RESUMO
Objective:To discuss the quality control method of injection pump and analyze the factors that affect the quality control of injection pump.Methods: Flow error and blocking alarm error were tested by the INFUTEST 2000E dual-channel infusion pump analyzer according to the national calibration specifications.Results: The syringe specifications, injection speed and injection solvent could influence the test for accuracy of injection pump. The lower injection speed set, the bigger flow test error was, while the smaller the blocking alarm test error was. On the other hand, the higher the injection speed set, the smaller the flow test error was and the bigger the blocking alarm test error was. Besides, the higher qualified rate of flow test was, the lower the qualified rate of blocking alarm test was.Conclusion: The quality control of injection pump should abide by the principle of controllable risk, and should not pursuit too much accuracy.
RESUMO
10.3969/j.issn.2095-4344.2013.26.006
RESUMO
<p><b>OBJECTIVE</b>To provide the appropriate dust control measures for jade carving operations.</p><p><b>METHODS</b>Dust concentrations in the workplace were measured according to GB/T 5748-85. Ventilation system of dust control were measured according to GB/T 16157-1996. Dust particle size distributions for different sources and particle size fraction collecting efficiencies of the dust collectors were measured with WY-1 in-stack 7 stage cascade impactors.</p><p><b>RESULTS</b>On the basis of adopting wet process in the carving operations, local exhaust ventilation system for dust control was installed, which included: the special designed slot exhaust hoods with hood face velocity of 2.5 m/s and exhaust volume of 600 m3/h. The pipe sizes were determined according to the air volume passing through the pipe and the reasonable air velocities. Impinging scrubber or bag filter dust collector were selected to treat the dust laden air from the local exhaust ventilation system, which gave a total collecting efficiency of 97% for impinging scrubber and 98% for bag filter; The type of fan and its size were selected according to the total air volume of the ventilation system and maximum total pressure needed for the longest pipe line plus the pressure drop of the dust collector.</p><p><b>CONCLUSIONS</b>Practical application showed that, after installation and use of the appropriate dust control measures, the dust concentrations in the workplaces could meet or nearly meet the national hygienic standard and the dust laden air at the local exhaust ventilation system could meet the national emission standard.</p>
Assuntos
Humanos , Poeira , Exposição Ocupacional , Tamanho da PartículaRESUMO
Objective To utilize the expert resource in central hospital for helping doctors in community hospital to make suitable diagnosis and treatment,improve the technical level of community medical care. Methods The Telemedicine Diagnosis System is developed based on B/S mode and Microsoft Visual Studio.net C#2005 in Windows platform. Results The Telemedicine Diagnosis System has been developed, and realized the function of interface display, information management, medical image transmission and telemedicine diagnosis. Conclusion The system has friendly interface, simple operation, more reliability and quick data transmission, and it can accurately realize the experts' telemedicine diagnosis in time.