ML) genera un riesgo no inferior al uso de Tubo Endotraqueal (TET) para desarrollar laringoespasmo en niños. Metodología: Ensayo clínico controlado de no inferioridad, ciego único, con asignación aleatoria, que incluyó 260 niños de 2 a 14 años, ASA I-III, sometidos a procedimientos quirúrgicos bajo anestesia general. El desenlace primario fue el desarrollo de laringoespasmo y como desenlaces secundarios se evaluaron la necesidad de cambio de dispositivo, trauma de vía aérea y otras complicaciones respiratorias. Se estableció un margen de no inferioridad del 10% para la diferencia entre ambos dispositivos. Resultados: Se reclutaron 270 pacientes, 135 en cada grupo. El laringoespasmo se presentó en el 3,3% de los pacientes, con una incidencia en el grupo de ML de 5,2% vs 1,5% para TET, con una diferencia de 3,7% un IC del 95%: (-0,7%, 7,9%). No se encontraron diferencias entre los desenlaces de bradicardia, paro cardiaco y muerte. Conclusión: El uso de ML en niños de 2-14 años de edad sometidos a diversos procedimientos quirurgicos no es inferior ni superior al TET para desarrollo de laringoespasmo.


Assuntos
Humanos , Masculino , Feminino , Criança , Laringismo , Máscaras Laríngeas , Equipamentos e Provisões , Anestesia Geral , Procedimentos Cirúrgicos Operatórios , Bradicardia , Risco , Fatores de Risco , Manuseio das Vias Aéreas , Parada Cardíaca , Anestesia
6.
Rev. colomb. anestesiol ; 45(2): 100-107, Apt.-June 2017. ilus, tab
Artigo em Inglês | LILACS, COLNAL | ID: biblio-900343

RESUMO

Introduction: Intravenous rescue analgesia in the postoperative anesthesia care unit (PACU) is the most effective method for reducing postoperative pain (POP) when perioperative multimodal analgesia fails to control it. Appropriate analgesia during these first postoperative hours may prevent morbidity associated with pain. Objective: To compare the effectiveness of intravenous morphine versus fentanyl in the PACU for reducing severe POP. Methods: Randomized, prospective, double blind trial that included patients with severe POP using VAS in the PACU. Rescue was performed on one group with 01 mg/kg morphine and with another with 1 mcg/kg of fentanyl every 5 min intravenously until pain was reduced from severe to mild (VAS<4). 30 patients were included in both groups. Results: There were no significant differences in the percentage of patients with reduction of severe POP to mild 5 min after the injection of morphine or fentanyl, or in the subsequent rescue analgesia intervals (p > 0.05). Similarly, there were no significant differences in mean VAS (95% CI) in morphine or fentanyl groups beginning 5 min after the first analgesic dose (p > 0.05) between the groups. There were no significant differences in side effects such as respiratory depression, nausea, vomiting or pruritus (p = 1.0). There was a high satisfaction in both groups (p > 0.05). Conclusions: Morphine and fentanyl were equally effective in treating severe POP after 5 min and following intervals after rescue analgesia was initiated, during 25 min at PACU, with no differences in efficacy or adverse effects between groups Register # NCT02145975 clinical-trials.gov, prospective.


Introducción: La analgesia intravenosa de rescate en la unidad de cuidados postanestesicos (UCPA), es la forma más efectiva de reducir el dolor POP, cuando la analgesia mutimodal perioperatoria falla en controlarlo. Una adecuada analgesia en las primeras horas previene la morbilidad asociada al dolor. Objetivo: Compararla efectividad para reducir el dolor POP severo de fentanilo versus morfina en recuperación postanestésica. Metodología: Estudio aleatorizado, prospectivo, doble ciego, en pacientes con dolor severo POP medido con la escala EVA. El rescate se hizo con un grupo morfina a 0,1 mg/kg versus fentanilo a 1 mcg/kg, cada 5 minutos, vía intravenosa, hasta reducir el dolor de severo a leve (EVA <4). Se incluyeron 30 pacientes en el grupo morfina y 30 en el grupo fentanilo. Resultados: No se observaron diferencias en porcentaje de pacientes con reducción del dolor severo a leve desde los 5 minutos luego del rescate entre morfina o fentanilo, ó en los intervalos restantes (p>0,05). Similarmente, no se encontraron diferencias significativas en la media de EVA (IC 95%) desde los 5 minutos luego del rescate (p > 0.05) entre los grupos. No hubo diferencias en efectos adversos como depresión respiratoria, náuseas, vómitos o prurito entre grupos (p = 1,0). La satisfacción fue comparable en ambos grupos (p >0,05). Conclusiones: La morfina y el fentanilo fueron igualmente efectivos para el rescate en dolor severo desde los primeros 5 minutos, sin diferencias en los efectos adversos en ambos grupos. Registro # NCT02145975 (clinicaltrials.gov, prospectivo).


Assuntos
Humanos
7.
Rev. colomb. anestesiol ; 33(2): 129-133, abr.-jun. 2005. ilus
Artigo em Espanhol | LILACS | ID: lil-423787

RESUMO

Uno de los problemas más graves que enfrenta el anestesiólogo está relacionado con la imposibilidad de ventilar y oxigenar un paciente. Esta situación es la causa primaria de paro cardíaco durante la anestesia general.1 Las guías para el manejo de la vía aérea difícil de la American Society of Anesthesiologist sugieren como procedimiento de urgencia para estos casos la cricotiroidotomía, así como la preparación de los anestesiólogos y el personal médico de urgencias y de cuidado intensivo en las técnicas traslaríngeas. Se analizará el caso de un niño de seis meses de edad con imposibilidad para ventilar y oxigenar, y en el que la técnica de cricotiroidotomía con aguja permitió la oxigenación transitoria mientras se hacía un acceso quirúrgico inmediato...


Assuntos
Ablação por Cateter , Dilatação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA