Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Fisioter. Mov. (Online) ; 35: e35141, 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1404790

RESUMO

Abstract Introduction The International Physical Activity Ques-tionnaire (IPAQ) and Baecke inventory are commonly used in cardiovascular rehabilitation routines. Thus, it is understood that investigations on the equivalence of outcomes between these two tools may be relevant to measure the magnitude of possible reproducibility and correlations between them. Objective To compare in cardiac patients the level of physical activity obtained through the IPAQ and Baecke inventory and correlate outcomes obtained with a 6-minute walk test. Methods In total, 65 heart disease patients included in a cardiovascular rehabilitation program (40 male and 25 female) were included, with a mean age of 65.8 ± 10.5 years. The data were obtained from the application of a standardized form, containing the proposed study objects, which were the IPAQ and Baecke inventory. In addition, data regarding anthropometric measurements (body mass, height, and body mass index - BMI), waist-to-hip ratio, blood pressure, and performance in the 6-minute walk test were measured. Results The main outcomes refer to the weak association between the instruments evaluated, which showed a strong relationship only between free time physical activity (r = 1), while in the other categories and when compared to the 6-minute walk test, the verified agreement was not significant. Conclusion The questionnaires are strongly equivalent only for free time physical activity, in the other categories and when compared to the 6-minute walk test, the agreement was not significant. Thus, based on the results, implementation in clinical practice considering the use of these tools with equivalence is not recommended.


Resumo Introdução O Questionário Internacional de Atividade Física (IPAQ) e o inventário de Baecke são comumente utilizados em rotinas de reabilitação cardiovascular. Assim, entende-se que investigações sobre a equiva-lência de desfechos entre essas duas ferramentas possam ser relevantes para mensurar a magnitude da possível reprodutibilidade e correlação entre tais métodos. Objetivo Comparar em cardiopatas o nível de atividade física obtido por meio do IPAQ e do Baecke e correlacionar desfechos obtidos com o teste de cami-nhada de 6 minutos (TC6). Métodos Foram incluídos no estudo 65 cardiopatias inseridos em um programa de reabilitação cardiovascular, sendo 40 do sexo masculino e 25 do sexo feminino, com idade média correspondente a 65,8 ± 10,5 anos. Os dados foram obtidos a partir de um formulário padronizado, contendo os objetos de estudo propostos (IPAQ e Baecke). Além disso, dados referentes a medidas antropométricas (massa corporal, estatura e índice de massa corpórea), relação de cintura quadril, pressão arterial e TC6 foram avaliados. Resultados Os principais desfechos se referem à fraca associação entre os instrumentos avaliados, que demonstraram relação forte somente entre atividade física de tempo livre (r = 1), sendo que nas demais categorias e quando comparadas ao TC6 a concordância verificada não apresentou significância estatística. Conclusão Os questionários se equivalem fortemente somente quando diz respeito à atividade física de tempo livre. Desta forma, não faz sentido a implementação de prática clínica que considere a utilização das ferramentas IPAQ e Baecke com equivalência, o que verificou-se não existir.

2.
Fisioter. Mov. (Online) ; 33: e003322, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1101191

RESUMO

Abstract Introduction: Given the practicality and low cost of elastic devices, a comparison with conventional devices may be able to quantify gains from both tools for further conclusions. Objective: Compare the effect of resistance training with elastic (tubes and resistance band) and conventional (weight machines and dumbbells) devices on body composition. Method: This is a systematic review and meta-analysis. The PubMed/MEDLINE, Embase, PEDro and CENTRAL databases were searched from the earliest records to July 25, 2018. Data were described in standardized mean difference (SMD) with a 95% confidence interval (95% CI). Results: Four studies were included. The results of the meta-analysis did not show superiority among the analyzed methods for the variables investigated (SMD = -2.04, 95% CI -7.56, 3.48, p < 0.00001, lean mass: SMD = 0.28, 95% CI -0.29, 0.85, p = 0.97, body fat: SMD = 2.77, 95% CI -0.05, 5.59, p = 0.92, body mass: SMD = 1.22, 95% CI -0.29, 2.74, p = 0.11). Conclusion: The results of the meta-analysis showed superiority of outcome from training in conventional devices only for the variable fat mass. For the other variables, no statistically significant differences were found. Elastic resistance can promote similar outcomes to resistance in different population profiles and from various protocols on variables related to body composition.


Resumo Introdução: Tendo em vista a praticidade e o baixo custo dos dispositivos elásticos, uma comparação com dispositivos convencionais (halteres e máquinas de peso) pode ser capaz de quantificar os resultados observados para posteriores conclusões sobre eventual tendência de superioridade verificada entre os métodos investigados. Objetivo: Comparar o efeito do treinamento resistido em dispositivos elásticos (tubos e faixa elástica) e convencionais (máquinas de peso e halteres) sobre a composição corporal. Método: Trata-se de uma revisão sistemática e meta-análise. Foram pesquisadas as bases de dados PubMed/MEDLINE, Embase, PEDro e CENTRAL desde os registros mais antigos até 25 de julho de 2018. Os dados foram descritos em standardized mean difference (SMD) com intervalo de confiança de 95% (95% CI). Resultados: Quatro estudos foram incluídos. Os resultados da meta-análise não demonstraram superioridade entre os métodos analisados para as variáveis investigadas (massa gorda: SMD= -2.04; 95% CI 7.56, 3.48; p < 0.00001; massa magra: SMD = 0.28; 95% CI -0.29, 0.85; p = 0.97; gordura corporal: SMD = 2.77; 95% CI -0.05, 5.59; p = 0.92; massa corporal: SMD = 1.22; 95% CI -0.29, 2.74; p = 0.11). Conclusão: Houve superioridade de resultado apenas para a variável massa gorda, que demonstrou melhores resultados oriundos do treinamento em dispositivos convencionais. Para as demais variáveis, não foram identificadas diferenças estatisticamente significantes. A resistência elástica é capaz de promover desfechos similares a resistência convencional, em diferentes perfis de população e a partir de protocolos diversos sobre variáveis relacionadas a composição corporal.


Resumen Introducción: Debido a la practicidad y el bajo costo de los dispositivos elásticos, una comparación con los dispositivos convencionales (pesas y mancuernas) puede cuantificar los beneficios de ambas herramientas para obtener conclusiones adicionales. Objetivo: Comparar el efecto del entrenamiento de resistencia en dispositivos elásticos (tubos y banda elástica) y convencionales (pesas y mancuernas) en la composición corporal. Método: Esta es una revisión sistemática y metaanálisis. En las bases de datos PubMed/MEDLINE, Embase, PEDro y CENTRAL se buscaron desde los registros más antiguos hasta el 25 de julio de 2018. Los datos se describieron en la diferencia de medias estandarizada (DME) con un intervalo de confianza del 95% (IC del 95%). Resultados: Se incluyeron cuatro estudios. Los resultados del metaanálisis no mostraron una superioridad entre los métodos analizados para las variables investigadas (masa grasa, SMD=-2.04, IC 95% -7.56, 3.48, p < 0,00001, masa magra: SMD = 0.28, IC 95% -0.29, 0.85 , p = 0,97, grasa corporal: SMD = 2,77, IC 95% -0,05, 5,59, p = 0,92, masa corporal: SMD = 1,22, IC 95% -0,29, 2,74, p = 0,11). Conclusión: Hubo una superioridad de los resultados del entrenamiento en dispositivos convencionales solo para la variable masa grasa. Para las otras variables, no se encontraron diferencias estadísticamente significativas. La resistencia elástica es capaz de promover resultados similares a la resistencia convencional en diferentes perfiles de población y de varios protocolos sobre variables relacionadas con la composición corporal.


Assuntos
Resistência Física , Peso Corporal , Exercício Físico , Especialidade de Fisioterapia
3.
Rev. bras. med. trab ; 17(4): 530-536, 20-12-2019.
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1104021

RESUMO

Introdução: A saúde do trabalhador ganha destaque em âmbito científico, sendo tema de pesquisas e debates internacionais, apresentando o estresse laboral como potencial agente estressor. Objetivo: Caracterizar a incidência de sintomatologia referente à ansiedade e à depressão correlacionada aos níveis socioeconômicos em servidores técnico-administrativos de uma universidade estadual do estado de São Paulo. Métodos: A amostra foi composta de 89 participantes. Os dados foram obtidos por meio do inventário de sintomas de estresse para adultos de Lipp, para detectar o nível de estresse; da escala hospitalar de ansiedade e depressão, para análise de ansiedade e depressão; e de um questionário informativo para detectar o nível educacional e sociodemográfico. Resultados: Verificou-se que 47% dos participantes apresentaram sintomas de ansiedade e 39% de depressão, não havendo relação direta com o nível socioeconômico. Além disso, observou-se que, entre os indivíduos que apresentavam ansiedade, 50% eram docentes, e, do total de indivíduos com depressão, 38,4% eram do setor administrativo. O estresse encontra-se em maior escala nas categorias ensino superior (29,6%) e pós-graduados (33,3%). Conclusões: Os achados demonstraram elevada prevalência de ansiedade e depressão em todas as classes socioeconômicas investigadas. Ademais, indivíduos de nível educacional elevado são mais estressados que os de nível educacional inferior.


Background: Occupational health is increasing in visibility within the scientific community and has become a field of international research and discussions in which occupational stress is described as a possible stressor. Objective: To analyze the relationship between anxiety and depression symptoms and socioeconomic level among technical-administrative employees of a public university in the state of São Paulo, Brazil. Methods: The sample comprised 89 participants. Data were obtained through Lipp's Inventory of Stress Symptoms for adults to identify levels of stress and the Hospital Anxiety and Depression scale. An additional questionnaire was administered to gather information on educational and socioeconomic levels. Results: About 45% of the participants exhibited symptoms of anxiety and 39% of depression, however, without direct relationship with their socioeconomic level. Among the participants with depression 50% were professors, and among those with depression 38.4% were administrative employees. Stress was more frequent among the participants who had attended higher education (29.6%) and graduate studies (33.3%). Conclusion: The study results indicate a high prevalence of anxiety and depression regardless of the socioeconomic level of the participants. Stress was more frequent among the participants with higher educational level.

4.
Arq. bras. cardiol ; 111(1): 94-101, July 2018. tab
Artigo em Inglês | LILACS | ID: biblio-950196

RESUMO

Abstract Background: Type 1 diabetes mellitus can cause autonomic changes, which can be assessed by heart rate variability. Among the heart rate variability assessment methods, the symbolic analysis and Shannon entropy, based on the Chaotic dynamics, have gained prominence. Objective: To compare heart rate variability indexes, obtained through symbolic analysis and Shannon entropy, in young adults with type 1 diabetes mellitus and healthy young individuals, associated with the analysis of linear indexes; and to verify if there are associations between the indexes obtained by the symbolic analysis and by Shannon entropy and linear indexes in diabetic individuals. Methods: Heart rate variability data from 39 young adults with type 1 diabetes mellitus and 43 healthy young individuals were analyzed, using a cardio-frequency meter. Linear indexes (standard deviation of all normal RR intervals recorded in a time interval expressed in milliseconds; square root of the mean of the squared differences between adjacent normal RR intervals in a time interval expressed in milliseconds; low and high frequency components in millisecond squared; and normalized units and ratio between low and high frequency components) and nonlinear ones (Shannon entropy and symbolic analysis - standard without variation; with one or two variations; and with two different variations) of the heart rate variability were calculated. The statistical significance was set at 5%, and the confidence interval was 95%. Results: Significantly lower values were observed in the DM1 group compared to healthy young adults for the standard deviation indexes of all normal RR intervals recorded in a time interval [37.30 (29.90) vs. 64.50 (36.20); p = 0.0001], square root of the mean of the squared differences between adjacent normal RR intervals in a time interval [32.73 (17.43) vs. 55.59 (21.60); p = 0.0001], low frequency component [402.00 (531.00) vs. 1,203.00 (1,148.00); p = 0.0001], high frequency component [386.00 (583.00) vs. 963.00 (866.00); p = 0.0001] and the pattern with two different variations [15,33 (9,22) vs. 20.24 (12.73); p = 0.0114], with the effect of this difference being considered large (standard deviation of all normal RR intervals recorded in a time interval, square root of the mean of the squared differences between adjacent normal RR intervals in a time interval and low frequency component), medium (high frequency component) and small (standard with two different variations). The agreement of the associations between the linear and non-linear indexes was considered elevated for the high frequency component index - normalized units (r = -0.776), with the standard index without variation, and moderate for the indexes square root of the mean of the squared differences between adjacent normal RR intervals in a time interval (r = 0.550), standard deviation of all normal RR intervals recorded in a time interval (r = 0.522), high frequency component - normalized units (r = 0.638) with the index standard with two similar variations, as well as for the indexes square root of the mean of the squared differences between adjacent normal RR intervals in a time interval (r = 0.627) and high frequency component - normalized units (r = 0.601) with the index standard with two different variations. Conclusion: Type 1 diabetes mellitus influenced linear indexes and symbolic analysis, but not yet in the complexity of heart rate variability. Additionally, heart rate variability indexes correlated with the symbolic dynamics.


Resumo Fundamento: O diabetes melito tipo 1 pode promover alterações autonômicas, que podem ser avaliadas pela variabilidade da frequência cardíaca. Dentre os métodos da variabilidade da frequência cardíaca, têm ganhado destaque a análise simbólica e a entropia de Shannon, baseadas na dinâmica do caos. Objetivo: Comparar índices da variabilidade da frequência cardíaca obtidos por meio da análise simbólica e da entropia de Shannon, entre jovens com diabetes melito tipo 1 e jovens saudáveis, associados à análise de índices lineares; e verificar se há associações entre os índices obtidos pela análise simbólica e pela entropia de Shannon e índices lineares em indivíduos diabéticos. Métodos: Foram analisados dados da variabilidade da frequência cardíaca de 39 jovens com diabetes melito tipo 1 e 43 jovens saudáveis, obtidos por meio de um cardiofrequencímetro. Foram calculados os índices lineares (desvio padrão de todos os intervalos RR normais gravados em um intervalo de tempo expresso em milissegundo; raiz quadrada da média do quadrado das diferenças entre intervalos RR normais adjacentes em um intervalo de tempo expresso em milissegundo; componentes de baixa e alta frequência, em milissegundo ao quadrado; e unidades normalizadas e razão entre componente de baixa e alta frequência) e não lineares (entropia de Shannon e análise simbólica - padrão sem variação; com uma ou duas variações; e com duas variações diferentes) da variabilidade da frequência cardíaca. A significância estatística adotada foi fixada em 5%, e o intervalo de confiança em 95%. Resultados: Foram observados valores significativamente menores no Grupo DM1 em comparação aos jovens saudáveis para os índices desvio padrão de todos os intervalos RR normais gravados em um intervalo de tempo [37,30 (29,90) vs. 64,50 (36,20); p = 0,0001], raiz quadrada da média do quadrado das diferenças entre intervalos RR normais adjacentes em um intervalo de tempo [32,73 (17,43) vs. 55,59 (21,60); p = 0,0001], componente de baixa frequência [402,00 (531,00) vs. 1.203,00 (1.148,00); p = 0,0001], componente de alta frequência [386,00 (583,00) vs. 963,00 (866,00); p = 0,0001] e padrão com duas variações diferentes [15,33 (9,22) vs. 20,24 (12,73); p = 0,0114], sendo o efeito desta diferença considerado grande (desvio padrão de todos os intervalos RR normais gravados em um intervalo de tempo, raiz quadrada da média do quadrado das diferenças entre intervalos RR normais adjacentes em um intervalo de tempo e componente de baixa frequência), médio (componente de alta frequência) e pequeno (padrão com duas variações diferentes). A concordância das associações entre os índices lineares e não lineares foi considerada elevada para o índice componente de alta frequência - unidades normalizadas (r = -0,776), com o índice padrão sem variação, e moderada para os índices raiz quadrada da média do quadrado das diferenças entre intervalos RR normais adjacentes em um intervalo de tempo (r = 0,550), desvio padrão de todos os intervalos RR normais gravados em um intervalo de tempo (r = 0,522), componente de alta frequência - unidades normalizadas (r = 0,638) com o índice padrão com duas variações similares, assim como para os índices raiz quadrada da média do quadrado das diferenças entre intervalos RR normais adjacentes em um intervalo de tempo (r = 0,627) e componente de alta frequência - unidades normalizadas (r = 0,601) com o índice padrão com duas variações diferentes. Conclusão: O diabetes melito tipo 1 influenciou nos índices lineares e na análise simbólica, mas ainda não na complexidade da variabilidade da frequência cardíaca. Além disso, índices de variabilidade da frequência cardíaca apresentaram correlação com a dinâmica simbólica.


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Diabetes Mellitus Tipo 1/fisiopatologia , Frequência Cardíaca/fisiologia , Fatores de Tempo , Estudos de Casos e Controles , Estudos Transversais , Entropia
5.
ABCS health sci ; 41(1): 20-22, jan.-abr. 2016. tab
Artigo em Português | LILACS | ID: lil-782286

RESUMO

INTRODUÇÃO: O diabetes mellitus gestacional (DMG) é uma alteração patológica do metabolismo energético materno desencadeado pela incapacidade da gestante produzir quantidades suficientes de insulina para compensar a intolerância à glicose desencadeada pela ação do hormônio lactogênio placentário (HPL). Tendo em vista que os níveis plasmáticos do HPL são proporcionais à massa da placenta e que eles são máximos próximo ao período em que a placenta adquire seu maior tamanho e período que a hiperglicemia se manifesta na gestante com DMG, é possível inferir que talvez exista correlação entre a massa placentária e essa doença. OBJETIVO: Avaliar se existe correlação entre o DMG e a massa placentária. MÉTODOS: Pesquisa descritiva, transversal e com abordagem quantitativa, que foi realizada em um hospital público de Santa Catarina, Brasil. A pesquisa incluiu 20 mulheres grávidas, 10 com e 10 sem DMG, que concordaram em participar do estudo. RESULTADOS: A média das massas das placentas do Grupo Controle foi de 505,63±12,18 g, enquanto a do grupo com DMG foi de 561,00 ±14,25 g. CONCLUSÃO: Este estudo sugere que a massa placentária das gestantes com DMG é significativamente maior do que a massa das placentas das gestantes hígidas.


INTRODUCTION: Gestational diabetes mellitus (GDM) is a pathological alteration of maternal energy metabolism unleashed by the pregnant woman's inability to produce sufficient amounts of insulin to compensate for glucose intolerance triggered by the action of placental lactogenic hormone (HPL). Given that plasma levels of HPL are proportional to the placenta mass andthat they are close to the maximum period in which the placenta acquires its larger size and that hyperglycemia is manifested in pregnant women with GDM, it is possible to infer that there might be correlation between the placental mass and this disease. OBJECTIVE: To evaluate whether there is correlation between GDM and placental mass. METHODS: Descriptive, cross-sectional and quantitative approach survey, which was conducted in a publichospital in Santa Catarina, Brazil. The survey included 20 pregnantwomen, 10 with and 10 without GDM, who agreed to participate inthe study. RESULTS: The average of placenta masses of the Control Group was 505.63±12.18 g, while of the GDM group it was 561,00 ±14.25 g. CONCLUSION: This study suggests that placental mass of pregnant women with GDM is significantly greater than the mass placenta of healthy pregnant women.


Assuntos
Humanos , Feminino , Gravidez , Gestantes , Diabetes Gestacional , Placenta
6.
Rev. paul. pediatr ; 32(2): 279-285, 06/2014. tab
Artigo em Inglês | LILACS | ID: lil-718523

RESUMO

To gather current information about the effects of type 1 diabetes mellitus on children's cardiac autonomic behavior. DATA SOURCES: The search of articles was conducted on PubMed, Ibecs, Medline, Cochrane, Lilacs, SciELO and PEDro databases using the MeSH terms: "autonomic nervous system", "diabetes mellitus", "child", "type 1 diabetes mellitus", "sympathetic nervous system" and "parasympathetic nervous system", and their respective versions in Portuguese (DeCS). Articles published from January 2003 to February 2013 that enrolled children with 9-12 years old with type 1 diabetes mellitus were included in the review. DATA SYNTHESIS: The electronic search resulted in four articles that approached the heart rate variability in children with type 1 diabetes mellitus, showing that, in general, these children present decreased global heart rate variability and vagal activity. The practice of physical activity promoted benefits for these individuals. CONCLUSIONS: Children with type 1 diabetes mellitus present changes on autonomic modulation, indicating the need for early attention to avoid future complications in this group...


Reunir informaciones actuales sobre los efectos de la diabetes mellitus tipo 1 sobre el comportamiento cardiaco de niños. FUENTES DE DATOS: La búsqueda de artículos se realizó en las bases de datos PubMed, Ibecs, Medline, Cochrane, Lilacs y PEDro por medio de los descriptores del área de salud (DeCS) a continuación: "sistema nervioso autónomo", "diabetes mellitus", "niño", "diabetes mellitus tipo 1", "sistema nervioso simpático" y "sistema nervioso parasimpático" sus respectivas versiones en lengua inglesa (MeSH).Los artículos fueron publicados de enero de 2003 a febrero de 2013, implicando a niños de nueve a 12 años portadores de diabetes mellitus tipo 1. SÍNTESIS DE LOS DATOS: La búsqueda resultó en cuatro artículos que trataban la variabilidad de la frecuencia cardiaca en niños con diabetes mellitus tipo 1, demostrando que, por lo general, esos niños presentan reducción de la variabilidad de la frecuencia cardiaca global y de la actividad vagal. La práctica de actividad física promueve beneficios al organismo de niños con diabetes mellitus tipo 1. CONCLUSIONES: Niños diabéticos tipo 1 presentan modificaciones en la modulación autonómica, lo que demuestra la necesidad de atención temprana a esa población para evitar complicaciones futuras...


Reunir informações atuais acerca dos efeitos do diabetes melito tipo 1 sobre o comportamento autonômico cardíaco de crianças. FONTES DE DADOS: A busca dos artigos foi realizada nas bases de dados PubMed, Ibecs, Medline, Cochrane, Lilacs, SciELO e PEDro por meio dos seguintes descritores da área da saúde (DeCS): "sistema nervoso autônomo", "diabetes mellitus", "criança", "diabetes mellitus tipo 1", "sistema nervoso simpático" e "sistema nervoso parassimpático" e suas respectivas versões em língua inglesa (MeSH). Os artigos foram publicados de janeiro de 2003 a fevereiro de 2013, envolvendo crianças de nove a 12 anos portadoras de diabetes melito tipo 1. SÍNTESE DOS DADOS: A busca resultou em quatro artigos que abordam a variabilidade da frequência cardíaca em crianças com diabetes melito tipo 1, demonstrando que, em geral, essas crianças apresentam redução da variabilidade da frequência cardíaca global e da atividade vagal. A prática de atividade física promove benefícios no organismo de crianças com diabetes melito tipo 1. CONCLUSÕES: Crianças diabéticas tipo 1 apresentam modificações na modulação autonômica, o que demonstra a necessidade de atenção precoce a essa população para evitar complicações futuras...


Assuntos
Humanos , Criança , Diabetes Mellitus Tipo 1/complicações , Doenças do Sistema Nervoso Autônomo/complicações , Frequência Cardíaca
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA