Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Internal Medicine ; (12): 225-229, 2011.
Artigo em Chinês | WPRIM | ID: wpr-384291

RESUMO

Objective To evaluate the clinical efficacy and safety of antofloxacin hydrochloride tablet for the treatment of acute bacterial infections. Methods A multi-center randomized control, double blind and double dummy clinical trial was conducted; levofloxacin tablet was chosed as controlled drug. The duration of treatment was 7-14 days in both groups. Results A total of 719 patients were enrolled in the study, in which 359 patients treated with antofloxacin and 360 patients treated with levofloxacin were included. Three hundred and thirty and 337 patients completed the study and met with all the criteria for perprotocol analysis, respectively. By the end of chemotherapy, the cured rates in per protocol set (PPS)population were 79.7% and 77.4%, the effective rates were 95.2% and 96. 7%, and the bacterial clearance were 96. 7% and 97. 5% for the treating and control group, respectively. The clinical and bacterial efficacy of antofloxacin and levofloxacin was comparable by the analysis of infectious sites. Three hundred and fifty-seven and 356 patients in antofloxacin and levofloxacin groups were evaluated the safety.The drug adverse events occurred both in 10. 1%, and drug adverse reactions accurred in 7. 8% and 7.9%patients in the two groups. The most common drug adverse reactions were mild gastroenteric symptoms. No QTc prologation was detected in all the patients. One patient in each group had mild blood glucose increase at the end of therapy, but the glucose returned to normal level without any intervention. No statistic significant difference between the two groups in clinical efficacy and safety was detected (P>0.05).Conclusions Antofloxacin hydrochloride tablet was effective and safe for the treatment of acute bacterial infections.

2.
Acta Pharmaceutica Sinica ; (12): 1149-54, 2010.
Artigo em Inglês | WPRIM | ID: wpr-382522

RESUMO

A high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for the determination of mizoribine in human serum using thiamphenicol as internal standard (IS). The serum samples of mizoribine were precipitated with acetonitrile and separated by HPLC on a reversed phase C18 column with a mobile phase of 0.1% ammonium acetate water solution-methanol (47:53, v/v). Mizoribine and IS were detected in the multiple reaction monitoring mode with precursor/product ion transitions of m/z 258.2/126.0 and 354.1/185.2, respectively. The calibration curves were linear over the range of 0.02-2 microg mL(-1) for mizoribine. The limit of quantification (LOQ) was 0.02 microg mL(-1) with acceptable precision and accuracy. The validated method was successfully applied for the evaluation of a bioequivalence study on Chinese healthy volunteers. The main pharmacokinetics parameters after oral administration of 100 mg mizoribine test or reference formulation were as follows: Cmax (1.00 +/- 0.21), (1.00 +/- 0.22) microg mL(-1); AUC(0-infinity) (6.72 +/- 1.39), (6.48 +/- 1.44) microg h mL(-1); t1/2 (2.77 +/- 0.26), (2.66 +/- 0.29) h; tmax (2.95 +/- 0.78), (2.84 +/- 0.50) h.

3.
Journal of Pharmaceutical Analysis ; (6): 83-90, 2010.
Artigo em Chinês | WPRIM | ID: wpr-621624

RESUMO

Objective To establish a rapid, sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of acyclovir (the metabolite of valacyclovir hydrochloride) in human plasma. Methods After addition of ganciclovir as internal standard (IS), plasma samples were prepared by one-step protein precipitation using acetonitrile as precipitant, followed by an isocratic elution with 0.1% formic acid 3.5μm) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 226.2→152.1 for acyclovir and m/z 256.2→152.1 for the IS. Results The analytical results demonstrated a good linearity over the ranges from 0.005 to 4μg/mL (r=0.9999) for valacyclovir hydrochloride. The relative standard deviations (RSD) of intra-batch and inter-batch were less than 4.06% and 9.23%, respectively. The limit of detection and lower limit of quantification in human plasma were 2ng/mL and 5ng/mL, respectively. Conclusion The method was simple, sensitive, accurate and reproducible and has been successfully applied to a bioequivalence study of valacyclovir hydrochloride capsules in Chinese healthy male volunteers.

4.
Chinese Journal of Clinical Pharmacology and Therapeutics ; (12)2000.
Artigo em Chinês | WPRIM | ID: wpr-677374

RESUMO

Aim To study pharmacokinetics and bioavailablity of domestic penicillin V dispersion tablet in healthy volunteers. Methods According to the crossover design, each volunteer in two groups was orally given a single dose ( 0.75 g ) of domestic penicillin V dispersion tablet or imported penicillinV tablet alternately and the plasma concentrations were determined by RP HPLC. The pharmacokinetic parameters were obtained by using ATPK program and calculated on the basis of open single compartment model. Results After a single oral dose( 0.75 g ), the t 1/2(ke) was ( 0.75 ? 0.10 ) h and ( 0.70 ? 0.14 ) h ,the c max was( 8.44 ? 2.40 ) mg?L -1 and ( 8.75 ? 3.04 ) mg?L -1 at ( 0.56 ? 0.11 ) h and ( 0.63 ? 0.17 ) h and AUC 0~4 was( 8.44 ? 2.40 ) mg?h?L -1 and ( 8.75 ? 3.04 ) mg?h?L -1 for two formulations, respectively. Relative bioavailability of domestic penicillin V dispersion tablet was ( 90.50 ? 8.84 )%. Conclusion The result shows that the two formulations are bioequivalent.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA