China Journal of Orthopaedics and Traumatology ; (12): 309-316, 2022.
Artigo em Chinês | WPRIM | ID: wpr-928314

RESUMO

OBJECTIVE@#To assess the clinical efficacy of minimally invasive technology with trajectory screw fixation for fragility fractures of pelvic(FFP).@*METHODS@#A retrospective case control study was performed to analyze the clinical data of 35 patients with FFP who were treated and followed up between January 2016 and December 2019. There were 12 males and 23 females, aged from 65 to 99 years with an average of(75.4±7.8) years old. There were 13 cases of type Ⅱb, 7 cases of type Ⅱc, 8 cases of type Ⅲa, 2 cases of type Ⅲb, 2 cases of type Ⅲc, 1 case of type Ⅳb, and 2 cases of type Ⅳc according to Rommens FFP comprehensive classification. All patients received the treatment of minimally invasive technology with trajectory screws fixation. According to the different methods of anterior pelvic ring fixation, FFP patients were divided into two groups:12 cases were fixed with the pedicle screw rod system in the anterior pelvic subcutaneous internal fixator (INFIX) group;23 cases were fixed with hollow screws of the pubic symphysis, superior ramus of pubis or acetabular anterior column in the screw group. The operation time, intraoperative blood loss, intraoperative fluoroscopy times, length of hospital stay, cost of internal fixation, pre- and post-operative visual analogue scale(VAS) were compared between the two groups. The fracture reduction quality was evaluated according to the Matta criteria, and the clinical function was evaluated by the Majeed functional scoring system respectively.@*RESULTS@#All patients were followed up for 12 to 39(16.5±5.4) months after surgery. There was no statistically significant difference in the operation time, intraoperative blood loss, intraoperative fluoroscopy time, and length of hospital stay between the two groups(P>0.05). As for the cost of internal fixation, the cost of internal fixation in the screw group [2 914 (2 914, 4 371) yuan] was significantly lower than that of the INFIX group [6 205 (6 205, 6 205) yuan] (P<0.05). No significant difference was observed in the incidence of postoperative complications between the two groups (P>0.05). There was no significant difference in VAS assessment at admission, 1 week, and 3 months after surgery between the two groups(P>0.05). However, the VAS assessment at 1 week and 3 months after surgery of the two groups were significantly better than those at admission(P<0.05). There was no significant difference in the quality of fracture reduction after the operation and the efficacy evaluation at the last follow-up between the two groups(P>0.05).@*CONCLUSION@#For the treatment of fragility fractures, minimally invasive technology with trajectory screw fixation can achieve good clinical efficacy. It has the advantages of being relatively minimally invasive, less bleeding, relieving the pain. It deserves clinical application.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Perda Sanguínea Cirúrgica , Estudos de Casos e Controles , Fraturas Ósseas/cirurgia , Ossos Pélvicos/cirurgia , Estudos Retrospectivos
2.
China Journal of Orthopaedics and Traumatology ; (12): 646-649, 2021.
Artigo em Chinês | WPRIM | ID: wpr-888331

RESUMO

OBJECTIVE@#To evaluate the efficacy of iliolumbar fixation in the treatment of U-shaped sacral fractures.@*METHODS@#A retrospective study was conducted on the 14 complex U-shaped sacral fractures which had been treated from January 2014 to December 2019, involved 10 males and 4 females, aged 24 to 48 (35.4±6.5) years. Fracture healing time, nerve function, clinical function and complications were observed in the patients.@*RESULTS@#All patients were followed up for 9 to 16(26.0±5.9) months. The complete weight-bearing time for bone healing was(12.4±2.0) weeks. One case of surgical incision infection occurred after operation, and one case of sacrum nailspenetrated to the outer plate of sacrum. No complications such as pressure ulcers, loosening or rupture of internal fixation occurred. According to Gibbons scoring, the neurological function recovered from preoperative 2.9±0.9 to postoperative 2.1±1.1, there were statistically significant differences between preoperative and postoperative (@*CONCLUSION@#Sacral lumbar fixation is an effective method for the treatment of U-shaped sacrum fractures. It has the advantages of strong internal fixation and satisfactory functional recovery.


Assuntos
Feminino , Humanos , Masculino , Parafusos Ósseos , Fixação Interna de Fraturas , Estudos Retrospectivos , Sacro/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Resultado do Tratamento
3.
China Journal of Orthopaedics and Traumatology ; (12): 1042-1047, 2020.
Artigo em Chinês | WPRIM | ID: wpr-879349

RESUMO

OBJECTIVE@#To compare the clinical efficacy of three minimally invasive methods of anterior column screw, plate and screw rod system in the treatment of anterior pelvic ring fracture.@*METHODS@#From December 2015 to September 2018, 77 patients with pelvic anterior ring fracture were treated and followed up, including 45 males and 32 females, aged 19 to 73 years. According to AO / OTA classification, there were 26 cases of type B1, 20 cases of type B2, 17 cases of type B3 and 14 cases of type C. According to the different internal fixation methods, they were divided into three groups:anterior column screw group(35 cases), plate group(20 cases), and screw rod system group(22 cases). The operation time, intraoperative fluoroscopy times, blood loss, fracture reduction quality, complications and curative effect of the three groups were compared.@*RESULTS@#All 77 patients were followed up for 12 to 33 (16.5±5.7) months. The operation time, intraoperative blood loss and incision length of anterior column screw group were significantly shorter than those of plate group and screw rod system group, and intraoperative fluoroscopy times of plate group were significantly less than those of anterior column screw group and screw rod system group (@*CONCLUSION@#Minimally invasive internal fixation with anterior column screw, plate and screw rod system can obtain good clinical effect, but anterior column screw fixation has less trauma and lower incidence of surgicalcomplications.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas , Fraturas Ósseas/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos , Ossos Pélvicos/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
4.
China Journal of Orthopaedics and Traumatology ; (12): 228-231, 2018.
Artigo em Chinês | WPRIM | ID: wpr-690009

RESUMO

<p><b>OBJECTIVE</b>To study effect of shoulder joint function after rotator cuff repair of polylactic acid absorbable membrane.</p><p><b>METHODS</b>From September 2015 to December 2016, 50 patients diagnosed with rotator cuff tear were selected and divided into treatment group and control group. There were 25 patients in control group, including 12 males and 13 females, with an average age of (48.7±3.5) years old, who received simple arthroscopic rotator cuff repair. There were 25 patients in treatment group, including 11 males and 14 females, with an average age of(49.2±4.1) years old, who performed arthroscopic rotator cuff repair with implanting polylactic acid absorbable membraneon shoulder of rotator cuff. Preoperative and postoperative VAS score, ASES score and UCLA score were recorded and compared between two groups.</p><p><b>RESULTS</b>At 6 months after operation, preoperative VAS score in control group was 5.48±1.12, and decreased as 1.28±0.84 after operation; ASES score before operation was 52.24±4.64, and improved to 86.92±3.20 after operation;preoperative UCLA score improved from 14.36±1.89 before operation to 30.72±1.28 after operation. In treatment group, VAS score decreased from 5.36±1.32 before operation to 1.40±0.71 after operation;preoperative ASES score was 51.04±4.09, and improved to 88.96±2.79 after operation; UCLA score improved from 15.12±1.81 before operation to 32.12±1.33 after operation. There was no significant difference in VAS score between two groups, and ASES score, UCLA score in treatment group was obviously better than control group.</p><p><b>CONCLUSIONS</b>Application of polylactic acid absorbable medical membrane could obviously improve shoulder function, and effectively prevent acromion adhesion after arthroscopic rotator cuff repair.</p>


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Acrômio , Patologia , Artroscopia , Estudos de Casos e Controles , Poliésteres , Usos Terapêuticos , Polímeros , Amplitude de Movimento Articular , Manguito Rotador , Lesões do Manguito Rotador , Cirurgia Geral , Articulação do Ombro , Aderências Teciduais , Resultado do Tratamento