Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Ocular Fundus Diseases ; (6): 675-680, 2023.
Artigo em Chinês | WPRIM | ID: wpr-995682

RESUMO

Objective:To investigate the risk factors of high intraocular pressure (IOP) after femtosecond laser in situ keratomileusis (FS-LASIK) in patients with high myopia, and construct and verify nomogram model.Methods:A retrospective clinical study. From January 2019 to January 2021, 327 patients (654 eyes) with high myopia treated with FS-LASIK in the Department of Ophthalmology of the 910th Hospital of the People's Liberation Army Coalition Security Force were included in the study. The patients were categorized into high IOP group and non-high IOP group according to whether high IOP occurred after surgery, which were 60 cases and 120 eyes (18.35%, 60/327) and 267 cases and 534 eyes (81.65%, 267/327), respectively. The clinical data of patients in the two groups were analyzed and observed, and the indicators with differences were subjected to one-way and multifactorial logistic regression analyses, and the results of the regression analyses were visualized to obtain the column line graphs using R3.5.3 software, and the accuracy of the column line graphs was verified by the consistency index (C-index), the calibration curves, and the subject's work characteristic curves (ROC curves).Results:Comparison of the number of cases of affected corneal thickness ( χ2=7.424), corneal curvature ( χ2=9.849), glucocorticoid treatment ( χ2=7.222), intraoperative IOP fluctuation ( χ2=11.475), corneal hysteresis ( χ2=6.368), and the incidence of intraoperative complications ( χ2=6.673) in the hypertensive IOP group and the nonvisualized IOP group were statistically significant ( P<0.05). Binary logistic regression analysis showed that corneal thickness >450 μm, corneal curvature≤38 D, glucocorticoid treatment, intraoperative IOP fluctuation, corneal hysteresis ≤8.0 mm Hg (1 mm Hg=0.133 kPa), and intraoperative complications were the risk factors for the occurrence of high IOP after FS-LASIK surgery in patients with high myopia ( P<0.05). The C-index of the column-line graph prediction model based on this was 0.722 (95% confidence interval 0.684-0.760), the calibration curve and the ideal curve were basically the same, and the area under the ROC curve was 0.709. Conclusions:Corneal thickness> 450 μm, keratometric curvature ≤38 D, glucocorticoid treatment, intraoperative fluctuation of intraocular pressure, and corneal hysteresis ≤8.0 mm Hg are the risk factors for the development of hyperopic IOP in highly risk factors for the development of high IOP after FS-LASIK surgery in myopic patients. The column-line diagram model constructed on the basis of the risk factors hava good accuracy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA