Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Tehran University Heart Center [The]. 2014; 9 (3): 137-139
em Inglês | IMEMR | ID: emr-161471

RESUMO

Atrioventricular groove rupture is a rare, albeit mortal, complication following mitral valve surgery. Avoidance is the best strategy but it cannot fully prevent the occurrence of this complication. Several repair techniques have been described with varying success rates; however, the rarity of the complication precludes consensus about the safest technique. Here we report two cases of posterior atrioventricular groove rupture. Both cases were diagnosed immediately after the cessation ofcardiopulmonarv bypass. Repair was performed successfully with a technique involving the use of biological glue. The postoperative course was uneventful for both of them. Both cases are well with normally functioning mitral prostheses: one with a follow-up time of 5.5 years and the other 10 months. We believe that the glue provides additional hemostasis and support to the repaired area

2.
Journal of Tehran University Heart Center [The]. 2012; 7 (4): 182-184
em Inglês | IMEMR | ID: emr-153387

RESUMO

A secundum atrial septal defect is the most common congenital heart defect. Transcatheter treatment of secundum atrial septal defects is a popular and less invasive alternative to surgery. Procedural complications may occur in a wide spectrum, particularly device embolus as the most emergent one, but luckily they do not commonly occur in the clinical setting. Mortality from adverse events related to transcatheter treatment strategies is twentyfold higher than that of primary elective surgical closure. Here, we report an Amplatzer device embolus in a secundum atrial septal defect patient. The device was successfully removed with surgery, postoperative course was uneventful, and the patient was discharged from the hospital on the 5[th] postoperative day

3.
Saudi Medical Journal. 2007; 28 (6): 844-847
em Inglês | IMEMR | ID: emr-163741

RESUMO

To examined the pre-and post-operative anti-HSP60 antibodies of serum from patients in preoperative sinus rhythm. We prospectively studied 45 consecutive patients admitted for elective CABG from 2004 to 2005. We randomly selected 10 patients developing AF [study sample [Group A]] and 10 postoperative patients without AF [control [Group B]. The study took place at the Department of Cardiovascular Surgery, Hacettepe University, Ankara, Turkey. Anti-HSP60 IgG value was 27.76 +/- 12.69 absorbance units [AU] in Group A preoperatively and decreased to 13.73 +/- 5.51 AU postoperatively. Controversially, preoperative value of anti-HSP60 IgG was 9.94 +/- 2.92 AU and decreased to 6.72 +/- 1.89 AU, postoperatively in Group B. Statistical analysis showed significant difference regarding preoperative anti-HSP60 IgG levels in Group A compared to Group B, which might be interpreted as an association between postoperative AF and preoperative levels of anti-HSP60 IgG. We provide the first evidence demonstrating the association of pre-and post-operative circulating anti-HSP60 antibodies with postoperative AF. These results suggest that serum HSP60 antibody levels may be a marker for subsequent development of AF

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA